🏗️ Civil Engineering

11.9 Laminar and Turbulent Flow

Start MCQ Practice →

11.9 Laminar and Turbulent Flow

Subject: Civil Engineering Chapter: Fluid Mechanics Topic: 11.9 Laminar and Turbulent Flow

1. Introduction

The flow of a real fluid is governed by the balance between the inertia forces that keep the fluid moving and the viscous forces that resist the motion, and the character of the flow depends entirely on which of these forces dominates. When the viscous forces dominate, the fluid particles move in smooth parallel layers without any intermixing, and the flow is called laminar flow; when the inertia forces dominate, the particles move in an irregular, fluctuating and intermixing manner, and the flow is called turbulent flow. This distinction was first established experimentally by Osborne Reynolds in 1883, who demonstrated with a simple dye-injection experiment that the flow in a pipe is laminar at low velocities, becomes unstable in a transitional range, and turns turbulent at high velocities. The dimensionless number that bears Reynolds' name, the Reynolds number, is the single most important criterion for distinguishing the two regimes of flow.

The laminar and turbulent regimes differ in almost every respect that matters to an engineer. The velocity profile across a pipe is parabolic in laminar flow, with the mean velocity equal to half the maximum velocity, while it is flatter and fuller in turbulent flow, with the mean velocity equal to about 0.8 times the maximum velocity. The friction factor of the pipe depends on the Reynolds number and the roughness of the wall, with laminar friction following the simple relation f = 64/Re and turbulent friction following the Colebrook or Moody equations. The head loss due to friction, given by the Darcy-Weisbach equation, is proportional to the first power of velocity in laminar flow but to a higher power in turbulent flow, so pumping costs rise sharply once the flow becomes turbulent.

In this chapter we will study the Reynolds experiment and the critical Reynolds number, the characteristics of laminar and turbulent flow, and the analytical treatment of laminar flow through a circular pipe, including the velocity distribution, the Hagen-Poiseuille equation and the relation between mean and maximum velocities. We will also study the Darcy-Weisbach equation for the loss of head due to friction in pipes, the friction factor and the Moody chart, and the energy losses in pipes including major and minor losses. Every formula is illustrated with a worked numerical example, because numerical problems on Reynolds number, Hagen-Poiseuille flow, friction loss and pipe discharge are among the most common questions in the hydraulics section of civil engineering examinations.

2. Reynolds Experiment and Critical Velocity

The character of the flow in a pipe was demonstrated by Osborne Reynolds using a long glass tube fed from a tank of water, with a fine stream of dye introduced at the entrance. When the velocity was low, the dye remained as a thin straight filament running the whole length of the tube, showing that the particles moved in parallel straight lines without intermixing, which is laminar flow. As the velocity was gradually increased, a critical value was reached at which the dye filament became wavy and then broke up into eddies, and at still higher velocities the dye mixed completely with the water, showing that the flow had become turbulent. This experiment established that the flow in a pipe is laminar at low velocities, transitional at intermediate velocities and turbulent at high velocities.

The flow regime is decided by the Reynolds number, defined as Re = (rho V D)/mu = (V D)/nu, where V is the mean velocity, D is the pipe diameter, rho is the density, mu is the dynamic viscosity and nu is the kinematic viscosity. For flow in a pipe, the flow is laminar when Re is less than 2000, transitional between 2000 and 4000, and turbulent when Re is greater than 4000. The lower critical Reynolds number, below which the flow is always laminar, is about 2000, and the upper critical value, above which the flow is always turbulent, is about 4000; between these values the flow is unstable and depends on disturbances and pipe roughness. For a pipe, the critical velocity at which the flow changes from laminar to turbulent is V(c) = (Re(c) mu)/(rho D) = (Re(c) nu)/D.

