Subject: Civil Engineering Chapter: Concrete Technology Topic: 8.10 Special Concrete
Ordinary concrete of the conventional ingredients has many excellent properties, but its range of applications is limited by its low tensile strength, its large self-weight, its poor resistance to cracks and its inability to meet the special requirements of modern structures. To overcome these limitations, many special concretes have been developed, each designed for a particular purpose or a particular set of properties. These include high strength concrete, high performance concrete, fibre reinforced concrete, self compacting concrete, lightweight concrete, ferrocement, polymer concrete, ready mixed concrete, shotcrete, roller compacted concrete and expansive concrete, and each has its own composition, properties and applications.
The special concretes can be grouped according to the property they improve. High strength and high performance concretes improve the strength and the durability, fibre reinforced concrete improves the toughness and the resistance to cracking, lightweight concrete reduces the self-weight, self compacting concrete eliminates the need for vibration, ferrocement provides thin and strong elements, polymer concrete improves the resistance to chemicals, and ready mixed concrete and shotcrete improve the methods of production and placing. The selection of the special concrete for a given job depends on the requirements of the structure and the cost of the material.
In this chapter we will study the composition, the properties and the applications of the most important special concretes, with particular attention to the fibre reinforced concrete, the self compacting concrete, the lightweight concrete, the high strength concrete and the ferrocement. The standard proportions, the characteristic properties such as the compressive strength, the density and the workability, and the typical applications of each special concrete are the most frequently tested items in this topic.
High strength concrete is the concrete with a characteristic compressive strength of 60 MPa or more, which is obtained by using a low water-cement ratio, a high cement content, the superplasticizers and the mineral admixtures such as silica fume and fly ash. The low water-cement ratio reduces the porosity and gives a very dense paste, while the superplasticizer makes the stiff mix workable, and the silica fume fills the micro-pores between the cement particles. High strength concrete is used for the columns of tall buildings, where the reduced cross-section saves space and self-weight, and for the long-span bridges and the prestressed concrete elements.
High performance concrete is a broader concept than high strength concrete, because it is the concrete designed to have certain performance characteristics, such as a high strength, a high durability, a low permeability, a high modulus of elasticity or a high resistance to abrasion, as required by the specific application. High performance concrete is used in the marine structures, the nuclear power plants, the bridge decks and the structures exposed to the aggressive environments, where the durability requirements are as important as the strength. The use of the mineral admixtures and the chemical admixtures is a characteristic feature of the high performance concrete.
The typical composition of the high strength concrete includes a cement content of 400 to 550 kg per cubic metre, a water-cement ratio of 0.25 to 0.35, silica fume of 5 to 15 percent of the cement, and a superplasticizer dosage of about 1 to 2 percent of the cement. The concrete is usually mixed with a pan mixer, compacted with a high frequency vibrator, and cured carefully, because the dense microstructure of the high strength concrete is sensitive to the curing conditions. The compressive strength of the high strength concrete at 28 days is 60 to 100 MPa or more.
Fibre reinforced concrete is the concrete containing short, discrete and randomly distributed fibres, which are added to the concrete to improve its toughness, its resistance to cracking and its ability to carry tensile stress after the cracking. The fibres may be made of steel, glass, synthetic materials such as polypropylene and nylon, or natural materials, and the commonly used steel fibre content is 0.5 to 1.5 percent by volume of the concrete. The fibres bridge the micro-cracks and prevent them from opening, so that the concrete shows a ductile behaviour instead of a brittle failure, and the fibre reinforced concrete is used for the pavements, the airport runways, the tunnel linings, the shotcrete, the precast products and the structures subjected to the impact and the fatigue.
Self compacting concrete is a highly flowable concrete that can spread and fill the formwork and the gaps between the reinforcement under its own weight, without the need for the vibration or the compaction. The self compacting concrete is made with a high powder content, a low water-cement ratio, a superplasticizer and a viscosity modifying agent, and it is characterised by the properties of the filling ability, the passing ability and the segregation resistance, which are measured by tests such as the slump flow test, the V-funnel test and the L-box test. The slump flow of the self compacting concrete is 650 to 800 mm, and it is used for the heavily reinforced sections, the congested elements, the repair works and the places where the vibration is difficult.
The self compacting concrete eliminates the noise and the labour of the vibration, improves the quality of the surface, and allows the concrete to be placed in the restricted and the deep sections where the compaction by vibration is impossible. The key requirements of the self compacting concrete are the stability of the mix, so that it does not segregate while flowing, and the deformability, so that it fills every corner of the formwork. The fresh properties of the self compacting concrete are controlled by the type and the dosage of the superplasticizer and the viscosity modifying agent.
