Subject: Civil Engineering Chapter: Advanced Surveying Topic: 21.2 Stadia Method
The stadia method is the most widely used system of tacheometric surveying, in which the distance between the instrument station and the staff is determined by observing the length of staff intercepted between two horizontal stadia hairs of the diaphragm. The word "stadia" itself refers to the graduated staff used in this method, and by extension to the method of measurement itself. In this system the telescope of a tacheometer is provided with a diaphragm carrying two additional horizontal hairs, called stadia hairs, placed one above and one below the central horizontal hair and at equal distances from it. When the telescope is sighted on a staff held vertically at the point to be located, the two stadia hairs cut the staff at two different readings, and the difference of these readings is the staff intercept from which the distance is computed.
The stadia method is extremely popular because it combines speed with a level of accuracy that is adequate for most topographic and detail-survey purposes. It requires only a single set-up and two readings on the staff, and no chaining is necessary, so the work can proceed rapidly even over difficult ground. The method is used extensively for locating topographical details, preparing contour maps, measuring distances across water bodies and ravines, and in reconnaissance surveys. For competitive examinations the stadia method is the source of a large number of numerical questions, because the distance formulae, the constants of the instrument, and the difference between the fixed hair and movable hair systems are all favourite topics.
In this chapter we will study the two variants of the stadia method, namely the fixed hair method and the movable hair method, in detail. We will derive the stadia formula for horizontal sights and for inclined sights with both vertical and normal staff holding, understand the meaning of the stadia interval factor and the additive constant, and learn how these constants are determined in the field. We will also solve typical numerical problems and examine the sources of error and the precautions to be observed, so that the student can answer both conceptual and computational questions with confidence.
In the fixed hair method, the stadia hairs are fixed in position in the diaphragm, so the angle between the top and bottom stadia rays is constant for the instrument. When a staff is sighted, the interval intercepted by the fixed hairs, that is, the staff intercept s, varies with the distance of the staff from the instrument: the nearer the staff, the smaller the intercept, and the farther the staff, the larger the intercept. The distance is then computed by multiplying the intercept by the stadia interval factor and adding the additive constant. This is the method in normal use, because it requires no adjustment of the diaphragm and only a simple subtraction of two readings.
In the movable hair method, the stadia hairs are not fixed but can be moved by means of a micrometer screw. The hairs are set so that they enclose a staff intercept that is a fixed convenient value, such as one metre or one-half metre, no matter what the distance of the staff may be. When the staff intercept is fixed, the distance becomes a function of the separation of the hairs, and the distance is read from the micrometer scale. The movable hair method gives more precise results than the fixed hair method because the observer can set the hairs exactly on a whole number of graduations, but it is slower in operation and is therefore used where greater accuracy is required, such as in precise traverse work.
Both methods depend on the same principle: the angle between the lines of sight through the two stadia hairs is fixed, so the ratio of the staff intercept to the distance is constant. In the fixed hair method we keep the angle fixed and measure the intercept; in the movable hair method we keep the intercept fixed and measure the angle, that is, the separation of the hairs. Either way, the same fundamental relation connects the intercept, the distance and the constants of the instrument.
Let f be the focal length of the objective lens, i the distance between the two stadia hairs, and d the distance from the objective to the vertical axis of the instrument. When the staff is held at a distance D from the instrument axis and the sight is horizontal, the stadia formula is D = (f/i) s + (f + d), where s is the staff intercept. The ratio f/i is called the stadia interval factor or the multiplying constant k, and it is usually made equal to 100 by spacing the hairs so that i = f/100. The quantity (f + d) is called the additive constant c, and it is usually made equal to zero by the use of an anallactic lens, which is placed inside the telescope at such a position that the second principal point coincides with the vertical axis of the instrument.
For an anallactic tacheometer, therefore, the distance formula reduces to the extremely convenient form D = 100 s for a horizontal sight. When the line of sight is inclined at a vertical angle theta to the horizontal and the staff is held vertical, the horizontal distance is D = 100 s cos-squared theta and the vertical component is V = 100 s sin theta cos theta. When the staff is held normal to the line of sight, the horizontal distance is D = 100 s cos theta and the vertical component is V = 100 s sin theta. These are the standard equations that must be memorised for the examination.
