Subject: Civil Engineering Chapter: Building Construction Topic: 7.7 Staircases
A staircase is a series of steps arranged to provide access from one floor of a building to another. It is the most essential vertical circulation element of a multi-storey building, and in the event of a fire it is often the only means of escape. The design of a staircase therefore affects both the convenience of everyday movement and the safety of the occupants in an emergency. For competitive examinations such as SSC JE, RRB JE and state AE/JE papers, the terminology of staircases, the types of stairs, the rules for comfortable proportions of steps and the requirements of a good staircase are frequently tested, because the topic is compact, factual and directly applicable.
A step consists of two parts: the horizontal tread, on which the foot rests, and the vertical riser, which joins one tread to the next. The rounded projection of the tread beyond the riser is called the nosing. The series of steps is called a flight, and the landing is the platform provided between two flights at which the direction may change. The width of a stair is the distance between the outer faces of the stringers or walls enclosing it. The handrail is provided on the open side of the staircase for safety, the balusters are the small vertical posts supporting the handrail, and the inclined member which supports the steps on the open side is called the stringer or string. The total rise of a stair is the vertical distance between the floor levels, and the total run is the horizontal length of the stair.
In this chapter we will study the technical terms used in staircases, the requirements of a good staircase, the types of stairs such as straight, quarter-turn, half-turn, dog-legged, open-newel and spiral stairs, and the rules for determining the number of treads and risers. We will also learn the famous proportioning rules of stairs, such as the one which states that the sum of the tread and twice the riser should be about 60 to 64 cm, because comfortable and safe proportions are a favourite numerical question.
A good staircase must satisfy certain requirements. It should be so located that it is easily accessible from all parts of the building and gives convenient access to the main entrance, and it should be provided with adequate light and ventilation, preferably from a window or a skylight at each landing. The staircase should be designed for the maximum possible load that may come on it, keeping the steps of uniform size, and the pitch or slope should be neither too steep nor too flat, so that climbing is easy and safe. The treads should be provided with non-slippery surfaces and the stair should be provided with a strong handrail at the proper height of about 75 cm to 90 cm.
The proportions of the steps are the most important part of staircase design, and they are governed by the following rules. The sum of the riser and the tread should be between 40 cm and 45 cm for easy climbing. The product of the riser and the tread should be about 400 to 500 sq cm. The most widely used rule states that twice the riser plus the tread should be between 60 cm and 64 cm, which corresponds to the average comfortable stride of a person; for a riser of 15 cm, this gives a tread of about 30 cm, and for a riser of 16 cm, a tread of about 28 cm. The width of a staircase for a residential building should be about 0.9 m to 1.0 m, while for public buildings it should be 1.5 m to 1.8 m or more.
The number of treads in a flight is limited because a long unbroken flight is tiring and dangerous. A flight should not have more than about 10 to 12 steps, and a landing is provided after every such group of steps. The height of a single riser should not be less than 10 cm nor more than 20 cm, and the width of a tread should not be less than 25 cm. The landing should be of a width at least equal to the width of the stair, and the pitch of the staircase should be between 25 degrees and 40 degrees for comfort. These values give the examiner material for direct one-mark questions and for simple numerical problems.
Stairs are classified according to their shape and the arrangement of their flights. The straight stair has a single flight with no change of direction, and it is used where the space is long and narrow. The quarter-turn stair turns through a right angle at a landing, and it is used where the staircase is located in a corner. The half-turn stair turns through 180 degrees, so that the person climbs in one direction and then in the opposite direction; when the two flights are placed back to back with a landing between them, it is called a dog-legged stair, which is the most common type of stair in residential buildings because it occupies the least plan area.
The open-newel or open-well stair has a well or open space between the two flights, and it is used in public buildings such as schools, colleges and offices because it allows light and air to reach the middle and gives an imposing appearance. The circular stair winds in a complete circle and is used where the space is very limited, while the spiral stair is a compact form used for a single person's access, as to a tower or an attic. The bifurcated stair divides into two flights at the landing, which branch to left and right, and it is used in monumental buildings such as railway stations and cinemas. The doglegged, quarter-turn and half-turn stairs are the ones most commonly asked in examinations, and their plan shapes must be recognised from sketches.
Stairs may be made of stone, brick, timber, reinforced concrete or steel. Stone stairs are durable and used for external and monumental work, while timber stairs are used in upper floors of some residential buildings because they are light and warm. Reinforced concrete stairs are the most common in modern buildings because they are strong, fire resistant, economical and can be cast in any shape; they are cast along with the slab or on a supporting waist slab. Precast and pre-stressed concrete stairs are used for speed of construction. The choice of material depends on the importance of the building, the load, the fire resistance required and the cost.