Worked Example 1: Water at 20 degree Celsius flows through a pipe of diameter 100 mm at a mean velocity of 1 m/s. Determine the Reynolds number and the type of flow. Take the kinematic viscosity of water as 1 x 10^-6 m2/s. Solution: Re = V D/nu = 1 x 0.1/(1 x 10^-6) = 1 x 10 to the power 5. Since the Reynolds number is far greater than 4000, the flow is turbulent. The critical velocity for this pipe would be V(c) = 2000 x 1 x 10^-6/0.1 = 0.02 m/s, so any velocity above 0.02 m/s produces turbulent flow in a 100 mm pipe carrying water.

3. Laminar Flow Through a Circular Pipe

Laminar flow in a circular pipe was analysed analytically by Poiseuille and Hagen, who derived the equation for the discharge and the velocity distribution. In fully developed laminar flow through a horizontal pipe of diameter D and length L, the velocity distribution across the section is parabolic, with the velocity zero at the wall and a maximum at the centre of the pipe. The maximum velocity at the centre is V(max) = (gamma h(f) D squared)/(32 mu L), where h(f) is the loss of head over the length L, and the velocity at any radius r from the centre is V(r) = V(max) (1 - (2r/D) squared). The mean velocity is exactly half the maximum velocity, V = V(max)/2, which is a standard result for laminar flow in a pipe.

The discharge through the pipe in laminar flow is given by the Hagen-Poiseuille equation Q = (pi gamma h(f) D to the power 4)/(128 mu L) = (pi P h(f) D to the power 4)/(128 mu L), where P is the specific weight gamma. The equation shows that the discharge is proportional to the fourth power of the diameter, so doubling the diameter increases the discharge sixteen times, which is why the equation is so sensitive to the pipe size. The loss of head due to friction in laminar flow is obtained by rearranging the equation as h(f) = (32 mu V L)/(gamma D squared), which shows that the head loss in laminar flow is proportional to the first power of the velocity, a result that distinguishes laminar from turbulent flow.

Worked Example 2: Oil of dynamic viscosity 0.1 N s/m2 and specific gravity 0.9 flows through a pipe of 50 mm diameter and 40 m length. The pressure difference between the two ends of the pipe is 20 kPa. Determine the discharge through the pipe assuming laminar flow. Solution: Specific weight of oil gamma = 0.9 x 9810 = 8829 N/m3. Loss of head h(f) = p/gamma = 20000/8829 = 2.265 m. By the Hagen-Poiseuille equation Q = (pi gamma h(f) D to the power 4)/(128 mu L) = (3.1416 x 8829 x 2.265 x 0.05 to the power 4)/(128 x 0.1 x 40) = (3.1416 x 8829 x 2.265 x 0.00000625)/(512) = 0.3929/512 = 0.000767 m3/s = 0.767 litres per second. Mean velocity V = Q/A = 0.000767/(3.1416 x 0.05 x 0.05/4) = 0.000767/0.001963 = 0.391 m/s. Reynolds number Re = rho V D/mu = 900 x 0.391 x 0.05/0.1 = 176, which is below 2000, confirming that the flow is laminar and the assumption is valid.

4. Turbulent Flow, Darcy-Weisbach Equation and Friction Factor

In turbulent flow the particles move in a disorderly manner with eddies and random fluctuations superimposed on the mean motion, and the velocity profile is flatter than the parabola of laminar flow, with the velocity nearly uniform over the central portion of the pipe and a steep drop in a thin boundary layer near the wall. The mean velocity in turbulent flow is approximately 0.8 times the maximum velocity, compared with 0.5 for laminar flow. Turbulent flow cannot be analysed exactly like laminar flow because of the random fluctuations, and it is described by empirical relations based on experiment, the most important of which is the Darcy-Weisbach equation for the loss of head due to friction in a pipe: h(f) = (f L V squared)/(2 g D), where f is the dimensionless friction factor, L is the length, V is the mean velocity, D is the diameter and g is the acceleration due to gravity.

