Subject: Civil Engineering Chapter: Concrete Technology Topic: 8.8 Concrete Testing
The testing of concrete is essential to verify that the concrete produced on the site has the strength, workability and durability for which it was designed, and to control the quality of the construction. Testing is carried out on both the fresh and the hardened concrete. The tests on fresh concrete, such as the slump test and the compaction factor test, check the workability at the time of placing, while the tests on hardened concrete, such as the compressive strength test, the split tensile test and the flexural test, check the strength and the other properties of the material that will carry the loads. Every important concrete structure requires a programme of testing which follows the procedures and the acceptance criteria of IS 456 and the relevant test codes.
The compressive strength test is the most important test on hardened concrete, because the grade of the concrete is defined by its compressive strength and because the compressive strength correlates well with the other properties of the concrete. The test is performed on cubes of 150 mm side or on cylinders of 150 mm diameter and 300 mm height, which are cast, cured and tested at the specified age, normally 28 days, and the results are compared with the acceptance criteria of the code. The number of cubes to be cast, the frequency of testing and the evaluation of the results are all prescribed by IS 456.
In this chapter we will study the standard tests on fresh and hardened concrete, including the compressive strength test on cubes and cylinders, the split tensile test, the flexural test, the non-destructive tests such as the rebound hammer and the ultrasonic pulse velocity test, and the acceptance criteria of the concrete according to IS 456. The dimensions of the test specimens, the rate of loading, the correction factors and the acceptance conditions are the most frequently examined details.
The compressive strength test is carried out on concrete cubes of 150 mm side, which are the standard specimens for the acceptance of concrete in India. The cubes are cast in moulds of non-absorbent material, filled in layers of 50 mm, each layer compacted by 25 strokes of a 16 mm tamping rod or by vibration, and the specimens are then covered and kept in the mould for 24 hours. The cubes are removed from the moulds and cured in water at a temperature of 27 plus or minus 2 degrees Celsius until the time of the test. The cubes are tested at 7 days and 28 days in a compression testing machine, with the load applied on the two opposite faces at a rate of 14 N/mm2 per minute, and the compressive strength is the load at failure divided by the area of the face.
The results of the cube test depend on the size and shape of the specimen, the curing and the rate of loading. A 100 mm cube gives a slightly higher strength than a 150 mm cube, so the strength of a 100 mm cube is reduced by a factor of 0.9 when it is reported as the equivalent 150 mm cube strength. The cylinder strength is lower than the cube strength because the shape affects the failure pattern; the ratio of the cylinder strength to the cube strength is about 0.8 for normal concrete. The rate of loading also matters, since a faster rate of loading gives a higher measured strength.
The characteristic compressive strength of the concrete is evaluated from the cube results using the statistical criteria of IS 456. A sample of concrete is tested in sets of 3 cubes, and the acceptance criteria state that the average of a group of four consecutive non-overlapping samples must not be less than f(ck) plus 0.825 times the standard deviation, and that every individual test result must not be less than f(ck) minus 3 N/mm2 or minus 0.15 times f(ck), whichever is greater. The standard deviation is computed from the test records, and these criteria ensure that the concrete delivered to the site has the required characteristic strength.
The tensile strength of concrete is measured by the split tensile test, which is carried out on cylinders of 150 mm diameter and 300 mm height. The cylinder is placed horizontally in the testing machine between two loading strips, and a compressive load is applied along the length of the cylinder until it fails by splitting along the vertical diameter. The split tensile strength is calculated as T = 2P / (pi D L), where P is the load at failure, D is the diameter and L is the length of the cylinder. The split tensile strength of concrete is about one tenth of the compressive strength, and it is used in the design of concrete pavements, in the study of cracking and in the assessment of the bond.
The flexural strength, also called the modulus of rupture, is measured by the flexural test on a beam of 150 mm square section and 700 mm length, or on a beam of 100 mm square section and 500 mm length. The beam is simply supported over a span and loaded at the third points in the two-point loading method, which is the standard arrangement, and the flexural strength is calculated as f(b) = P L / (b d squared), where P is the load at failure, L is the span, b is the width and d is the depth of the beam. When the beam fails at the centre within the middle third, this formula is used, and the flexural strength of concrete is about one seventh to one eighth of the compressive strength.
The modulus of elasticity of concrete is determined by the stress-strain test on a cylinder, in which the deformation of the cylinder is measured at intervals as the load is increased, and the modulus is the slope of the stress-strain curve. The static modulus of elasticity is calculated as E = stress / strain over the elastic range, and the code gives the relation E = 5000 sqrt(f(ck)) in N/mm2 for normal weight concrete. This modulus is used in the calculation of the deflection of beams and the shortening of columns, and it increases with the compressive strength and the density of the concrete.
