Subject: Civil Engineering Chapter: Environmental Engineering Topic: 15.8 Disinfection
Disinfection is the process by which the disease-producing organisms in water are destroyed, and it is the final and most important safeguard in a water supply scheme, because all the preceding treatment units remove suspended matter and bacteria only partially. Even after filtration, water may still contain pathogenic bacteria, viruses and cysts, and the safety of the public water supply depends entirely upon the efficiency of disinfection. For a civil engineering candidate, disinfection is a favourite topic of examinations because it involves the understanding of chlorine chemistry, the standard dosage values, the various forms of chlorine and the residual chlorine concept, all of which can be tested in one-mark questions as well as in numerical problems.
The ideal disinfectant must be able to destroy all pathogenic organisms, it must act quickly and effectively over the whole volume of water, it must be harmless to human beings at the concentration used, it must not impart any taste or odour to the water, it must be economical, and it must leave a residual concentration in the water so that the supply remains safe until it is consumed. Among the various disinfectants available, chlorine satisfies these requirements better than any other agent, and it is therefore used almost universally. Other methods of disinfection include ozone, ultraviolet radiation, chloramine, potassium permanganate and boiling.
In this chapter we will study the methods of disinfection, the chemistry of chlorination, the concept of residual chlorine and breakpoint chlorination, the chlorine demand and the dosage calculations, with worked numerical examples. The emphasis throughout is on examination-oriented knowledge, so the standard values, the reactions and the numerical procedure are presented in a form that can be memorised easily and applied directly to multiple-choice questions.
Chlorination is the most common method of disinfection, and chlorine is applied to the water either as chlorine gas or in the form of compounds such as bleaching powder, chloramine or chlorine dioxide. Chlorine is preferred because it is cheap, readily available, effective against a wide range of organisms, and it leaves a residual which protects the water during its passage through the distribution system. When chlorine gas is dissolved in water, it reacts to form hypochlorous acid and then hypochlorite ions, and it is the hypochlorous acid which is the effective disinfecting agent because it can penetrate the bacterial cell wall. Chlorine reacts with ammonia in the water to form chloramines, which are slower in action but give a longer-lasting residual.
Ozone is a powerful oxidising disinfectant which is very effective and leaves no taste or odour, but it is costly, it cannot be stored and it leaves no residual in the water, so a small dose of chlorine must still be added after ozonation. Ultraviolet radiation is used for small supplies and for water requiring no chemical residual; it kills the organisms quickly but has no lasting effect and the water must be clear for the rays to penetrate. Boiling is the oldest and surest method of disinfection and is used for household supplies, because boiling for 10 to 20 minutes kills all organisms. Chloramine, formed by adding ammonia with chlorine, is slower but gives a longer residual, and potassium permanganate and silver are used in special cases, while lime at high pH is sometimes used for large clear reservoirs.
Each method has its own advantages, and the choice depends upon the scale of the supply, the cost and the quality of the water. For a public supply, chlorination is the standard method, and it is the method on which the numerical questions are based. The efficiency of chlorination depends upon the concentration of chlorine, the time of contact, the temperature, the pH and the presence of interfering organic matter, and a longer contact time with a higher dose gives better disinfection.
The chlorine added to water is consumed in several ways before any disinfection can take place. A part of the chlorine reacts with the impurities such as organic matter, iron, manganese and ammonia, and is used up, and this quantity is called the chlorine demand of the water. Only the chlorine remaining after satisfying this demand is available for disinfection, and this remaining chlorine is called the residual chlorine. The total chlorine added is therefore the sum of the chlorine demand and the residual chlorine, and the residual chlorine is the quantity which actually kills the bacteria and which continues to protect the water in the distribution system. The residual chlorine in the water leaving a treatment plant should be about 0.2 mg/L after a contact period of 30 minutes, and a residual of 0.1 to 0.2 mg/L is maintained at the consumer's tap.
The relationship between the chlorine dose and the residual is not a straight line, and the phenomenon of breakpoint chlorination describes it. When chlorine is added to water containing ammonia, the residual first rises as the chlorine combines with the impurities, then falls again as the chloramines are oxidised and destroyed, and after a further point, called the breakpoint, the residual begins to rise again in proportion to the dose. The breakpoint is the point at which the chlorine demand of the water has been completely satisfied and any further chlorine appears as free residual chlorine. By dosing beyond the breakpoint, the engineer ensures that the water contains a stable free chlorine residual which cannot be destroyed by the impurities, and this is the standard practice for disinfection.
The removal of bacteria follows approximately Chick's law, which states that the number of organisms destroyed per unit time is proportional to the number present, so that the bacteria die logarithmically with time. The dose of chlorine is commonly expressed in mg/L, and the disinfection is designed for a contact time of about 30 minutes. A worked numerical example will illustrate the dosage calculation. If the chlorine demand of a water is 0.8 mg/L and the required residual is 0.2 mg/L, the dose to be added is 0.8 + 0.2 = 1.0 mg/L. For a treatment plant treating 20 million litres per day, the daily chlorine requirement is 20,000,000 x 1.0 / 10^6 = 20 kg per day. Solution: The plant requires a chlorine dose of 1.0 mg/L, or 20 kilograms of chlorine per day, to satisfy the demand and maintain the residual.
