Subject: Civil Engineering Chapter: Building Construction Topic: 7.2 Foundations
The foundation is the lowest part of a building that transmits the load of the superstructure to the soil in such a way that the soil is not overstressed and the building does not suffer excessive or unequal settlement. Every crack that appears in a wall, every jammed door and every sagging floor can usually be traced back to a poorly designed or poorly executed foundation. The foundation is therefore the most critical part of the structure, because while the walls and roof can be repaired, a failed foundation is difficult and extremely expensive to rectify. For competitive examinations such as SSC JE, RRB JE and state AE/JE papers, the types of foundations, their depth, their suitability for different soils and the causes of foundation failure form a highly productive topic for one-mark questions.
The foundation performs three essential functions. First, it spreads the concentrated load of the columns and walls over a sufficiently large area of soil so that the intensity of pressure on the soil stays below its safe bearing capacity. Second, it anchors the building against overturning and lateral forces such as wind and earthquake. Third, it provides a level and firm base on which the superstructure can be built. The part of the foundation that actually rests on the soil is called the footing or the base, while the part immediately below the plinth level is called the foundation bed. Together these elements ensure that the load path from the superstructure to the soil is continuous and safe.
In this chapter we will study the different types of foundations used in building construction, classified as shallow foundations and deep foundations. We will understand the conditions under which each type is chosen, the method of determining the depth of foundation including Rankine's formula for minimum depth, and the special types of foundations used for poor soils, machines and towers. We will also examine the common causes of foundation failure, because a site engineer must not only know how to build a foundation but also how to recognise the situations in which it may fail.
A shallow foundation is one in which the depth of the foundation is less than or equal to the width of the foundation. Such foundations are used when the soil at shallow depth has adequate bearing capacity and the load of the building is moderate. The depth of a shallow foundation is generally kept between 1.0 m and 1.5 m below ground level for ordinary buildings. Shallow foundations are divided into spread footings, strap footings, combined footings and mat or raft foundations.
The spread footing is the most common type. A spread footing spreads the column or wall load over a larger area of soil, and its width is chosen so that the pressure on the soil does not exceed the safe bearing capacity. Spread footings include wall or strip footings, which are continuous strips of concrete or masonry under load-bearing walls, isolated or pad footings, which are square or rectangular blocks under individual columns, and stepped footings, in which the projection of each step is limited to half the height of the step. The maximum projection of a spread footing beyond the wall face is limited so that the footing does not shear off from the wall.
A combined footing supports two or more columns on a single footing, and is used when two columns are so close together that their isolated footings would overlap, or when the property line prevents a column footing from extending on one side. A strap or cantilever footing connects two isolated footings by a beam called the strap, which transfers the unbalanced load. A raft or mat foundation is a continuous slab covering the entire area under the building, and it is used when the soil has a very low bearing capacity, when the column loads are very heavy, or when the individual footings would cover more than about half the plan area. The raft foundation distributes the load over the whole area and also reduces differential settlement.
A deep foundation is one in which the depth of the foundation is greater than the width, and the load is transferred to firm soil at considerable depth below the ground surface. Deep foundations are used when the top soil is weak, when heavy concentrated loads must be carried, or when the safe bearing stratum lies far below the surface. Pile foundations are the most common type of deep foundation, and piles are classified on the basis of the material and the method of driving.
On the basis of function, piles are classified as bearing piles, friction piles and combination piles. A bearing pile transfers its load through the weak soil to a firm stratum at the tip of the pile; it acts like a column. A friction pile transfers its load to the surrounding soil through the skin friction developed along its surface, and is used when the firm stratum is too deep to reach economically. A combination pile transfers the load partly by friction and partly by bearing. On the basis of material, piles may be timber, concrete, steel or composite, and on the basis of construction they are precast piles, which are cast at ground level and driven by a hammer, and cast-in-situ piles, which are formed by drilling a hole and filling it with concrete.
Under-reamed piles are widely used in India for buildings on expansive black cotton soil, because the enlarged bulb at the base anchors the pile against the uplifting force that develops when the soil swells. Well foundations or caissons are hollow cylindrical structures sunk into the ground for bridge piers, because they provide a large bearing area at great depth. Pneumatic caissons are used under water. A pier foundation is a cylindrical or rectangular concrete shaft drilled down to a firm stratum and filled with concrete, and it is used when the depth is moderate and the load is concentrated, as in bridge abutments.
