Subject: Civil Engineering Chapter: Advanced Surveying Topic: 21.1 Tacheometric Surveying
Tacheometric surveying, also called tacheometry or telemetry, is a branch of angular surveying in which both the horizontal distance and the vertical difference between two points are determined indirectly from instrumental observations made at one station, without the use of a measuring tape or chain. The word tacheometry is derived from the Greek words "tachys", meaning fast, and "metron", meaning measurement, which reflects the great speed with which this method can produce a plan or map. In this method a tacheometer, which is essentially a theodolite fitted with a stadia diaphragm, is used together with a levelling staff to take readings, and the distances are computed from these readings and the vertical angles observed.
The great advantage of tacheometry is that it eliminates the slow and laborious process of chain and tape measurement over rough and undulating ground. Wherever the terrain is steep, marshy, crossed by rivers or covered with dense vegetation, direct chaining becomes difficult or impossible, and tacheometric methods are employed instead. Because the instrument does the measuring, the field work is reduced to occupying a few stations and taking a series of readings, and a topographer can complete in hours what would otherwise take days. The method also provides a permanent record of observations from which distances can be computed or checked at any time, and it is therefore widely used in topographic surveys, in filling up the interior details of a survey, and in preparing contour maps.
In this chapter we will study the principles of tacheometry, the instruments used, the basic formula relating the staff intercept to the distance, and the various methods such as the stadia system, the tangential system and the subtense system. We will also examine the difference between the fixed hair method and the movable hair method, understand the constants of a tacheometer and how they are determined, and learn the common errors and precautions. The numerical problems in competitive examinations are based almost entirely on the stadia distance equation, so special attention is given to the derivation and application of the distance and elevation formulae.
The fundamental principle of tacheometry is based on the property of similar triangles. When a telescope with two stadia hairs is pointed at a levelling staff held vertically at some distance, the two stadia hairs intercept a certain length of the staff between them. Because the angle between the two lines of sight through the stadia hairs is constant for a given instrument, the length of the staff intercepted, called the staff intercept, is directly proportional to the distance of the staff from the instrument. This simple proportionality allows the distance to be computed from the staff intercept.
Consider the instrument at station P and the staff held vertically at point Q. Let the top stadia hair read the staff at A and the bottom stadia hair read it at B. The intercept AB is denoted by s. If the distance from the instrument to the staff is D, then for a horizontal sight the distance formula is D = k times s plus c, where k is the multiplying constant and c is the additive constant of the instrument. For a modern instrument with an anallactic lens, the additive constant c is made zero and the multiplying constant k is exactly 100, so that the formula reduces to D = 100 s. In this common case, the distance in metres is obtained by multiplying the staff intercept in metres by 100, or, if the staff intercept is read in centimetres, the distance is simply the number of centimetres expressed as metres.
The constant k, also called the stadia interval factor, is equal to the ratio of the focal length f of the objective to the distance i between the two stadia hairs, and it is generally kept equal to 100 by properly spacing the hairs. The additive constant c is equal to f plus d, where d is the distance from the objective to the vertical axis of the instrument, and it is reduced to zero by placing the anallactic lens at the proper position inside the telescope. For accurate work it is necessary to determine both constants by field observation before the instrument is used for tacheometric surveys, because the nominal values may be slightly different from the actual values.
There are three principal methods of tacheometric surveying, of which the stadia system is the most commonly used. In the stadia system, the tacheometer is fitted with a diaphragm carrying two additional horizontal hairs called stadia hairs, one above and one below the central horizontal hair, and equidistant from it. When the staff is sighted, the readings on the top and bottom stadia hairs are noted, and their difference gives the staff intercept s. This system may be employed in two ways: the fixed hair method, in which the stadia hairs are fixed in the diaphragm and the staff intercept varies with the distance, and the movable hair method, in which the stadia hairs are movable and are adjusted so that the intercept subtends a fixed value, the corresponding readings giving the distance.
In the tangential system, no stadia hairs are used. Instead, the vertical angles subtended by two points on the staff at known separations are measured by taking readings on two different vane targets. The distance is then computed by solving the triangle formed by the two rays. This system is not as accurate as the stadia system and is rarely used. In the subtense system, a horizontal subtense bar of exactly known length is set at one end of the line and the angle subtended by it at the instrument at the other end is measured. Since the length of the bar is known and the angle is measured, the distance is computed from the tangent relation; this method gives very accurate results and is useful for measuring long lines without tape.
