Subject: Civil Engineering Chapter: Environmental Engineering Topic: 15.2 Water Quality Parameters
Water taken from any natural source is never chemically pure, because it dissolves and carries impurities as it moves over the ground and through the soil. The impurities in water are broadly of three kinds: physical impurities such as turbidity, colour, taste and odour; chemical impurities such as dissolved salts, metals, hardness and gases; and biological impurities such as bacteria, viruses and algae. For an environmental engineer the study of water quality parameters is essential because every treatment process is designed to remove a particular class of impurity, and the standards of quality tell us whether the treated water is safe and wholesome for human consumption. In competitive examinations this topic is a rich source of direct questions, because the permissible limits of various parameters are fixed numerical values that can be tested very easily.
The quality of water is judged against standards laid down by the World Health Organisation and by national bodies such as the Bureau of Indian Standards. In India the relevant standard is IS 10500, which prescribes the desirable and permissible limits for physical, chemical and bacteriological parameters of drinking water. The significance of a quality parameter lies not only in its permissible value but also in the health and aesthetic problems caused when the value is exceeded. For example, an excess of fluoride causes fluorosis of the teeth and bones, an excess of nitrate causes blue baby disease, and the presence of coliform bacteria indicates faecal contamination of the water.
In this chapter we will study the physical, chemical and bacteriological parameters of water quality, learn the standard permissible limits under IS 10500, understand the meaning of terms such as turbidity, hardness, TDS, BOD and COD, and solve worked numerical examples on hardness and on dissolved oxygen. The emphasis throughout is on examination-oriented knowledge, so the standard values and the health effects of each impurity are presented in a form that can be memorised easily and applied directly to multiple-choice questions.
The physical parameters of water quality are those which can be judged by the senses, namely turbidity, colour, taste and odour, temperature and suspended solids. Turbidity is the cloudiness of water caused by suspended clay, silt, organic matter and microorganisms, and it is the most important physical parameter because it interferes with disinfection and makes the water aesthetically unacceptable. Turbidity is measured in nephelometric turbidity units, or NTU, using a nephelometer or turbidity meter, and the desirable limit for drinking water is 1 NTU with a permissible limit of 5 NTU under IS 10500. The turbidity of raw river water during floods may be as high as hundreds of NTU, which is why complete treatment is required.
Colour in water is caused by dissolved and suspended substances such as vegetable matter, iron, manganese and industrial wastes. The colour of water is measured by comparing it with standard platinum cobalt solutions and is expressed in Hazen units, and the desirable limit is 5 Hazen units with a permissible limit of 15 units. Taste and odour are caused by dissolved organic matter, algae, hydrogen sulphide and industrial wastes, and they are expressed by a threshold odour number which is the dilution ratio at which the odour just disappears. The temperature of drinking water should preferably be between 10 and 25 degrees Celsius, because warm water encourages the growth of bacteria and unpleasant tastes, and temperature also affects the dissolved oxygen content of water.
Suspended solids are the insoluble particles that remain in suspension and are measured by filtering a sample and weighing the residue. Total solids are the sum of suspended solids and dissolved solids, and total dissolved solids, or TDS, includes all the salts dissolved in the water. The desirable limit of TDS under IS 10500 is 500 mg/L and the permissible limit is 2000 mg/L. Water with TDS above 2000 mg/L is unpalatable and unsuitable for drinking, although it may still be used for industrial purposes. A worked numerical example will show the calculation of solids. If a water sample of 200 mL leaves a residue of 0.06 grams after evaporation and drying, the TDS in mg/L is 0.06 g / 200 mL = 0.06 x 1000 mg / 0.2 L = 300 mg/L. Solution: The total dissolved solids content of the sample is 300 mg/L, which is within the desirable limit of 500 mg/L.
