Subject: Civil Engineering Chapter: Concrete Technology Topic: 8.4 Workability of Concrete
Workability is the property of fresh concrete that describes the ease with which it can be mixed, transported, placed and compacted without segregation or bleeding, and it is one of the most important properties of green concrete because it decides whether the concrete can be handled efficiently at the site. A concrete mix must be workable enough to flow into all the corners of the formwork and around the reinforcement, yet it must not be so wet that it segregates and loses its homogeneity. The correct degree of workability depends on the type of construction, the reinforcement density, the method of compaction and the shape and size of the structural member.
Workability is not a single physical property but a combined effect of several properties of the fresh concrete, including consistency, mobility and compactibility. Consistency is the wetness or fluidity of the mix, mobility is the ease of movement of the concrete, and compactibility is the ease with which the concrete can be compacted to its maximum density. Because workability cannot be measured directly, it is measured through these related properties by means of standard laboratory and field tests, each of which gives an indirect measure of the ease of handling.
In this chapter we will study the factors that affect the workability of concrete, the standard methods of measuring it, namely the slump test, compaction factor test, Vee-Bee consistometer test and flow table test, and the selection of the appropriate workability for different situations. The numerical values associated with each test, such as the slump ranges for different workability classes and the compaction factor values, are frequently asked in examinations and are presented in the revision tables.
The most important factor affecting the workability of concrete is the water content of the mix. A higher water content gives a wetter and more workable concrete, which is why the slump increases with the water-cement ratio. The water content, not the water-cement ratio by itself, is the controlling factor for workability, because for the same water-cement ratio, a mix with a higher cement content has more paste and is more workable. The workability therefore increases with the paste content, and lean mixes with less cement paste are harsh and difficult to work.
The properties of the aggregates also influence the workability. Rounded aggregates with a smooth surface require less water for the same workability than angular and flaky aggregates, because the angular particles interlock and offer more surface area to be wetted. A well-graded aggregate with a continuous range of sizes gives better workability than a poorly graded aggregate with gaps, because the voids are smaller and the paste can lubricate the particles more effectively. The maximum size of the aggregate also matters, since a larger maximum size reduces the surface area and the water demand for the same workability.
The type and quantity of cement, the temperature of the mix and the use of admixtures all affect the workability. An increase in temperature reduces the workability because the hydration proceeds faster and the water is consumed more quickly, and concrete placed in hot weather loses its slump rapidly. Plasticizers and superplasticizers improve the workability dramatically without adding water, air-entraining agents improve the workability by introducing tiny air bubbles that act as ball bearings between the particles, and a mix with a higher cement content is more workable because of the larger volume of paste.
The slump test is the simplest and most widely used test for workability, and it is carried out with a standard slump cone of height 300 mm, top diameter 100 mm and base diameter 200 mm. The cone is filled with concrete in four layers, each compacted with 25 strokes of a tamping rod, and the cone is then lifted vertically. The slump is the difference between the height of the cone and the height of the concrete after subsidence, measured in millimetres. The slump may be a true slump, where the concrete subsides evenly, a shear slump, where one part slides past the other, or a collapse slump, where the concrete collapses completely; only the true slump is a reliable measure, and a shear or collapse slump indicates a harsh or over-wet mix. The slump test measures the consistency and not the workability as such, and it is suitable for medium workability mixes.
The compaction factor test measures the workability of concrete by determining the degree of compaction achieved by a standard amount of work, and it is more sensitive than the slump test for dry and stiff mixes. The apparatus consists of two hoppers and a cylinder; the concrete is allowed to fall freely from the upper hopper into the lower hopper and then into the cylinder, and the compaction factor is the ratio of the weight of the partially compacted concrete to the weight of the fully compacted concrete. The compaction factor normally lies between 0.85 and 0.98, with higher values indicating higher workability, and this test is preferred for low to medium workability mixes.
