🏗️ Civil Engineering

15.7 Sedimentation and Filtration

Start MCQ Practice →

15.7 Sedimentation and Filtration

Subject: Civil Engineering Chapter: Environmental Engineering Topic: 15.7 Sedimentation and Filtration

1. Introduction

Sedimentation and filtration are the two solid-liquid separation processes that stand at the heart of a water treatment plant. Sedimentation is the process in which the suspended particles are allowed to settle to the bottom of a tank under the action of gravity, while filtration is the process in which the water is passed through a bed of granular material so that the remaining fine particles and microorganisms are removed. Together these two processes remove the great bulk of the turbidity and a very large proportion of the bacteria from the raw water, and they are therefore indispensable in the treatment of surface water. For a civil engineering candidate, sedimentation and filtration are among the most heavily examined topics, with questions on the design of tanks, the settling theory, the filter types and their rates of filtration.

Sedimentation makes use of the fact that particles denser than water will settle under gravity when the upward velocity of the water is lower than the settling velocity of the particles. The efficiency of a settling tank depends upon its surface area, because according to the ideal settling theory the removal of a particle depends only upon the surface area and the rate of flow, and not upon the depth of the tank. This remarkable result means that a shallow tank of large area is as effective as a deep tank of the same area, which guides the design of all settling tanks.

Filtration is the final polishing process that follows sedimentation. The water from the settling tank still contains fine suspended matter and about 90 percent of the bacteria present in the raw water, and the filter bed removes the remaining matter by straining, sedimentation, adsorption and biological action. Two main types of filters are used, the slow sand filter and the rapid gravity filter, and their characteristics, rates and methods of cleaning are frequently compared in examinations. In this chapter we will study the theory of settling, the design of sedimentation tanks, the types of filters and their design, with worked numerical examples.

2. Theory of Sedimentation

When a particle settles in still water, it accelerates until the resistance of the water balances the effective weight of the particle, after which it falls at a constant velocity called the settling velocity. For a spherical particle of diameter d and density of the particle material p, settling in water of density w, the terminal settling velocity is given by Stokes law, V = (g (p - w) d2) / (18 mu), where g is the acceleration due to gravity and mu is the dynamic viscosity of the water. Stokes law applies to particles smaller than about 0.1 millimetre, for which the flow around the particle is laminar. The settling velocity increases with the square of the particle diameter, which is why coagulation, which grows the flocs to a larger size, makes the settling so much more effective.

The ideal settling tank is assumed to have four properties: the flow is uniformly horizontal from inlet to outlet, the particles settle independently at their terminal velocity, the concentration of particles is uniform over the cross section at the inlet, and any particle reaching the bottom is removed. Under these assumptions, a particle is removed if its settling velocity is at least equal to the overflow rate or surface loading, which is defined as the rate of flow divided by the surface area of the tank. The overflow rate therefore has the dimensions of velocity, and the smallest particle that is fully removed is the one whose settling velocity equals the overflow rate.

This theory leads to the important conclusion that the efficiency of an ideal settling tank is independent of its depth and depends only upon the surface area and the rate of flow. A tank of given surface area removes the same fraction of particles whether it is shallow or deep, provided the flow conditions are ideal. In practice, however, a certain depth is necessary for sludge storage, for the inlet and outlet arrangements, and to avoid the scouring of the settled sludge by the horizontal velocity, and the practical depth of a settling tank is kept between 2.5 and 4 metres. A worked numerical example will illustrate the use of Stokes law. A particle of diameter 0.02 mm and density 2650 kg/m3 settles in water at 20 degrees Celsius, where the viscosity is 1.002 x 10^-3 N s/m2 and the density is 1000 kg/m3. The settling velocity is V = (9.81 x (2650 - 1000) x (0.02 x 10^-3)^2) / (18 x 1.002 x 10^-3) = (9.81 x 1650 x 4 x 10^-10) / (18.036 x 10^-3) = 6.4746 x 10^-6 / 0.018036 = 3.59 x 10^-4 m/s. Solution: The settling velocity of the particle is about 0.000359 m/s, or about 31 metres per day, which must be equalled or exceeded by the overflow rate for complete removal.

3. Design of Sedimentation Tanks

The design of a sedimentation tank is based on the detention period, the surface loading and the horizontal velocity. The detention period is the time for which the water is retained in the tank, and for a plain sedimentation tank it is taken as 2 to 4 hours, while for a clarifier after coagulation it is 2 to 4 hours as well, depending upon the water quality. The surface loading, or overflow rate, is the quantity of water treated per unit surface area per day, and for a plain sedimentation tank it is 12,000 to 18,000 litres per square metre per day, while for a coagulated water clarifier it is 20,000 to 40,000 litres per square metre per day. The horizontal velocity of flow is kept low, generally below 0.3 m/min for a plain tank, so that the settled particles are not scoured up again.

