Subject: Civil Engineering Chapter: Concrete Technology Topic: 8.5 Concrete Mix Design
Concrete mix design is the process of selecting the most economical proportions of cement, fine aggregate, coarse aggregate and water to produce a concrete of the required strength, workability and durability. The aim of mix design is not merely to satisfy the strength requirement, but to do so with the minimum possible cement content, because cement is the most expensive ingredient of concrete. The proportions are chosen so that the concrete meets the characteristic compressive strength with the required margin, is workable enough to be placed and compacted, and is durable in the environment in which it will serve.
The mix design is expressed in two ways. A nominal mix is a proportion-based mix such as 1:2:4 or 1:1.5:3, which fixes the ratio of cement, fine aggregate and coarse aggregate by volume, and it is used for small and unimportant works. A designed mix is a mix in which the proportions are determined by laboratory trials based on the properties of the actual materials, the target strength and the exposure conditions, and it is used for all important works and for concrete of grades M25 and above. The nominal mixes are specified in IS 456 for grades up to M20.
In this chapter we will study the concept of the characteristic strength and the target mean strength, the steps of the mix design procedure of IS 10262, the selection of the water-cement ratio, the estimation of the water and cement contents, the determination of the aggregate proportions, and the method of trial mixing and adjustment. The grades of concrete, the standard deviation, and the target strength formula are the most frequently tested items in this topic and are emphasised throughout.
Concrete is classified into grades on the basis of its characteristic compressive strength at 28 days. The characteristic strength f(ck) is the value of the compressive strength below which not more than 5 percent of the test results are expected to fall, and it is the specified design strength of the concrete. The grades are designated by the letter M followed by the characteristic strength in N/mm2, such as M15, M20, M25, M30, M35, M40 and so on. The ordinary grades M10, M15 and M20 are used for foundations, mass concrete and lightly loaded members, while the standard grades M25 to M55 are used for reinforced concrete members, and the higher grades M60 and above are high strength concrete.
The concrete is accepted or rejected on the basis of the characteristic strength, and the sample test results are compared with the specified strength using the statistical acceptance criteria of IS 456. The strength of concrete varies from sample to sample due to variations in the materials, the batching, the compaction and the curing, and this variation is measured by the standard deviation. The target mean strength f(m) is the strength that the mix is designed to achieve, and it is higher than the characteristic strength to allow for the variability, being calculated as f(m) = f(ck) + 1.65 times the standard deviation, where 1.65 is the value of the normal distribution corresponding to a 5 percent probability of failure.
The value of the standard deviation depends on the quality control exercised on the site. For a good quality control, the standard deviation for concrete of grade M20 to M35 is about 4 to 5 N/mm2, and the tables of IS 10262 provide the assumed standard deviations for design purposes. A well-controlled site with a lower standard deviation can design the mix with a smaller margin, saving cement, while a poorly controlled site must use a larger margin. The grade of concrete also decides the minimum cement content and the maximum water-cement ratio for durability, which are given in the exposure tables of IS 456.
The mix design procedure of IS 10262 proceeds through a sequence of steps. The first step is the collection of the data, namely the characteristic strength, the degree of workability, the exposure condition, the maximum size of aggregate, and the properties of the materials including the specific gravities and the grading of the aggregates. The second step is the selection of the target mean strength using the formula f(m) = f(ck) + 1.65 s, where s is the standard deviation from the tables of IS 10262 or from the actual site records.
The third step is the selection of the water-cement ratio for the target mean strength, using the strength-water cement ratio relationship of the actual materials, and this ratio is then checked against the maximum value permitted for the exposure condition from IS 456, with the lower of the two values adopted. The fourth step is the estimation of the water content for the required workability and the maximum size of aggregate, from the table of IS 10262, followed by its adjustment for the slump, the shape of the aggregate and the use of admixtures. The fifth step is the calculation of the cement content by dividing the water content by the water-cement ratio, and this cement content is checked against the minimum cement content required for durability.
The sixth step is the determination of the proportions of the coarse and fine aggregates from the water-cement ratio, the maximum size of aggregate, the fineness modulus of the fine aggregate and the workability. The total aggregate volume is found by subtracting the volumes of the water and cement from the unit volume of concrete, and this total aggregate is then divided between the coarse and fine aggregate using the table of volume of coarse aggregate per unit volume of total aggregate. Finally, trial mixes are prepared, tested for workability and strength, and the proportions are adjusted until the concrete meets the requirements.