The stadia interval factor k and the additive constant c are not always equal to their nominal values, so they should be determined by field observation. The factor k is determined by measuring a base line of known length, holding the staff at different known distances, and computing k from the intercepts; taking the mean of several observations gives a reliable value. The additive constant is determined similarly by solving the distance equation for c using two known distances. An accurate value of k is essential because even a small error in the factor is multiplied by every intercept measured in the survey.
Example 1: A stadia diaphragm of a tacheometer has stadia hairs spaced 4 mm apart, and the focal length of the objective is 200 mm. Find the multiplying constant.
Solution: The multiplying constant k = f/i = 200/4 = 50. Hence the stadia interval factor is 50.
Example 2: An anallactic tacheometer with k = 100 is sighted on a vertical staff held at a distant point. The staff intercept is 1.6 m and the vertical angle is 45 degrees. Find the horizontal distance and the vertical component.
Solution: For a vertical staff, D = 100 s cos-squared theta = 100 x 1.6 x cos-squared 45. Since cos 45 = 0.7071, cos-squared 45 = 0.5. Therefore D = 100 x 1.6 x 0.5 = 80 m. The vertical component V = 100 s sin theta cos theta = 100 x 1.6 x 0.7071 x 0.7071 = 80 m. Hence both the horizontal distance and the vertical component are 80 m.
Example 3: A tacheometer with k = 100 and c = 0 is used with the staff held normal to the line of sight at an angle of depression of 15 degrees. The staff intercept is 0.60 m. Compute the horizontal distance and the vertical component.
Solution: D = 100 s cos theta = 100 x 0.60 x cos 15 = 60 x 0.9659 = 57.95 m. V = 100 s sin theta = 60 x sin 15 = 60 x 0.2588 = 15.53 m. Hence the horizontal distance is 57.95 m and the vertical component is 15.53 m.
| Sighting condition | Staff position | Horizontal distance | Vertical component |
|---|---|---|---|
| Horizontal | Vertical | D = 100 s | 0 |
| Inclined | Vertical | D = 100 s cos2 theta | V = 100 s sin theta cos theta |
| Inclined | Normal to line | D = 100 s cos theta | V = 100 s sin theta |
| Inclined (non-anallactic) | Vertical | D = k s cos2 theta + c cos theta | V = k s sin theta cos theta + c sin theta |
| Feature | Fixed hair method | Movable hair method |
|---|---|---|
| Stadia hairs | Fixed in diaphragm | Movable by micrometer screw |
| Intercept | Varies with distance | Kept at fixed value |
| Distance determination | Multiply intercept by k | Read from micrometer scale |
| Speed | Faster | Slower |
| Accuracy | Moderate | Higher |
| Common use | Topographic and detail survey | Precise traverse work |
flowchart TD
A[Stadia Method] --> B[Fixed hair method]
A --> C[Movable hair method]
A --> D[Instrumental constants]
A --> E[Distance formulae]
B --> B1[Constant angle, variable intercept]
B --> B2[Distance = k s + c]
C --> C1[Fixed intercept, variable hair separation]
C --> C2[Distance from micrometer]
D --> D1[Multiplying constant k = f/i]
D --> D2[Additive constant c = f + d]
E --> E1[Horizontal: D = 100 s]
E --> E2[Vertical staff: D = 100 s cos2 theta]
E --> E3[Normal staff: D = 100 s cos theta]
The following diagrams illustrate the stadia diaphragm and the inclined sight geometry of the stadia method.
The stadia method is the backbone of tacheometric surveying and the most frequently examined topic in advanced surveying. In this chapter we have studied the two forms of the method, the fixed hair method and the movable hair method, understood the construction of the stadia diaphragm, and derived the distance formulae for horizontal and inclined sights under both vertical and normal staff holding. We have examined the stadia interval factor k = f/i and the additive constant c = f + d, learnt that an anallactic lens makes c equal to zero, and solved numerical examples covering the typical questions asked in competitive examinations. The stadia method demonstrates clearly how a surveyor can obtain distances and elevations from a single set-up, which is why it remains in use even in the age of total stations. A firm grasp of the stadia formulae, together with careful handling of units and angles, will enable the candidate to answer both the conceptual and the numerical questions on this topic accurately and quickly.