🏗️ Civil Engineering

Types of Foundations

Start MCQ Practice →

Types of Foundations

Subject: Civil Engineering Chapter: Foundation Engineering Topic: 19.1 Types of Foundations

1. Introduction

The foundation is the lowermost part of a structure that transmits its load, along with the self-weight of the structure, safely to the soil or rock below. A foundation is essential because soil, being a comparatively weak material in tension, must not be overloaded beyond its safe bearing capacity. If the load transmitted by the foundation exceeds the resistance offered by the soil, the structure settles, tilts or fails catastrophically. For a competitive examination candidate, foundation engineering is one of the most productive topics because questions on the classification of foundations, the choice between shallow and deep foundations, and the suitability of each type for a given site appear very frequently in civil engineering papers such as RRB JE, SSC JE, GATE and State AE/JE examinations.

Every structure, whether a small residential building, a railway bridge or a multi-storey tower, rests on soil whose properties vary widely from place to place. The soil at a site may be a strong rock, a stiff clay, a loose sand or a soft marine clay, and each type of ground demands a different kind of foundation. The engineer must therefore study the soil report, the magnitude of loads, the depth of the water table and the permissible settlement before selecting a foundation. The whole art of foundation engineering is essentially the process of matching the foundation system to the load and the soil so that the structure remains safe, serviceable and economical for its entire design life.

Foundations are broadly classified into two major groups: shallow foundations, in which the depth of the footing is generally equal to or less than its width and the load is transferred to the soil near the ground surface, and deep foundations, in which the depth is much greater than the width and the load is carried to deeper, stronger soil strata. Within these two broad groups there are many individual types such as spread footings, combined footings, raft or mat foundations, pile foundations, pier foundations and well or caisson foundations. This chapter explains the principle of classification, the characteristic features of each type, the factors that govern the choice of a foundation and the criteria used by engineers to decide whether a shallow or a deep foundation is required at a given site.

2. Classification of Foundations

Foundations are classified primarily on the basis of the ratio of the depth of the foundation to the width of the foundation, and on the mode in which the load is transferred to the soil. When the depth of the foundation D is less than or equal to the width B, that is D/B less than or equal to 1, the foundation is called a shallow foundation. When D/B is greater than 1, and especially when the load is transferred to deeper strata through piles or wells, the foundation is called a deep foundation. In practice, shallow foundations are used where the soil at shallow depth has adequate bearing capacity, while deep foundations are used where the near-surface soil is weak, where heavy column loads are involved, or where scour and undermining are a danger.

Shallow foundations transfer the load to the soil purely through the base of the footing, so the load path is short and direct. Deep foundations, on the other hand, transfer the load partly through the base and partly through friction along the sides of the piles or the wells, and they extend the load to a stratum that can safely support it. The classification therefore has a direct bearing on the method of analysis: shallow foundations are analysed using the theory of bearing capacity of a footing near the surface, whereas deep foundations are analysed considering the combined resistance offered by the base and the shaft of the pile or well.

Worked Example 1

A rectangular footing of width 2 m is provided at a depth of 1.5 m below ground level. Determine whether it is a shallow or a deep foundation.

Solution:

The ratio of depth to width is D/B = 1.5/2 = 0.75.

Since D/B = 0.75 is less than 1, the foundation is classified as a shallow foundation. The load is transferred to the soil near the ground surface through the base of the footing.

Worked Example 2

A pier foundation of diameter 0.8 m is taken down to a depth of 4.5 m. Classify the foundation.

Solution:

Taking the width equal to the diameter, B = 0.8 m. The ratio D/B = 4.5/0.8 = 5.625.

Since D/B is much greater than 1, the foundation is classified as a deep foundation, because the load is transferred to a deeper soil stratum through the pier.

3. Types of Shallow Foundations

The shallow foundations commonly used in practice are the spread footing, the strip footing, the combined footing, the strap footing and the raft or mat foundation. An isolated or spread footing supports a single column and is the simplest and most economical form of foundation; it is square, rectangular or circular in plan, and its size is governed by the safe bearing capacity of the soil. A strip footing is a continuous footing provided under a wall or a row of closely spaced columns, distributing the wall load along its length. A combined footing is used when two columns are close together so that isolated footings would overlap, when one column is very near the property line, or when the loads of the two columns are disproportionate. A strap footing connects two isolated footings by a rigid beam called a strap so that the eccentricity of the load is reduced. A raft or mat foundation is a single large slab covering the entire area under the structure and is used when the soil is weak and the column loads are so heavy that individual footings would cover more than half of the total plan area.