The chemical parameters of water quality describe the dissolved chemical substances in water, and the most important of them are hardness, pH, chlorides, iron and manganese, fluorides, nitrates, alkalinity and dissolved oxygen. Hardness is the property of water that prevents the easy formation of lather with soap, and it is caused mainly by the bicarbonates, chlorides and sulphates of calcium and magnesium. Hardness is of two types: temporary hardness caused by bicarbonates which is removed by boiling, and permanent hardness caused by chlorides and sulphates which is not removed by boiling. The total hardness of a sample is usually expressed in terms of calcium carbonate equivalent, and the desirable limit in drinking water is 200 mg/L while the permissible limit is 600 mg/L.
The pH of water is a measure of its acidity or alkalinity, with a value of 7 being neutral, values below 7 being acidic and values above 7 being alkaline. The desirable range of pH for drinking water is 6.5 to 8.5, because very acidic water corrodes pipes and very alkaline water tastes bitter and forms scale. Chlorides in excess give a salty taste and indicate possible sewage contamination, with a permissible limit of 250 mg/L in the absence of other sources. Iron and manganese cause staining of clothes and a bitter metallic taste, and their limits are 0.3 mg/L and 0.1 mg/L respectively, while the permissible limit of fluoride is 1.5 mg/L and of nitrate is 45 mg/L, above which fluorosis and methaemoglobinaemia can occur.
Dissolved oxygen, or DO, is the amount of oxygen dissolved in water and is essential for aquatic life. Clean water can hold about 9 to 10 mg/L of oxygen at ordinary temperatures, and the DO decreases when organic pollution is present because the oxygen is consumed in decomposing the organic matter. The biochemical oxygen demand, or BOD, is the amount of oxygen required by microorganisms to decompose the organic matter in water, and it is measured by incubating the sample at 20 degrees Celsius for five days; this is called BOD5. The chemical oxygen demand, or COD, is the oxygen equivalent of the organic matter measured by chemical oxidation with potassium dichromate, and COD is always higher than BOD because chemical oxidation is more complete. A worked numerical example will illustrate the dilution method. A sample of sewage is diluted so that 5 mL of sewage is present in a 300 mL BOD bottle, the initial DO is 8 mg/L and the DO after five days is 3 mg/L. The BOD is then (8 - 3) x 300 / 5 = 5 x 60 = 300 mg/L. Solution: The five day BOD of the sewage sample is 300 mg/L, which is typical of a strong sewage.
The bacteriological quality of water is judged by tests for the presence of coliform bacteria, because the presence of coliforms indicates that the water may contain disease-producing organisms from sewage. The coliform group includes Escherichia coli and related organisms which are present in large numbers in the human intestine, and their presence in water proves that the water has been contaminated with faecal matter. The most probable number, or MPN, is the most common test, in which the water is incubated in tubes of lactose broth and the number of gas-producing tubes is used to find the MPN from statistical tables; the result is expressed as the MPN per 100 mL.
The WHO standard for a wholesome drinking water supply is an MPN of not more than 1 coliform organism per 100 mL for treated water, while an MPN of 1 to 3 is acceptable under some conditions and an MPN above 10 means the water must be rejected. In India the IS 10500 standard requires that coliforms should not be detectable in any 100 mL sample of drinking water. Other bacteriological tests include the membrane filter technique, in which the bacteria are trapped on a filter membrane and counted after incubation, and the presumptive and confirmed tests which check the ability of the bacteria to ferment lactose with the production of gas. The presence of E. coli in particular is taken as positive and final proof of faecal contamination.
The hygienic quality of a water supply is judged not only by the absence of coliforms but also by the absence of specific disease-causing organisms such as Vibrio cholerae, Salmonella typhi and the viruses of hepatitis. Because the direct examination for each pathogen is difficult, the coliform test is used as an indicator, on the assumption that if the indicator organisms are absent the pathogens are also absent. A worked numerical example will show the dilution of a sample for testing. A sewage sample has a BOD of 300 mg/L and the BOD bottle has a capacity of 300 mL; if the dilution water is expected to contain no oxygen demand, the depletion allowed is 5 mg/L. The dilution required so that the depletion is 5 mg/L is given by dilution factor = BOD / depletion = 300 / 5 = 60. Solution: The sewage must be diluted 60 times, meaning that 5 mL of the original sample should be placed in a 300 mL bottle, for the DO depletion to remain measurable.