The position of the staircase in the plan is decided in the earliest stage of planning, because it occupies a fixed area and its position governs the arrangement of rooms around it. The staircase is usually placed near the entrance and the kitchen, and in a corner of the building so that it does not interrupt the main rooms. The stairs should lead from the entrance to the upper floors with the least change of direction, and the number of steps in each flight should be odd or even as the situation demands, but the steps of a flight should always be of the same size so that the climb is rhythmical and safe. The stair should have a proper headroom, so that a tall person does not strike the head on the stair above; the minimum headroom is about 2.0 m to 2.1 m.
The fire safety of a staircase is of the greatest importance, because in a fire the staircase is the escape route. The staircase should be made of fire-resisting material such as reinforced concrete or steel encased in concrete, and it should be enclosed by fire-resisting walls and self-closing fire doors. A smoke-proof staircase with vents at the top should be provided in high buildings, and in very tall buildings one stair should be treated as a fire-escape stair. The handrails should be continuous, the treads non-slippery, and emergency lighting should be provided. The exit should open directly to a place of safety outside the building, and no combustible material should be stored under the staircase.
The structural design of an RCC stair considers the stair as a simply supported or cantilever slab. In a waist slab type of stair, the inclined slab carrying the steps spans between landings, and in a tread-riser or free-standing stair, each step is cantilevered from a central spine beam. The staircase is designed for its own weight, the weight of the steps and a live load of about 3 to 5 kN per square metre depending on the occupancy. The reinforcement is placed along the span, and distribution steel is provided across it. The dimensions of the staircase in the plan, with the number of steps, the risers and the treads, are fixed before the structural design begins.
| Term | Definition |
|---|---|
| Tread | Horizontal part of a step on which the foot rests |
| Riser | Vertical part of a step joining two treads |
| Nosing | Projection of the tread beyond the riser |
| Flight | Series of steps between landings |
| Landing | Platform between flights |
| Stringer | Inclined member supporting the steps |
| Baluster | Small vertical post supporting the handrail |
| Pitch | Angle of inclination of the stair |
| Rule | Expression | Comfortable range |
|---|---|---|
| Rise and tread sum | R + T | 40 to 45 cm |
| Twice rise plus tread | 2R + T | 60 to 64 cm |
| Rise and tread product | R x T | 400 to 500 sq cm |
| Height of riser | R | 10 to 20 cm |
| Width of tread | T | 25 cm minimum |
| Width of stair | - | 0.9 to 1.8 m |
flowchart TD
A[Staircases] --> B[Terms]
A --> C[Requirements]
A --> D[Proportions]
A --> E[Types of stairs]
A --> F[Fire safety]
B --> B1[Tread and riser]
B --> B2[Flight and landing]
B --> B3[Stringer and baluster]
C --> C1[Accessible location]
C --> C2[Light and ventilation]
C --> C3[Uniform steps]
D --> D1[2R + T = 60 to 64 cm]
D --> D2[R + T = 40 to 45 cm]
E --> E1[Straight stair]
E --> E2[Dog-legged stair]
E --> E3[Open-well stair]
E --> E4[Spiral and circular]
F --> F1[Fire-resisting materials]
F --> F2[Smoke-proof enclosure]
E2 --> E2a[Most common, least plan area]
E3 --> E3a[Public buildings]
The following diagrams show the parts of a staircase in section and the plan of a dog-legged stair.
The staircase is the essential vertical link of a building, combining everyday convenience with the vital function of escape in a fire, and its design requires the correct proportions, a sound structural system and careful detailing. In this chapter we have studied the terms of the staircase, including the tread, riser, nosing, flight, landing, stringer and baluster, and the requirements of a good stair such as accessible location, light and ventilation, uniform steps and non-slippery treads. We have learned the famous proportioning rules, above all 2R + T equal to 60 to 64 cm, and the limits of riser height, tread width and the number of steps in a flight. We have examined the common types of stairs, from the straight and quarter-turn to the dog-legged and open-well stairs, and the materials, with reinforced concrete being the dominant modern choice. Finally we have understood the fire safety of stairs, which makes them safe escape routes in an emergency. A candidate who can apply the proportioning rules and recognise the types of stairs will handle the staircase questions of the building construction paper with ease.