The length of the tank is usually taken as about four times the width, and the inlet and outlet arrangements are designed to distribute the flow uniformly. The inlet may be a weir or a perforated baffle, and the outlet is usually an overflow weir which maintains a constant water level. Sludge is removed from the bottom by scraper mechanisms in mechanical tanks or by cleaning the tank at intervals. In a continuous flow tank, the efficiency is somewhat less than that of the ideal tank because of short-circuiting, turbulence and the effect of the inlet and outlet zones, and a correction is applied in practice.

A worked numerical example will illustrate the design. A settling tank is to treat 5 million litres per day of coagulated water with a detention period of 3 hours and an overflow rate of 20,000 litres per square metre per day. The capacity of the tank is 5,000,000 x 3 / 24 = 625,000 litres = 625 cubic metres. The surface area required is 5,000,000 / 20,000 = 250 square metres. The depth of the tank is capacity divided by area = 625 / 250 = 2.5 metres. With a length to width ratio of 4, the width is sqrt(250 / 4) = sqrt(62.5) = 7.9 metres and the length is 31.6 metres. Solution: A tank of 250 square metres surface area, 31.6 metres by 7.9 metres, and 2.5 metres depth satisfies both the detention period and the overflow rate for the stated demand.

4. Filtration: Types and Design

Filtration is the process of passing the settled water through a bed of granular material, and two types of filters are in common use. The slow sand filter is the older type, in which the water is filtered at a very slow rate of 100 to 300 litres per square metre per hour through a bed of fine sand about 0.9 to 1.1 metres thick, supported on a gravel layer and an underdrainage system. The slow sand filter works partly by straining and partly by biological action, because a slimy layer of algae and bacteria, called the schmutzdecke, forms on the top of the sand and purifies the water biologically. The slow sand filter removes nearly all the bacteria and requires almost no coagulation, but it needs a large area and is cleaned by scraping off the top layer of sand.

The rapid gravity filter is the modern type, in which the water is filtered at the high rate of 3000 to 6000 litres per square metre per hour, with 5000 litres per square metre per hour as the usual design value, through a bed of coarser sand about 0.6 to 0.75 metres thick over a gravel support. The rapid filter works mainly by mechanical straining and requires the water to be coagulated and settled before filtration, otherwise it clogs quickly. The rapid filter occupies a small area but is costly, and it is cleaned by backwashing, in which water is forced upward through the bed to wash out the deposited impurities. A comparison of the two filters is a standard examination question.

The design of a rapid gravity filter is based on the filtration rate and the number of units. A worked numerical example will illustrate this. If a filter plant is to treat 10 million litres per day and the design rate is 5000 litres per square metre per hour, the total filter area required is 10,000,000 / 24 / 5000 = 83.3 square metres. If each filter bed has an area of 21 square metres and one bed is out of service for washing, the number of beds required is the total area divided by the bed area, plus one spare, giving about 4 beds plus 1 spare, or 5 beds in total. Solution: Five filter beds, each of about 21 square metres, are required to filter 10 million litres per day at the rate of 5000 litres per square metre per hour, allowing one bed to be washed at a time.

5. Quick Revision Tables

Table 1: Comparison of Slow Sand and Rapid Gravity Filters

Property Slow Sand Filter Rapid Gravity Filter
Filtration rate 100 to 300 L/m2/hour 3000 to 6000 L/m2/hour
Sand size Fine Coarser
Sand depth 0.9 to 1.1 m 0.6 to 0.75 m
Mechanism Straining and biological Mainly straining
Schmutzdecke Present, essential Absent
Pre-treatment Only plain settling Coagulation and settling
Cleaning Scraping surface sand Backwashing with water
Area required Large Small

Table 2: Design Values for Sedimentation and Filtration

Parameter Value
Detention period of plain tank 2 to 4 hours
Surface loading of plain tank 12,000 to 18,000 L/m2/day
Surface loading of clarifier 20,000 to 40,000 L/m2/day
Depth of settling tank 2.5 to 4 m
Ratio of length to width 3 to 5
Rapid filter design rate 5000 L/m2/hour
Slow filter design rate 100 to 300 L/m2/hour