| Parameter | Desirable Limit | Permissible Limit | Health Effect if Exceeded |
|---|---|---|---|
| Turbidity | 1 NTU | 5 NTU | Aesthetic, hinders disinfection |
| Colour | 5 Hazen units | 15 Hazen units | Aesthetic |
| pH | 6.5 to 8.5 | No relaxation | Corrosion or scale |
| Total dissolved solids | 500 mg/L | 2000 mg/L | Gastro-intestinal, taste |
| Total hardness | 200 mg/L | 600 mg/L | Scale, soap waste |
| Iron | 0.3 mg/L | 0.3 mg/L | Staining, metallic taste |
| Fluoride | 1.0 mg/L | 1.5 mg/L | Fluorosis above 1.5 mg/L |
| Nitrate | 45 mg/L | 45 mg/L | Blue baby disease |
| Chloride | 250 mg/L | 1000 mg/L | Salty taste, corrosion |
| MPN coliforms | Nil in 100 mL | Nil in 100 mL | Faecal contamination |
| Type | Parameter | Measuring Unit / Method | Standard Value |
|---|---|---|---|
| Physical | Turbidity | Nephelometer, NTU | 1 NTU desirable |
| Physical | Colour | Hazen units, Pt-Co scale | 5 units desirable |
| Physical | Taste and odour | Threshold odour number | 3 threshold number |
| Chemical | Hardness | EDTA titration, mg/L CaCO3 | 200 mg/L desirable |
| Chemical | Dissolved oxygen | Winkler method | 4 to 10 mg/L |
| Chemical | BOD | Incubation at 20 C for 5 days | 5 mg/L for clean water |
| Chemical | COD | Dichromate oxidation | Higher than BOD |
| Bacteriological | MPN coliforms | Lactose broth tubes | Not more than 1 per 100 mL |
flowchart TD
A[Water Quality Parameters] --> B[Physical]
A --> C[Chemical]
A --> D[Bacteriological]
B --> B1[Turbidity NTU]
B --> B2[Colour Hazen units]
B --> B3[Taste and odour]
B --> B4[Temperature]
B --> B5[Suspended solids, TDS]
C --> C1[Hardness]
C --> C2[pH]
C --> C3[Iron and manganese]
C --> C4[Fluoride, nitrate, chloride]
C --> C5[Dissolved oxygen, BOD, COD]
D --> D1[MPN coliform test]
D --> D2[Membrane filter test]
D --> D3[Presumptive and confirmed tests]
C1 --> E[Temporary by bicarbonates]
C1 --> F[Permanent by chlorides and sulphates]
C5 --> G[BOD5 at 20 C for 5 days]
C5 --> H[COD greater than BOD]
D1 --> I[E. coli indicates faecal contamination]
A --> J[Standard IS 10500]
J --> J1[Desirable limits]
J --> J2[Permissible limits]
The following diagrams help us visualise the classification of water quality parameters and the relation between the various chemical parameters.
Water quality parameters define what makes water safe and wholesome, and they form the yardstick by which every treatment plant is designed and every supply is judged. In this chapter we have studied the physical parameters of turbidity, colour, taste and odour and total solids, the chemical parameters of hardness, pH, chlorides, iron, fluoride, nitrate and dissolved oxygen, and the bacteriological parameters based on the coliform group. We have learned the standard desirable and permissible limits of IS 10500, understood the difference between BOD and COD, and solved numerical examples on total solids, BOD and dilution. The tables and the mind map provide a compact revision aid, while the common mistakes and exam tips highlight the exact points on which candidates lose marks. This knowledge is directly used in later chapters, because the choice of treatment processes in coagulation, sedimentation, filtration and disinfection depends entirely on the parameters of the raw water. By memorising the standard values and their health effects, a candidate can answer the quality-parameter questions with confidence and secure easy marks in the environmental engineering section of the examination.