The spread footing and its variants are the most widely used shallow foundations because they are easy to construct, economical and suitable for firm soils. When a shallow foundation is placed, the soil immediately beneath the base is stressed, and the footing is designed so that the maximum bearing pressure does not exceed the safe bearing capacity of the soil and the settlement remains within permissible limits. The depth of a shallow foundation is decided from the consideration of the depth of the topsoil, the presence of expansive soil, the depth of frost penetration and the position of the water table, and as a rule the footing must be placed at least 50 cm below the ground surface to protect it from the effects of weathering.

Worked Example 3

A square column footing carries a total load of 600 kN. If the safe bearing capacity of the soil is 150 kN/m2, find the size of the footing.

Solution:

Required base area A = load / safe bearing capacity = 600 / 150 = 4 m2.

For a square footing, side = square root of 4 = 2 m.

Therefore a square footing of side 2 m is provided.

4. Types of Deep Foundations

Deep foundations are used when the soil at shallow depth is weak or when heavy loads, lateral forces or scour conditions make shallow foundations unsuitable. The principal types are pile foundations, pier foundations, and well or caisson foundations. A pile is a slender column of timber, concrete or steel that is driven, bored or screwed into the ground, and it transmits the load either by end bearing on a hard stratum at the tip or by skin friction along its shaft, or by a combination of both. Piles are used under heavily loaded columns, under bridge abutments, in soft clay, loose sand and expansive soil, and in marine construction. A pier is a large-diameter column constructed by drilling a hole and filling it with concrete, and it is usually a load-carrying member for very heavy loads. A well foundation is a hollow cylindrical or rectangular box that is sunk into the ground, and it is used extensively for bridge piers in river beds where the depth of scour is large.

The choice between a pile and a well foundation is governed by economy, the availability of machinery, the nature of the soil and the magnitude of the loads. Pile foundations are preferred in cohesive soils and for lighter to moderate loads, whereas well foundations are preferred for heavy bridge piers because a well can be sunk to great depths and develops enormous end bearing and skin friction. Deep foundations require careful estimation of the load capacity, because the soil cannot be inspected after construction and any mistake is very expensive to rectify. The capacity of a deep foundation is evaluated by static formulas based on soil parameters, by dynamic formulas based on driving resistance, or by load tests conducted on a trial pile.

Worked Example 4

A pile foundation is driven to a depth of 18 m in a firm stratum. If the permissible load on the pile is 500 kN and 12 such piles are provided, find the total load-carrying capacity of the pile group, assuming 100 percent group efficiency.

Solution:

Total capacity = number of piles x load per pile = 12 x 500 = 6000 kN.

Therefore the pile group can safely carry 6000 kN.

5. Quick Revision Tables

Table 1: Comparison of Shallow and Deep Foundations

Basis Shallow Foundation Deep Foundation
Depth to width ratio D/B equal to or less than 1 D/B greater than 1
Depth below ground Small (up to about 3 m) Large (extend to deep strata)
Load transfer Through the base only Base and side friction together
Types Isolated, strip, combined, raft Pile, pier, well (caisson)
Suitable soil Firm soil at shallow depth Weak surface soil, waterlogged sites
Cost Generally economical Costly

Table 2: Types of Foundations and Their Uses

Foundation Type Best Used For Typical Shape
Isolated spread footing Single columns on firm soil Square or rectangular
Strip footing Load-bearing walls Continuous strip
Combined footing Two closely spaced columns Rectangular or trapezoidal
Raft / mat foundation Weak soil, heavy loads Large slab
Pile foundation Soft clay, loose sand, bridges Slender column
Well / caisson Bridge piers in river beds Hollow cylinder

