Subject: Civil Engineering Chapter: Environmental Engineering Topic: 15.5 Water Treatment Processes
Water drawn from any natural source contains impurities that make it unsuitable for drinking, and the process by which these impurities are removed to make the water safe, pleasant and wholesome is called water treatment. The complete treatment of water involves a sequence of unit operations, each of which removes a particular class of impurity, and the sequence as a whole is called the treatment train or flow diagram of the treatment plant. For a civil engineering candidate, this chapter is the central topic of environmental engineering, because questions on the purpose, the position and the function of each treatment unit appear in every competitive examination, and the answers require a clear understanding of the whole treatment scheme.
The treatment of raw water depends upon the quality of the source. Ground water, which is usually clear and free from suspended matter, requires very little treatment and generally needs only disinfection, together perhaps with the removal of iron or hardness if they are present in excess. Surface water, on the other hand, contains turbidity, colour, bacteria and organic matter, and therefore requires the full sequence of treatment. The complete treatment train consists of screening, plain sedimentation, coagulation and flocculation, sedimentation after coagulation, filtration and disinfection, with auxiliary processes such as aeration and softening added as required.
In this chapter we will study the overall treatment sequence and the flow diagram of a conventional water treatment plant, the purpose and function of each unit operation, and the important considerations in the layout and operation of the plant, with a worked numerical example on the design of a sedimentation tank. The emphasis throughout is on examination-oriented knowledge, so the order of the units, the purpose of each unit and the standard design values are presented in a form that can be memorised easily and applied directly to multiple-choice questions.
The treatment of surface water begins with screening, which is the removal of large floating and suspended matter such as leaves, branches, rags and fish by means of screens or bars; screening is a preliminary treatment and does not change the chemical quality of the water. The water then passes to plain sedimentation, in which the water is held in a large tank at a low velocity so that the heavier suspended particles settle to the bottom under gravity. Plain sedimentation removes about 60 to 70 percent of the suspended matter and most of the settleable solids, but it does not remove the fine colloidal matter which remains suspended for a very long time.
The fine colloidal particles, which cause the turbidity that remains after plain sedimentation, are removed in the next stage by coagulation and flocculation. In coagulation, a chemical coagulant such as alum is rapidly mixed with the water so that it reacts with the colloids and neutralises their charges, and in flocculation, the water is slowly stirred so that the neutralised particles stick together and form larger flocs. The water then passes to the clarifier or sedimentation tank after coagulation, where the heavy flocs settle to the bottom. Coagulation, flocculation and sedimentation together remove the bulk of the turbidity and colour, and they also remove a large proportion of the bacteria because the bacteria are entangled in the flocs.
The water is then passed through the filters, in which the remaining fine suspended matter and a large part of the bacteria are removed by passing the water through a bed of sand or other granular material. Filtration removes about 98 to 99 percent of the bacteria present in the settled water, so it is the most important unit from the point of view of health. Finally, the filtered water is disinfected by adding chlorine, which destroys the disease-causing organisms that may still be present. The treated water is then stored in a clear water reservoir from which it is pumped into the distribution system. This complete sequence is represented by the mnemonic S - C - S - F - D, for screening, coagulation, sedimentation, filtration and disinfection.
In addition to the main treatment train, several auxiliary processes may be added according to the quality of the raw water. Aeration is the process of bringing the water into intimate contact with air, and it is used to remove tastes and odours, to add oxygen to the water, to remove carbon dioxide and hydrogen sulphide, and to oxidise iron and manganese. Aeration is done by waterfall aerators, in which the water falls in thin sheets through the air, by spray aerators, in which the water is sprayed into the air, and by diffused aerators, in which air is blown through the water. Aeration is especially important for ground water which contains dissolved iron and manganese, because the iron and manganese are oxidised to insoluble forms which can then be removed by sedimentation and filtration.
Softening is the removal of hardness from water, and it is done when the hardness of the water exceeds about 200 mg/L and causes excessive soap consumption and scale formation. The two main methods of softening are the lime-soda process, in which lime and soda ash are added to precipitate the calcium and magnesium salts, and the ion-exchange process, in which the water is passed through a bed of a zeolite or resin that exchanges its sodium ions for the calcium and magnesium ions of the water. The ion-exchange process is also used for the demineralisation of water for industrial purposes. Fluoridation is the addition of fluoride to water where the natural fluoride content is too low, because a small amount of fluoride prevents dental caries, while the removal of excess fluoride, called defluoridation, is done where the natural content exceeds 1.5 mg/L.
Other special treatments include the removal of iron and manganese by aeration followed by filtration, the removal of colour and taste by activated carbon, and the reduction of temporary hardness by boiling. In addition, modern plants may use advanced treatment processes such as activated carbon adsorption, reverse osmosis and membrane filtration where the water is badly polluted or where a very high quality of product water is required. For a competitive examination, however, the candidate is expected to know the purpose and position of the conventional units and the standard values of the design parameters, which are given in the tables below.