The friction factor f depends on the Reynolds number and the relative roughness of the pipe wall. For laminar flow the friction factor is simply f = 64/Re, which can be obtained by rearranging the Hagen-Poiseuille equation. For turbulent flow in a smooth pipe the friction factor follows the Blasius equation f = 0.316/Re to the power 0.25, valid for Reynolds numbers up to about 10 to the power 5, and for rough pipes the friction factor is given by the Colebrook equation and presented graphically in the Moody chart. The friction factor in turbulent flow decreases slowly with increasing Reynolds number and increases with increasing relative roughness. The total loss of head in a pipe system is the sum of the major losses due to friction along the length and the minor losses due to fittings such as bends, elbows, valves, sudden enlargements and contractions, which are expressed as h(m) = K V squared/(2g), where K is the loss coefficient.

Worked Example 3: Water flows through a pipe of 200 mm diameter and 500 m length at a mean velocity of 2 m/s. Determine the loss of head due to friction if the friction factor is 0.02. Solution: By the Darcy-Weisbach equation h(f) = (f L V squared)/(2 g D) = (0.02 x 500 x 4)/(2 x 9.81 x 0.2) = 40/(3.924) = 10.19 m. Hence the frictional loss of head is 10.19 m over the 500 m length of pipe, which corresponds to a pressure loss of 10.19 x 9810 = 100 kPa. This is the head that a pump must provide to overcome friction in this pipeline.

5. Quick Revision Tables

Table 1: Comparison of Laminar and Turbulent Flow

Property Laminar flow Turbulent flow
Reynolds number Below 2000 Above 4000
Particle motion Parallel layers, no mixing Random, fluctuating, intermixing
Velocity profile Parabolic Flat and full
Mean to maximum velocity V = 0.5 V(max) V = 0.8 V(max)
Friction factor f = 64/Re Moody chart, Blasius equation
Head loss varies as First power of velocity Higher power of velocity

Table 2: Formulas for Flow in Pipes

Quantity Formula Remarks
Reynolds number Re = rho V D/mu = V D/nu Dimensionless
Hagen-Poiseuille discharge Q = pi gamma h(f) D4/(128 mu L) Laminar flow only
Maximum velocity laminar V(max) = gamma h(f) D2/(32 mu L) At pipe centre
Mean velocity laminar V = V(max)/2 Standard result
Darcy-Weisbach head loss h(f) = f L V2/(2 g D) All pipe flow
Blasius friction factor f = 0.316/Re0.25 Smooth pipe, Re below 10 to power 5

6. Mind Map

flowchart TD
    A[Laminar and Turbulent Flow] --> B[Reynolds number]
    A --> C[Laminar flow]
    A --> D[Turbulent flow]
    A --> E[Head loss in pipes]
    B --> B1[Re below 2000 laminar]
    B --> B2[Re above 4000 turbulent]
    B --> B3[Re = V D / nu]
    C --> C1[Hagen-Poiseuille equation]
    C --> C2[Parabolic velocity profile]
    C --> C3[V = 0.5 V max]
    D --> D1[Eddies and mixing]
    D --> D2[Flat velocity profile]
    D --> D3[V = 0.8 V max]
    E --> E1[Darcy-Weisbach equation]
    E --> E2[Major losses due to friction]
    E --> E3[Minor losses due to fittings]
    C1 --> F[Q = pi gamma h(f) D4/(128 mu L)]
    E1 --> G[h(f) = f L V2/(2 g D)]
    B1 --> H[f = 64/Re]

7. Important Diagrams (SVG)

The following diagrams show the parabolic velocity profile of laminar flow compared with the flatter turbulent profile in a pipe, and the Moody-type variation of the friction factor with the Reynolds number.

Velocity Profiles: Laminar and Turbulent Flow Laminar parabola V mean = 0.5 V max Flat turbulent profile V mean = 0.8 V max Velocity zero at the wall, maximum at the centre Golden Rule Laminar profile is parabolic with Vmean equal to half Vmax; turbulent is flatter.