The depth of a foundation must be sufficient to protect the foundation from the effects of weather, scour and shrinkage. Rankine's formula gives the minimum depth of foundation for a soil with a given safe bearing capacity, unit weight and angle of repose: the minimum depth equals the safe bearing capacity divided by the unit weight of soil multiplied by a factor involving the angle of repose, namely one minus sine of the angle divided by one plus sine of the angle. For an angle of repose of 30 degrees, this factor equals one third, and the minimum depth becomes the safe bearing capacity divided by three times the unit weight.
The depth of foundation for ordinary buildings is also governed by the general rule that the foundation should be taken at least 45 cm below the lowest level to which frost penetrates the ground, or below the depth of scour, whichever is lower. In addition, the width of the foundation is chosen so that the pressure on the soil is within the safe bearing capacity, and the foundation should be kept at a depth at which the soil is not disturbed by excavation for drains or by the shrinkage of the soil due to drying. Every foundation must be placed on soil that is firm and free from organic matter, and loose soil must be rammed and compacted before the foundation concrete is laid.
Foundations fail mainly due to shear failure of the soil, excessive settlement, unequal settlement between different parts of the building, lateral movement of the soil, or the action of the weather. Unequal or differential settlement is the most dangerous, because it causes cracks in walls, distortions in doors and windows and ultimately the collapse of the building. Foundation failure is also caused by the presence of trees and bushes whose roots absorb moisture and shrink the clay, by a high water table which softens the soil, and by the spread of the foundation being too small for the load. The remedies include enlarging the footing, deepening the foundation to firm soil, using a raft, and improving the soil by compaction, lime stabilisation or pile driving.
| Type of foundation | Category | Typical use |
|---|---|---|
| Strip / wall footing | Shallow | Load-bearing walls |
| Isolated / pad footing | Shallow | Individual columns |
| Combined footing | Shallow | Two close columns |
| Strap / cantilever footing | Shallow | Property line restraint |
| Raft / mat foundation | Shallow | Low bearing capacity soil |
| Pile foundation | Deep | Weak soil to deep stratum |
| Well / caisson | Deep | Bridge piers in water |
| Under-reamed pile | Deep | Black cotton soil |
| Feature | Shallow foundation | Deep foundation |
|---|---|---|
| Depth | Less than or equal to width | Greater than width |
| Load transfer | Through footing base | By bearing or skin friction |
| Soil condition | Firm soil near surface | Weak top soil |
| Cost | Lower | Higher |
| Settlement control | Moderate | Better control |
| Typical depth | 1.0 to 1.5 m | Several metres |
| Example | Spread, raft | Pile, well, pier |
flowchart TD
A[Foundations] --> B[Shallow foundations]
A --> C[Deep foundations]
A --> D[Depth of foundation]
A --> E[Foundation failure]
B --> B1[Spread footings]
B --> B2[Strap footing]
B --> B3[Combined footing]
B --> B4[Raft foundation]
C --> C1[Pile foundation]
C --> C2[Well / caisson]
C --> C3[Pier foundation]
C --> C4[Under-reamed pile]
D --> D1[Rankine's formula]
D --> D2[Below frost and scour]
E --> E1[Differential settlement]
E --> E2[Shear failure of soil]
B1 --> B1a[Wall strip, isolated, stepped]
C1 --> C1a[Bearing, friction, combination]
C1 --> C1b[Precast, cast-in-situ]
E1 --> E1a[Cracks in walls]
E1 --> E1b[Jammed doors and windows]
The following diagrams show the classification of foundations and the difference between a shallow spread footing and a deep pile foundation.
The foundation is the most vital part of a building, because it transmits every load of the superstructure to the soil and controls the settlement that decides the life of the structure. In this chapter we have studied shallow foundations, which include strip, isolated, combined, strap and raft footings, and deep foundations, which include bearing, friction and combination piles, under-reamed piles, wells and piers. We have understood that the choice between shallow and deep foundations depends on the depth of the firm stratum, the magnitude of the loads and the bearing capacity of the soil, and we have learned that the depth of foundation is governed by Rankine's formula, the frost line and the depth of scour. We have also examined the causes of foundation failure, chief among which is differential settlement, and the remedies such as enlarging the footing, using a raft or improving the soil. A candidate who can match the foundation to the soil condition and remember the values that govern its depth will secure the marks in this portion of the building construction section, because foundation questions are among the most frequently repeated in competitive examinations.