Chlorination is applied in different ways depending upon the stage of treatment and the quality of the raw water. Plain chlorination is the application of chlorine to raw water without any other treatment, and it is used only when the water is otherwise clean. Pre-chlorination is the application of chlorine before the other treatment units, and it helps to control algae and reduce the bacterial load on the filters, but it increases the chlorine demand because more organic matter is present. Post-chlorination is the application of chlorine after filtration, and it is the usual and most effective method, because the chlorine is used mainly for disinfection rather than for oxidation. Super-chlorination is the addition of chlorine in excess, from 5 to 15 mg/L, followed by dechlorination, and it is used for badly polluted water, while dechlorination is the removal of the excess chlorine with sulphur dioxide or activated carbon. Double chlorination applies chlorine both before and after filtration.
The choice of the chlorine compound affects the dosage. Chlorine gas contains about 99.9 percent available chlorine and is used for large plants, bleaching powder contains about 30 percent available chlorine and is used for small supplies, and chloramine and chlorine dioxide are used where a longer residual or special properties are required. A worked numerical example will show the calculation for bleaching powder. If a dose of 1.0 mg/L of available chlorine is required for a supply of 4000 litres of water, the chlorine required is 4000 x 1.0 / 10^6 = 0.004 kg = 4 grams. If bleaching powder contains 30 percent available chlorine, the quantity of bleaching powder required is 4 / 0.30 = 13.33 grams. Solution: About 13.3 grams of bleaching powder are required to disinfect 4000 litres of water at a dose of 1.0 mg/L of available chlorine.
A second numerical example involves the volume of a chlorine solution. If a tank of 10,000 cubic metres capacity of clear water is to be disinfected with a dose of 2 mg/L of chlorine, the chlorine required is 10,000 x 1000 x 2 / 10^6 = 20 kg. If the available chlorine solution contains 1 percent chlorine by weight, that is 10 grams per litre, the volume of solution required is 20,000 / 10 = 2000 litres. Solution: Two thousand litres of the 1 percent chlorine solution are needed to dose the tank at 2 mg/L, which demonstrates the difference between the mass of chlorine and the volume of the dilute solution.
| Method | Agent | Residual | Remarks |
|---|---|---|---|
| Chlorination | Chlorine gas or bleaching powder | Yes | Most common, cheap |
| Ozonation | Ozone | No residual | Very effective, costly |
| UV radiation | Ultraviolet rays | No residual | Small supplies only |
| Chloramine | Chlorine plus ammonia | Long lasting | Slow action |
| Boiling | Heat | No residual | Household supplies |
| Lime | High pH | No residual | Large clear reservoirs |
| Item | Value |
|---|---|
| Residual chlorine at plant outlet | 0.2 mg/L after 30 minutes |
| Residual at consumer tap | 0.1 to 0.2 mg/L |
| Contact time | About 30 minutes |
| Super-chlorination dose | 5 to 15 mg/L |
| Available chlorine in gas | 99.9 percent |
| Available chlorine in bleaching powder | 30 percent |
| Relation | Dose = demand + residual |
flowchart TD
A[Disinfection] --> B[Methods]
A --> C[Chlorination Chemistry]
A --> D[Chlorine Demand and Residual]
A --> E[Breakpoint Chlorination]
A --> F[Types of Chlorination]
B --> B1[Chlorination]
B --> B2[Ozonation]
B --> B3[UV radiation]
B --> B4[Boiling]
B --> B5[Chloramine]
C --> C1[Cl2 reacts with water]
C --> C2[Hypochlorous acid HOCl]
C --> C3[Effective disinfecting agent]
D --> D1[Chlorine demand]
D --> D2[Residual chlorine]
D --> D3[Dose = demand + residual]
E --> E1[Residual falls after initial rise]
E --> E2[Breakpoint where demand satisfied]
E --> E3[Free residual after breakpoint]
F --> F1[Plain chlorination]
F --> F2[Pre-chlorination]
F --> F3[Post-chlorination]
F --> F4[Super-chlorination and dechlorination]
The following diagrams help us visualise the breakpoint chlorination curve and the flow of chlorine through the treatment plant.
Disinfection is the final and decisive step in making water safe, because it destroys the disease-producing organisms that survive all the earlier treatment processes. We have studied the various methods of disinfection including chlorination, ozonation, ultraviolet radiation and boiling, the chemistry by which chlorine forms hypochlorous acid, and the concepts of chlorine demand, residual chlorine and breakpoint chlorination. We have learned that the dose is the sum of the demand and the residual, that the residual should be 0.2 mg/L after a contact time of 30 minutes, and that dosing beyond the breakpoint gives a stable free residual which protects the water through the distribution system. The worked numerical examples have shown how to calculate the daily chlorine requirement and the quantity of bleaching powder and chlorine solution needed. The quick revision tables and the diagrams summarise the methods, the values and the breakpoint curve for rapid revision. This knowledge completes the treatment train, and the next chapter considers how the treated water is carried to the consumers through the distribution system. By memorising the residual values, the dose relation and the chlorine chemistry, a candidate can answer the disinfection questions with confidence and secure reliable marks in the environmental engineering section of the examination.