6. Mind Map

flowchart TD
    A[Sedimentation and Filtration] --> B[Sedimentation Theory]
    A --> C[Settling Tank Design]
    A --> D[Filtration]
    B --> B1[Stokes law V = g(p-w)d2/18 mu]
    B --> B2[Overflow rate = flow / area]
    B --> B3[Efficiency depends on surface area]
    C --> C1[Detention period 2 to 4 hours]
    C --> C2[Surface loading 12,000 to 18,000]
    C --> C3[Depth 2.5 to 4 m]
    C --> C4[Length about 4 times width]
    D --> D1[Slow sand filter]
    D --> D2[Rapid gravity filter]
    D1 --> E[Rate 100 to 300 L/m2/hour]
    D1 --> F[Schmutzdecke biological layer]
    D1 --> G[Cleaned by scraping]
    D2 --> H[Rate 5000 L/m2/hour]
    D2 --> I[Needs coagulation]
    D2 --> J[Cleaned by backwashing]
    E --> K[Large area]
    H --> L[Small area]

7. Important Diagrams (SVG)

The following diagrams help us visualise the settling of particles in a tank and the section of a rapid gravity filter.

Ideal Settling Tank - Particle Trajectories INLET OUTLET Water surface Fast settling Slow settling SLUDGE ZONE (settled particles removed here) Overflow rate = Flow / Surface area, efficiency independent of depth Golden Rule Particle removal depends on surface area and flow, not on tank depth - use wide shallow tanks.

Section of a Rapid Gravity Filter WATER OVER FILTER BED From sedimentation tank SAND BED 0.6 to 0.75 m GRADED GRAVEL SUPPORT 0.3 to 0.45 m UNDERDRAINAGE SYSTEM (perforated pipe or nozzles) Filtered water out Backwash water in Rate 5000 L/m2/hour, cleaned by backwashing Golden Rule Rapid filters clean by backwashing upward; slow filters clean by scraping the top sand.

8. Common Mistakes

  1. Many students think the efficiency of a settling tank depends on its depth; according to ideal theory the removal depends on surface area and flow, not depth.
  2. A frequent error is to apply Stokes law with the diameter in millimetres; the diameter must be converted to metres before substitution.
  3. Some candidates mix up the filter rates and say the slow sand filter has the higher rate; the rapid gravity filter has the rate of about 5000 L/m2/hour while the slow sand filter has only 100 to 300.
  4. Students often forget that the rapid gravity filter requires the water to be coagulated and settled, while the slow sand filter works on simply settled water.
  5. A common mistake is to say that the slow sand filter is cleaned by backwashing; it is cleaned by scraping the top layer of sand.
  6. Many candidates use the same surface loading for plain settling and for coagulated water clarifiers; the clarifier after coagulation allows a higher loading of 20,000 to 40,000 L/m2/day.
  7. Students frequently forget to add a spare filter bed for washing; at least one bed is kept out of service for cleaning in a rapid gravity filter plant.

9. Exam Tips

  1. Memorise Stokes law V = (g (p - w) d2) / (18 mu) and remember that the settling velocity varies with the square of the diameter.
  2. Remember the standard overflow rate values: 12,000 to 18,000 L/m2/day for plain tanks and 20,000 to 40,000 L/m2/day for clarifiers.
  3. For the design of a tank, first find the capacity from the detention period, then the area from the overflow rate, and then the depth as capacity divided by area.
  4. Learn the filter comparison thoroughly: rate, sand size, cleaning method, pre-treatment and area, because a table of comparison is a favourite examination question.
  5. Remember that the rapid gravity filter design rate is 5000 L/m2/hour and that the total area equals the daily flow divided by 24 and by the rate.
  6. Note the schmutzdecke layer and its biological action in the slow sand filter, and remember that the filter works partly biologically.
  7. For a plant with several filters, divide the total area by the area of one bed and add one spare bed for the washing time.

10. Conclusion

Sedimentation and filtration are the workhorse processes of a water treatment plant, removing the great bulk of the suspended and colloidal matter and a very large proportion of the bacteria. We have studied the theory of settling through Stokes law and the concept of the overflow rate, learned that the efficiency of an ideal settling tank depends on its surface area and not on its depth, and designed a settling tank with the standard detention period and loading values. We have also studied the two main types of filters, the slow sand filter and the rapid gravity filter, compared their rates, mechanisms and methods of cleaning, and designed a rapid filter plant with a spare bed. The quick revision tables summarise the comparison and the design values, while the diagrams show the particle trajectories in the settling tank and the section of a rapid gravity filter. This knowledge connects directly with the previous chapter on coagulation, because the flocs formed there are settled and filtered here, and it leads into the next chapter on disinfection, which is the final safeguard of the treated water. By memorising the formulas, the standard values and the filter comparison, a candidate can answer the sedimentation and filtration questions with confidence and secure reliable marks in the environmental engineering section of the examination.