The formulae for the inclined sights are the most important from the examination point of view. When the line of sight is inclined to the horizontal at a vertical angle theta, and the staff is held vertical, the horizontal distance is D = 100 s cos-squared theta plus c cos theta, and the vertical component V = 100 s sin theta cos theta plus c sin theta, where s is the staff intercept on the vertical staff. If the staff is held normal to the line of sight, the horizontal distance is D = 100 s cos theta plus c cos theta and the vertical component is V = 100 s sin theta. These formulae form the backbone of tacheometric numerical questions.
Example 1: A tacheometer with constants k = 100 and c = 0 is set up at a station P and a vertical staff is held at Q. The staff intercept is 0.375 m for a horizontal sight. Find the distance PQ.
Solution: For a horizontal sight, D = k times s plus c = 100 x 0.375 + 0 = 37.5 m. Hence the distance between the instrument station and the staff is 37.5 metres.
Example 2: A tacheometer with k = 100 and c = 0 is used with the staff held vertical. The observed intercept is 1.25 m and the vertical angle is 30 degrees. Find the horizontal distance and the vertical component.
Solution: For a vertical staff with an inclined sight, D = 100 s cos-squared theta = 100 x 1.25 x (cos 30) squared. Since cos 30 = 0.866, cos-squared theta = 0.75. Therefore D = 100 x 1.25 x 0.75 = 93.75 m. The vertical component V = 100 s sin theta cos theta = 100 x 1.25 x 0.866 x 0.5 = 54.125 m. Hence the horizontal distance is 93.75 m and the vertical component is 54.125 m.
Example 3: A tacheometer with k = 100 and c = 0 is sighted at a vertical staff held normal to the line of sight. The staff intercept is 0.80 m and the angle of elevation is 20 degrees. Compute the horizontal distance.
Solution: For a staff held normal to the line of sight, D = 100 s cos theta = 100 x 0.80 x cos 20 = 80 x 0.94 = 75.2 m. Hence the horizontal distance is 75.2 metres.
| Condition of sight | Horizontal distance D | Vertical component V |
|---|---|---|
| Horizontal sight, vertical staff | D = k s + c | V = 0 |
| Inclined sight, vertical staff | D = k s cos2 theta + c cos theta | V = k s sin theta cos theta + c sin theta |
| Inclined sight, staff normal to line | D = k s cos theta + c cos theta | V = k s sin theta |
| For anallactic instrument | D = 100 s (c = 0) | V = 100 s sin theta cos theta |
| Feature | Stadia system | Tangential system | Subtense system |
|---|---|---|---|
| Instrument required | Tacheometer with stadia hairs | Theodolite without stadia hairs | Theodolite with subtense bar |
| Staff intercept | Fixed hairs, variable intercept | Angles to fixed targets | Known bar length, measured angle |
| Accuracy | Good | Moderate | Very high |
| Use | Topographic and contour surveys | Special cases | Precise long-line measurement |
flowchart TD
A[Tacheometric Surveying] --> B[Principle of similar triangles]
A --> C[Instruments]
A --> D[Methods]
A --> E[Formulae]
C --> C1[Tacheometer]
C --> C2[Stadia diaphragm]
C --> C3[Levelling staff]
D --> D1[Stadia system]
D --> D2[Tangential system]
D --> D3[Subtense system]
D1 --> D1a[Fixed hair method]
D1 --> D1b[Movable hair method]
E --> E1[Horizontal sight: D = 100 s]
E --> E2[Inclined sight: D = 100 s cos2 theta]
E --> E3[Vertical: V = 100 s sin theta cos theta]
B --> B1[Staff intercept proportional to distance]
The following diagrams show the stadia principle and the geometry of an inclined tacheometric sight.
Tacheometric surveying is a rapid and convenient method of determining distances and differences in elevation by instrumental observation alone, without the use of a tape or chain. In this chapter we have studied the principle of similar triangles on which the method is based, the construction of the tacheometer and its stadia diaphragm, and the three systems of tacheometry: the stadia, tangential and subtense systems. We have derived the distance and elevation formulae for horizontal and inclined sights, examined the roles of the multiplying and additive constants, and solved numerical examples covering all three typical situations. The ability to apply the correct formula to the correct condition, and to handle the units carefully, is the key to scoring full marks in tacheometric questions. Because tacheometry is the quickest method of filling in topographic details and preparing contour plans, its principles remain relevant in all advanced surveying work, from total station surveys to digital terrain modelling.