Lightweight concrete is the concrete having a density lower than the normal concrete, which is achieved by using the lightweight aggregates such as the pumice, the expanded clay, the vermiculite and the foamed slag, or by introducing the air voids into the mix, or by omitting the fine aggregate as in the no-fines concrete. The density of the lightweight aggregate concrete is 300 to 1850 kg per cubic metre, compared with about 2400 kg per cubic metre for the normal concrete, and the compressive strength is correspondingly lower, usually 10 to 40 MPa. The lightweight concrete is used for the building partitions, the roof slabs, the insulating panels and the precast blocks, where the low self-weight and the good thermal insulation are more important than the high strength.
Ferrocement is a thin composite material made of a rich cement mortar reinforced with a layer or several layers of a fine wire mesh, and it has a high tensile strength, a high resistance to cracking and a large ductility, combined with a small thickness of 10 to 30 mm. The mortar used in the ferrocement has a cement-to-sand ratio of about 1:2 to 1:3 and a water-cement ratio of about 0.4 to 0.5, and the ferrocement is used for the boats, the water tanks, the silos, the shell roofs and the repair and the strengthening of the structures. The ferrocement can be cast into the curved and the thin shapes which are difficult to make with the conventional reinforced concrete.
The other special concretes include the polymer concrete, in which a polymer replaces the cement as the binder, giving a very high strength and an excellent resistance to the chemicals; the polymer modified concrete, in which the polymer is added to the ordinary cement concrete; the expansive concrete, which expands after setting to compensate for the shrinkage; the shotcrete, which is the concrete sprayed through a nozzle onto a surface at a high velocity, used for the tunnels and the slopes; the roller compacted concrete, which is a dry concrete compacted by the rollers, used for the pavements and the dams; and the vacuum concrete, in which the excess water is removed by the vacuum to increase the strength. Each special concrete has its own method of production and its own field of application, and the knowledge of these is tested in the examination.
| Type | Key constituent / feature | Typical strength | Main use |
|---|---|---|---|
| High strength concrete | Low w/c, silica fume, SP | Above 60 MPa | Tall building columns |
| Fibre reinforced concrete | Steel or synthetic fibres | 30-60 MPa | Pavements, shotcrete |
| Self compacting concrete | High powder, SP, VMA | 30-80 MPa | Heavily reinforced sections |
| Lightweight concrete | Lightweight aggregates | 10-40 MPa | Roofs, partitions, blocks |
| Ferrocement | Mortar + wire mesh | 30-60 MPa | Boats, tanks, shells |
| Polymer concrete | Polymer binder | 50-100 MPa | Chemical resistance |
| Property | Normal concrete | Self compacting concrete | Lightweight concrete |
|---|---|---|---|
| Density (kg/m3) | About 2400 | About 2400 | 300-1850 |
| Slump / slump flow | 25-150 mm slump | 650-800 mm slump flow | Depends on mix |
| Compaction required | Yes | No (self compacting) | Usually yes |
| Characteristic strength | 20-60 MPa | 30-80 MPa | 10-40 MPa |
| Typical application | General construction | Congested elements | Insulation and partitions |
flowchart TD
A[Special Concrete] --> B[High strength concrete]
A --> C[High performance concrete]
A --> D[Fibre reinforced concrete]
A --> E[Self compacting concrete]
A --> F[Lightweight concrete]
A --> G[Ferrocement]
A --> H[Polymer concrete]
A --> I[Shotcrete]
B --> B1[Above 60 MPa]
B --> B2[Silica fume and SP]
D --> D1[Steel and synthetic fibres]
D --> D2[Improves toughness]
E --> E1[No vibration needed]
E --> E2[Slump flow 650-800 mm]
F --> F1[Lightweight aggregates]
F --> F2[Density 300-1850 kg/m3]
G --> G1[Mortar + wire mesh]
G --> G2[Thin elements]
H --> H1[Polymer binder]
I --> I1[Sprayed at high velocity]
A --> J[Selection by application and cost]
The following diagrams show the principle of fibre reinforced concrete and the slump flow test for self compacting concrete.
The special concretes extend the range of the concrete technology beyond the ordinary concrete, and each of them is designed to meet a particular requirement of the modern construction industry. In this chapter we have studied the high strength and the high performance concretes, the fibre reinforced concrete, the self compacting concrete, the lightweight concrete, the ferrocement, and the other special concretes such as the polymer concrete, the shotcrete and the roller compacted concrete. The composition, the characteristic properties and the applications of each special concrete have been presented, together with the distinguishing features that help in the identification of the materials. The candidate must remember the numerical values associated with each special concrete, such as the strength of the high strength concrete above 60 MPa, the slump flow of the self compacting concrete of 650 to 800 mm, the density range of the lightweight concrete and the fibre content of the fibre reinforced concrete. With this knowledge of the special concretes, the candidate has completed the study of the whole chapter of concrete technology and is well prepared for the questions on all the ten topics of this subject in the examination.