The Vee-Bee consistometer test measures the time in seconds required for a concrete cone to be completely remoulded under vibration, and it is used for very stiff mixes such as those compacted by vibrators. The concrete is placed in the Vee-Bee apparatus, a transparent disc is lowered onto the surface, and the apparatus is vibrated until the disc touches the full surface of the concrete; the time recorded is called the Vee-Bee time. A Vee-Bee time of about 2 seconds indicates a very high workability, 5 seconds a medium workability and 20 seconds a very low workability. The flow table test is used for very high workability mixes, where the flow of the concrete on a dropped table is measured as the percentage increase in diameter of the pat of concrete.
The required workability of concrete depends on the type of construction, the section size, the spacing of the reinforcement and the method of compaction. For mass concrete and lightly reinforced sections compacted by vibration, a low workability with a slump of 25 to 75 mm and a compaction factor of 0.85 is adequate. For heavily reinforced sections, thin sections and concrete placed in narrow formwork, a medium to high workability with a slump of 75 to 125 mm is required so that the concrete can flow around the reinforcement and fill the corners.
For concrete placed by pumps, a very high workability with a slump of 100 to 150 mm or more is required, because the concrete must flow through the pipeline under pressure without blocking. For concrete compacted by vibration, lower slumps can be used because the vibrator provides the additional work of compaction, while for hand-compacted concrete a higher workability is needed. In hot weather, the workability falls rapidly, so the mix is designed with a slightly higher initial slump or retarders are used to delay the setting.
The choice of the workability test also depends on the class of workability. Very low and low workability mixes are best tested by the compaction factor or Vee-Bee test, medium workability mixes by the slump test, and high workability mixes by the flow table test. The slump test is the most common test in practice, but the compaction factor test is regarded as the most accurate test for the workability of concrete, and this distinction is frequently examined.
| Workability | Slump (mm) | Compaction factor | Vee-Bee time (sec) |
|---|---|---|---|
| Very low | 0-25 | 0.78-0.85 | Above 12 |
| Low | 25-50 | 0.85-0.92 | 8-12 |
| Medium | 50-100 | 0.92-0.95 | 5-8 |
| High | 100-150 | 0.95-0.98 | 2-5 |
| Very high | Above 150 | Above 0.98 | Below 2 |
| Type of work | Slump (mm) |
|---|---|
| Mass concrete, foundations | 25-50 |
| Reinforced concrete slabs, beams, columns | 50-100 |
| Thin sections, heavily reinforced | 75-125 |
| Concrete pumped through pipes | 100-150 |
| Trench fill, simple footings | 25-75 |
flowchart TD
A[Workability of Concrete] --> B[Definition]
A --> C[Factors affecting]
A --> D[Slump test]
A --> E[Compaction factor test]
A --> F[Vee-Bee test]
A --> G[Flow table test]
B --> B1[Ease of mixing and placing]
B --> B2[No segregation or bleeding]
C --> C1[Water content]
C --> C2[Aggregate grading and shape]
C --> C3[Cement content and admixtures]
C --> C4[Temperature]
D --> D1[Slump cone 300 mm high]
D --> D2[True, shear, collapse slump]
E --> E1[Ratio of partial to full compaction]
E --> E2[Most accurate test]
F --> F1[Time in seconds]
F --> F2[For stiff mixes]
G --> G1[Flow percentage]
A --> H[Selection by construction type]
The following diagrams show the slump cone test arrangement with the different types of slump and the compaction factor test apparatus.
Workability is the property that decides how easily fresh concrete can be handled, and it must be matched carefully with the type of construction, the density of reinforcement and the method of compaction. In this chapter we have studied the meaning of workability and its components of consistency, mobility and compactibility, the factors that control it such as water content, aggregate grading, cement content, admixtures and temperature, and the four standard tests, namely the slump test, the compaction factor test, the Vee-Bee consistometer test and the flow table test. The numerical ranges of the slump, the compaction factor and the Vee-Bee time for the different workability classes have been presented, together with the guidance for selecting the workability for different works. The candidate must remember that workability is a property of the fresh concrete, that it conflicts with the strength requirement because both depend on the water content, and that the proper test must be chosen for the proper class of workability. With these concepts clear, the candidate is ready to study how the ingredients are proportioned in concrete mix design, which is the subject of the next chapter.