Friction Factor Variation with Reynolds Number Friction factor f Reynolds number Re (log scale) Re = 2000 f = 64/Re for laminar flow Turbulent, depends on roughness Transition zone Golden Rule Friction factor falls with Reynolds number in laminar flow and rises with roughness in turbulent flow.

8. Common Mistakes

  1. Many students think the mean velocity in turbulent flow is half the maximum velocity; that ratio belongs to laminar flow, while turbulent flow has a mean of about 0.8 times the maximum.
  2. A frequent error is to use the Hagen-Poiseuille equation for turbulent flow, which is valid only for laminar flow and would give a completely wrong discharge.
  3. Some candidates use the kinematic viscosity in place of the dynamic viscosity in the Hagen-Poiseuille equation, which is dimensionally inconsistent.
  4. Students often forget to take the diameter in metres, and the fourth power of the diameter in the Hagen-Poiseuille equation makes the result extremely sensitive to the units.
  5. A common mistake is to apply f = 64/Re in turbulent flow; this relation is valid only for laminar flow, and the Blasius or Moody relations must be used in turbulent flow.
  6. Many candidates ignore the minor losses due to valves and fittings in a pipeline and compute only the major friction loss, underestimating the total head loss.
  7. Some students state that the critical Reynolds number for pipe flow is 5000 or 10 to the power 5; the standard values are about 2000 and 4000 for the lower and upper critical values.
  8. Another recurring error is to take the mean velocity as V(max) in discharge calculations; the discharge must use the mean velocity, which is half V(max) in laminar flow.

9. Exam Tips

  1. Memorise the critical Reynolds numbers: 2000 for the lower limit of laminar flow and 4000 for the onset of fully turbulent flow in pipes.
  2. Remember the standard ratios V = 0.5 V(max) for laminar flow and V = 0.8 V(max) for turbulent flow in a pipe.
  3. For laminar pipe flow, use the Hagen-Poiseuille equation Q = pi gamma h(f) D4/(128 mu L) and remember that the discharge varies as the fourth power of the diameter.
  4. For friction loss in any pipe, use the Darcy-Weisbach equation h(f) = f L V2/(2 g D) and the laminar friction factor f = 64/Re.
  5. Remember the Blasius equation f = 0.316/Re to the power 0.25 for smooth pipes at Reynolds numbers up to 10 to the power 5.
  6. Note that the head loss in laminar flow is proportional to the first power of velocity, while in turbulent flow it is proportional to roughly the second power.
  7. Always add the minor losses h(m) = K V2/(2g) to the major losses when a pipeline has valves, bends and fittings.
  8. Practise one numerical each on Reynolds number, Hagen-Poiseuille discharge and Darcy-Weisbach head loss, since these three cover the standard examination problems.

10. Conclusion

The distinction between laminar and turbulent flow is fundamental to the analysis and design of every pipe system in civil engineering. In this chapter we have studied the Reynolds experiment, which first demonstrated the transition between the two regimes, and the Reynolds number criterion, with laminar flow below 2000, transitional flow between 2000 and 4000, and turbulent flow above 4000. We have examined the analytical treatment of laminar flow through a circular pipe, including the parabolic velocity distribution, the relation between mean and maximum velocities, and the Hagen-Poiseuille equation for the discharge. The empirical treatment of turbulent flow through the Darcy-Weisbach equation, the friction factor and the Moody chart was explained, together with the major and minor losses in a pipe system. The worked examples on the Reynolds number, the Hagen-Poiseuille discharge and the Darcy-Weisbach head loss demonstrated the standard numerical procedures. An understanding of these two regimes and their governing formulas is essential, because the choice between laminar and turbulent analysis decides the accuracy of every calculation of head loss, discharge and pumping power in water supply and irrigation engineering.