6. Mind Map

flowchart TD
    A[Types of Foundations] --> B[Classification basis D/B ratio]
    A --> C[Shallow foundations]
    A --> D[Deep foundations]
    B --> B1[D/B less than or equal to 1 - shallow]
    B --> B2[D/B greater than 1 - deep]
    C --> C1[Isolated spread footing]
    C --> C2[Strip footing]
    C --> C3[Combined footing]
    C --> C4[Strap footing]
    C --> C5[Raft or mat]
    D --> D1[Pile foundations]
    D --> D2[Pier foundations]
    D --> D3[Well or caisson]
    D1 --> E1[End bearing + skin friction]
    D3 --> E2[Bridge piers, scouring rivers]
    C1 --> F1[Square 2 m x 2 m, 600 kN, 150 kN/m2]

7. Important Diagrams (SVG)

The following diagrams show the general classification of foundations and the difference between shallow and deep foundations in terms of load transfer.

Classification of Foundations FOUNDATIONS Shallow Foundations D/B <= 1 Deep Foundations D/B > 1 Isolated Strip Raft Pile Pier Well Shallow foundations transfer load through the base only. Deep foundations transfer load through base plus side friction. Golden Rule Classify any foundation by D/B ratio: shallow if equal to or below 1, deep if above 1.

Shallow vs Deep Foundation Load Path FOOTING PILE Ground level B Depth D small Load goes to soil near surface Pile length large, load reaches deep firm stratum Arrows: shallow = base pressure only; deep = side friction plus base. Golden Rule Use a deep foundation whenever shallow soil is weak, loads are heavy or scour is large.

8. Common Mistakes

  1. Many students classify a foundation by the absolute depth alone, ignoring the width; the correct criterion is the depth to width ratio D/B.
  2. A frequent error is to treat D/B = 1 exactly as deep; by the standard convention it is shallow, since shallow foundations are defined for D/B equal to or less than 1.
  3. Some candidates confuse a pier with a pile, forgetting that a pier is a large-diameter constructed column while a pile is a relatively slender driven or bored member.
  4. Students often assume that a raft foundation is a deep foundation, but a raft is a shallow foundation resting near the ground surface.
  5. A common mistake is to think that well foundations are used for small buildings; in reality they are used for heavy bridge piers where deep scour occurs.
  6. Many candidates forget that the footing must be placed at least about 50 cm below ground level to avoid the effects of weathering and topsoil movement.
  7. Some students neglect the role of skin friction in deep foundations and consider only end bearing, which leads to an incorrect capacity estimate.
  8. A frequent error is to select the footing size by dividing the load by the ultimate bearing capacity instead of the safe bearing capacity.

9. Exam Tips

  1. Memorise the classification criterion D/B equal to or less than 1 for shallow and greater than 1 for deep foundations; it is a favourite one-mark question.
  2. Remember that shallow foundations transfer load through the base only, while deep foundations use base plus skin friction.
  3. List the types under each group quickly: shallow has isolated, strip, combined, strap and raft; deep has pile, pier and well.
  4. For numerical questions, always compute the required base area as load divided by the safe bearing capacity, not the ultimate capacity.
  5. Note the thumb rule of about 50 cm minimum depth below ground for footings, which is frequently asked.
  6. Recall that a raft foundation is used when individual footings would cover more than half of the total plan area on weak soil.
  7. Practise classifying members using D/B with simple numbers, because one or two such numericals are commonly asked in CBT papers.

10. Conclusion

Foundation engineering begins with the correct identification of the type of foundation needed for a structure, and this chapter has established the fundamental framework for that decision. We have seen that foundations are classified by the depth to width ratio into shallow and deep types, that shallow foundations such as isolated, strip, combined and raft footings transmit the load near the ground surface, and that deep foundations such as piles, piers and wells carry the load to deeper and stronger strata. We have also worked out simple numerical examples showing how the depth to width ratio decides the classification and how the required base area of a footing is computed from the safe bearing capacity. A clear grasp of this classification is essential because every later topic, whether it is bearing capacity, settlement or pile design, presumes that the engineer knows which type of foundation is being analysed. The candidate should memorise the classification rule, the list of foundation types and the thumb rules given in the tables, because these facts secure quick marks and provide the conceptual anchor for the rest of foundation engineering.