The layout of a treatment plant should follow a straight line so that the water flows through the units in the correct order under gravity as far as possible, which saves pumping. The units are so arranged that the treatment plant can be extended in future without disturbing the existing units. The whole plant is usually laid out with the intake at the highest point, followed by the coagulation and flocculation units, the settling tanks, the filters and finally the disinfection and clear water storage, so that the water flows by gravity through most of the plant.
The design of the individual units is based on standard parameters. The detention period of a plain sedimentation tank is 2 to 4 hours, of a coagulation tank with flocculator it is 2 to 4 hours, and of the flocculation chamber itself 10 to 40 minutes. The surface loading or overflow rate of a plain sedimentation tank is 12,000 to 18,000 litres per square metre per day, and of a clarifier after coagulation about 20,000 to 40,000 litres per square metre per day. The velocity of flow in sedimentation tanks is kept low so that the settling is not disturbed. A worked numerical example will illustrate the design of a sedimentation tank. If a town requires 10 million litres of water per day and the plain sedimentation tank is to have a detention period of 4 hours, the capacity of the tank is 10,000,000 x 4 / 24 = 1,666,667 litres. If the average depth is 3 metres, the surface area is 1,666,667 / 3 / 1000 = 555.6 square metres. The surface loading is 10,000,000 / 555.6 = 18,000 litres per square metre per day. Solution: A tank of about 555.6 square metres surface area and 3 metres depth satisfies both the detention period and the surface loading criterion for the stated demand.
A second numerical example shows the calculation for the coagulation tank. If the coagulated water is to be retained in the settling tank for 3 hours and the plant handles 12 million litres per day, the required capacity is 12,000,000 x 3 / 24 = 1,500,000 litres or 1500 cubic metres. With two tanks of equal size, each tank must hold 750 cubic metres, and with a depth of 3 metres each tank needs an area of 250 square metres. The surface loading is 12,000,000 / 500 = 24,000 litres per square metre per day, which is within the permissible range of 20,000 to 40,000 for a clarifier. Solution: Two clarifiers each of 250 square metres area and 3 metres depth satisfy the detention and loading requirements of the plant.
| Stage | Unit Process | Purpose | Main Removal |
|---|---|---|---|
| 1 | Screening | Remove large floating matter | Leaves, rags, fish |
| 2 | Plain sedimentation | Settle heavy suspended matter | 60 to 70 percent suspended solids |
| 3 | Coagulation and flocculation | Neutralise and agglomerate colloids | Colloidal turbidity, colour |
| 4 | Sedimentation after coagulation | Settle the flocs | Flocs, 90 percent bacteria |
| 5 | Filtration | Pass water through sand bed | 98 to 99 percent bacteria |
| 6 | Disinfection | Kill remaining organisms | Pathogenic bacteria |
| Unit | Detention Period | Surface Loading |
|---|---|---|
| Plain sedimentation tank | 2 to 4 hours | 12,000 to 18,000 L/m2/day |
| Coagulation tank | 2 to 4 hours | 20,000 to 40,000 L/m2/day |
| Flocculation chamber | 10 to 40 minutes | Low velocity stirring |
| Rapid gravity filter | 30 to 60 minutes | 5000 L/m2/hour |
| Slow sand filter | 4 to 8 hours | 100 to 300 L/m2/hour |
flowchart TD
A[Water Treatment Processes] --> B[Preliminary]
A --> C[Primary Treatment]
A --> D[Secondary Treatment]
A --> E[Final Treatment]
A --> F[Auxiliary Processes]
B --> B1[Screening]
C --> C1[Plain sedimentation]
C --> C2[Coagulation and flocculation]
C --> C3[Sedimentation after coagulation]
D --> D1[Filtration]
E --> E1[Disinfection]
F --> F1[Aeration]
F --> F2[Softening]
F --> F3[Fluoridation]
C2 --> G[Alum coagulant]
C2 --> H[Rapid mixing and slow stirring]
D1 --> I[Rapid gravity filter]
D1 --> J[Slow sand filter]
E1 --> K[Chlorination]
F1 --> L[Removes taste, odour, iron]
F2 --> M[Lime soda or ion exchange]
The following diagrams help us visualise the flow diagram of a treatment plant and the comparison of the filter types.
Water treatment is the process by which raw water is made safe and wholesome for human consumption, and it is the central practical activity of environmental engineering. In this chapter we have studied the complete treatment train of screening, coagulation, flocculation, sedimentation, filtration and disinfection, the purpose and function of each unit, and the auxiliary processes of aeration, softening and fluoridation. We have solved worked numerical examples on the sizing of a plain sedimentation tank and a coagulant clarifier, and we have summarised the standard design parameters in the quick revision tables. The flow diagram and the filter comparison diagrams make the layout of the plant easy to visualise. This knowledge is used directly in the next three chapters, which examine coagulation and flocculation, sedimentation and filtration, and disinfection in greater detail. By memorising the order of the units, the standard values and the removal percentages, a candidate can answer the treatment-plant questions with confidence and secure reliable marks in the environmental engineering section of the examination.