Consider the design of an M25 concrete for moderate exposure with a target slump of 75 mm, using a maximum aggregate size of 20 mm and an assumed standard deviation of 4 N/mm2. The target mean strength is f(m) = 25 + 1.65 x 4 = 31.6 N/mm2. From the strength relationship, a water-cement ratio of about 0.45 gives this strength, and since 0.45 is also the maximum allowed for moderate exposure, the water-cement ratio of 0.45 is adopted. From the tables of IS 10262, the water content for a 20 mm aggregate and 75 mm slump is about 186 kg per cubic metre, so the cement content is 186/0.45 = 413 kg per cubic metre, which exceeds the minimum cement content of 300 kg per cubic metre for moderate exposure.
The total aggregate volume is calculated as 1 cubic metre minus the volumes of water and cement, which are 0.186 cubic metres and 0.413/3.15 = 0.131 cubic metres respectively, giving a total aggregate volume of about 0.683 cubic metres. The volume of coarse aggregate is read from the table for a water-cement ratio of 0.45 and a 20 mm aggregate, giving a value of about 0.62 of the total aggregate, so the fine aggregate is 0.38. The weights of the aggregates are then found by multiplying the volumes by the specific gravities and the unit weights. This produces the first trial mix, which is tested for slump and strength.
The trial mixes are the final check of the design. At least three trial mixes are prepared with the calculated proportions, and the workability is checked by the slump or compaction factor test. The concrete is cast into cubes and tested at 7 and 28 days, and the 28-day strength is compared with the target mean strength. If the strength is low, the water-cement ratio is reduced or the cement content is increased, and if the workability is inadequate, the water content or the admixture dosage is adjusted. The mix that satisfies both the strength and the workability requirements with the minimum cement content is adopted for the work.
| Grade | Characteristic strength (N/mm2) | Typical use |
|---|---|---|
| M10 | 10 | Mass concrete, PPC foundations |
| M15 | 15 | Lean concrete, plain concrete |
| M20 | 20 | General RCC work, nominal mix 1:1.5:3 |
| M25 | 25 | Design mix, beams, columns, slabs |
| M30-M40 | 30-40 | Heavily loaded structures |
| M50-M60 | 50-60 | High strength, prestressed concrete |
| Step | Quantity | Value |
|---|---|---|
| Target mean strength | f(ck) + 1.65 s | 31.6 N/mm2 |
| Water-cement ratio | From strength and durability | 0.45 |
| Water content | For 20 mm aggregate, 75 mm slump | 186 kg/m3 |
| Cement content | Water / w-c ratio | 413 kg/m3 |
| Total aggregate volume | 1 - V(water) - V(cement) | 0.683 m3 |
| Coarse aggregate fraction | Table for 20 mm aggregate | 0.62 |
| Fine aggregate fraction | 1 - coarse fraction | 0.38 |
flowchart TD
A[Concrete Mix Design] --> B[Characteristic strength]
A --> C[Target mean strength]
A --> D[Nominal mix]
A --> E[Designed mix]
A --> F[IS 10262 procedure]
A --> G[Trial mixes]
B --> B1[f(ck) below 5 percent of results]
B --> B2[Grades M10 to M60]
C --> C1[f(m) = f(ck) + 1.65 s]
C --> C2[Depends on standard deviation]
D --> D1[1:2:4 for M15]
D --> D2[1:1.5:3 for M20]
F --> F1[Select water-cement ratio]
F --> F2[Estimate water content]
F --> F3[Calculate cement content]
F --> F4[Proportion aggregates]
G --> G1[Test workability]
G --> G2[Test 28-day strength]
G --> G3[Adjust proportions]
F --> H[Check minimum cement for durability]
The following diagrams show the normal distribution of concrete strength and the flow of the mix design procedure.
Concrete mix design is the scientific method of proportioning the ingredients of concrete to achieve the required strength, workability and durability with economy. In this chapter we have studied the concept of the characteristic strength and the grades of concrete, the calculation of the target mean strength with the standard deviation, the step-by-step procedure of IS 10262 for designed mixes, and the role of the trial mixes in verifying the design. The distinction between nominal mixes, which are used for small works up to M20, and designed mixes, which are used for important works, has been made clear. The two controlling checks of the design, namely the maximum water-cement ratio and the minimum cement content for durability, have been emphasised because they are the most frequently tested aspects. A candidate who understands the mix design procedure, the strength statistics and the durability requirements will be able to solve both the numerical and the theoretical questions on this topic, and will be well prepared to study the batching, mixing and transportation of the designed concrete in the next chapter.