The non-destructive tests are used to assess the quality of the concrete in an existing structure without damaging it, and they are used to check the uniformity, the strength and the presence of internal cracks and voids. The rebound hammer test, also called the Schmidt hammer test, measures the rebound of a spring-loaded hammer when it strikes the surface of the concrete, and the rebound number is correlated with the compressive strength through calibration curves. The rebound hammer measures the surface hardness of the concrete, and it is affected by the surface moisture, the carbonation and the local aggregate, so it gives only an approximate estimate of the strength.
The ultrasonic pulse velocity test measures the time taken by an ultrasonic pulse to travel through the concrete, and the pulse velocity is computed as the path length divided by the transit time. A higher pulse velocity indicates denser and better quality concrete, while a low velocity indicates voids, cracks or poor quality concrete. According to the standard classification, a pulse velocity above 4.5 km/s indicates excellent quality, 3.5 to 4.5 km/s indicates good quality, 3.0 to 3.5 km/s indicates medium quality, and below 3.0 km/s indicates doubtful or poor quality. The ultrasonic pulse velocity test is used to detect internal cracks, honeycombing and the effects of fire damage.
The non-destructive tests are often used together, with the rebound hammer and the ultrasonic pulse velocity test combined to estimate the strength of the concrete in a structure, and they may be supported by cores drilled from the structure which are tested in compression to obtain the actual strength. The core test is a semi-destructive test, in which a core of 75 to 100 mm diameter is drilled from the structure and tested in compression, and the core strength is compared with the specified strength to judge the acceptance of the concrete. The location, the number and the evaluation of the cores are prescribed in the codes, and the core test is the most direct method of assessing the in-situ strength.
| Test | Specimen | Size | Typical result |
|---|---|---|---|
| Compressive strength | Cube | 150 mm side | Characteristic strength f(ck) |
| Compressive strength | Cylinder | 150 x 300 mm | About 0.8 times cube |
| Split tensile | Cylinder | 150 x 300 mm | About 1/10 of compressive |
| Flexural strength | Beam | 150 x 150 x 700 mm | About 1/7 to 1/8 of compressive |
| Rebound hammer | Existing surface | Contact point | Correlated to strength |
| Ultrasonic pulse | Existing member | Two probes | Velocity above 4.5 km/s excellent |
| Condition | Requirement |
|---|---|
| Average of 4 consecutive samples | Not less than f(ck) + 0.825 s |
| Individual test result | Not less than f(ck) - 3 N/mm2 |
| Alternative individual criterion | Not less than 0.85 f(ck) |
| Cube size correction (100 mm cube) | Multiply strength by 0.9 |
| Rate of loading | 14 N/mm2 per minute |
flowchart TD
A[Concrete Testing] --> B[Fresh concrete tests]
A --> C[Hardened concrete tests]
A --> D[Non-destructive tests]
B --> B1[Slump test]
B --> B2[Compaction factor test]
C --> C1[Compressive cube test]
C --> C2[Split tensile test]
C --> C3[Flexural test]
C --> C4[Modulus of elasticity]
D --> D1[Rebound hammer]
D --> D2[Ultrasonic pulse velocity]
D --> D3[Core test]
C1 --> E[150 mm cube, 28 days]
C1 --> F[Acceptance criteria f(ck) + 0.825 s]
C2 --> G[T = 2P / pi D L]
C3 --> H[f(b) = P L / b d squared]
A --> I[Quality control and acceptance]
The following diagrams show the compression testing of a cube and the arrangement of the flexural test on a beam.
The testing of concrete is the link between the design and the actual construction, because it verifies that the concrete placed in the structure has the properties for which it was designed. In this chapter we have studied the standard tests on fresh concrete, the compressive strength test on cubes and cylinders with the curing and loading conditions, the split tensile and flexural tests for the tensile properties, the determination of the modulus of elasticity, and the non-destructive tests including the rebound hammer, the ultrasonic pulse velocity test and the core test. The dimensions of the specimens, the correction factors, the rate of loading and the acceptance criteria of IS 456 have been presented in detail, because these small numerical facts are the core of the examination questions on this topic. The candidate must remember that the quality of the concrete is judged by the statistical acceptance of the cube results, and that the non-destructive tests are used to assess the concrete in existing structures. With this knowledge of testing, the candidate is ready to study the durability of concrete, which determines how long the tested concrete will last in service.