Shallow Foundations

Subject: Civil Engineering Chapter: Foundation Engineering Topic: 19.2 Shallow Foundations

1. Introduction

A shallow foundation is a foundation in which the depth of the footing is generally equal to or less than its width, and the load of the structure is transferred to the soil near the ground surface. Because the load travels only a short distance through the soil, the behaviour of a shallow foundation is governed almost entirely by the strength and compressibility of the soil immediately beneath its base. Shallow foundations are the most common type of foundation in building construction, and their popularity comes from their simplicity, economy and ease of construction. For an examination candidate, shallow foundations are a high-yield topic because questions on the types of shallow footings, their design principles and simple numerical problems on contact pressure and footing sizes appear regularly in civil engineering papers.

The soil at the site must be examined before a shallow foundation is chosen, because a shallow foundation can be used only when the soil within the foundation zone has adequate bearing capacity and does not compress excessively. When the top soil is weak, expansive or disturbed, the engineer either deepens the foundation to a firmer stratum or switches to a deep foundation. The design of a shallow foundation involves two distinct checks: the foundation must be safe against shear failure, which is ensured by keeping the bearing pressure below the safe bearing capacity, and it must be safe against excessive settlement, which is ensured by limiting the average settlement and the differential settlement between different parts of the structure.

There are several forms of shallow foundations, each suited to a particular combination of loads and soil conditions. The isolated spread footing is used for a single column, the strip footing supports a continuous wall, the combined footing supports two or more columns, the strap footing links two isolated footings with a rigid beam, and the raft or mat foundation supports the entire structure on one large slab. This chapter explains each of these types, the conditions under which each is adopted, and the numerical methods used to size them, together with worked examples that illustrate the calculation of bearing pressure and the required base dimensions.

2. Isolated and Strip Footings

The isolated or spread footing is the simplest shallow foundation, consisting of a pad of reinforced concrete that spreads the column load over a larger area of soil. The footing is usually square or rectangular in plan, and its depth is governed by shear and bending requirements while its base area is governed by the safe bearing capacity of the soil. The pressure distribution under a concentrically loaded isolated footing is assumed to be uniform for design purposes, and the design bearing pressure is obtained by dividing the total vertical load by the plan area of the footing. When the column is near a property line, the footing cannot be centred, and an eccentric load develops, which produces a non-uniform pressure that is maximum at the edge nearer to the column.

A strip footing is a continuous footing that runs along the length of a wall or a row of closely spaced columns. It is designed as a long rectangular slab, and it is analysed for unit length of the wall, which makes the calculations one-dimensional. Strip footings distribute the wall load along a long narrow base so that the pressure on the soil is reduced and maintained below the safe bearing capacity. Strip footings are also used as combined footings between adjacent columns in building frames, and in such cases they are called continuous footings. The design of both isolated and strip footings requires the same fundamental rule: the pressure under the base must not exceed the safe bearing capacity, and the settlement must remain within permissible values.

Worked Example 1

A wall of thickness 300 mm transmits a load of 180 kN per metre length. The safe bearing capacity of the soil is 200 kN/m2. Determine the required width of the strip footing.

Solution:

Required base area per metre length A = load / safe bearing capacity = 180 / 200 = 0.9 m2.

Since the footing is 1 m long in plan, the width B = 0.9 / 1 = 0.9 m.

Therefore a strip footing of width 0.9 m is provided.

Worked Example 2

A square isolated footing of size 2.2 m x 2.2 m carries a total column load of 800 kN. Compute the actual bearing pressure under the footing.

Solution:

Base area A = 2.2 x 2.2 = 4.84 m2.

Bearing pressure q = load / area = 800 / 4.84 = 165.3 kN/m2.

Since 165.3 kN/m2 is less than a safe capacity of, say, 180 kN/m2, the footing is safe against shear failure.

3. Combined and Strap Footings

A combined footing supports two or more columns on a single footing and is used when the columns are so close together that their isolated footings would overlap, when one column is very close to a property line so that an isolated footing cannot be centred, or when the loads of adjacent columns are so different that isolated footings would be unequal. Combined footings are rectangular or trapezoidal in plan. A trapezoidal combined footing is provided when the outer column carries a much heavier load, because the trapezoid can be shaped so that the centroid of the footing coincides with the resultant of the column loads, which keeps the pressure distribution uniform. When the loads are nearly equal, a rectangular combined footing is economical and simple to construct.

A strap footing, also called a cantilever footing, consists of two isolated footings connected by a rigid beam or strap, which does not bear on the soil. The strap transfers the moment caused by the eccentric column load from one footing to the other, so that the pressures under both footings become uniform. Strap footings are used when the property line prevents the outer footing from being extended, and they are economical when the distance between the columns is moderate. In all combined and strap footings, the basic design requirement is that the resultant of all column loads should pass through the centroid of the contact area, so that the soil pressure remains uniform and the footing does not tilt.

Worked Example 3

Two columns carrying loads of 600 kN and 1000 kN are spaced 4 m apart on a combined rectangular footing. Determine the point where the resultant load acts from the 600 kN column.

Solution:

Total load P = 600 + 1000 = 1600 kN.

Taking moments about the 600 kN column, resultant distance x = (1000 x 4) / 1600 = 2.5 m.

For uniform pressure, the centroid of the rectangular footing must be placed at this point, 2.5 m from the 600 kN column.

Worked Example 4

For the above combined footing, if the safe bearing capacity of soil is 200 kN/m2, find the area of the footing required.

Solution:

Required area A = total load / safe bearing capacity = 1600 / 200 = 8 m2.

Therefore the combined footing is designed with a base area of 8 m2, with its centroid located on the line of action of the resultant load.

4. Raft or Mat Foundation

A raft or mat foundation is a thick reinforced concrete slab that covers the entire area beneath the structure, supporting all the columns and walls together. It is used when the soil is weak and the column loads are so heavy that individual isolated footings would occupy more than half of the total plan area, when the soil is highly compressible and differential settlement must be minimised, when the water table is high, or when the structure contains basements. Because the raft spreads the total load over the entire plan area, the bearing pressure on the soil is kept low, and because the raft acts as one rigid body, differential settlement is greatly reduced. Raft foundations are therefore very effective on soft clays and loose sands.

Raft foundations are analysed as a plate resting on the soil, and the soil is modelled as a bed of springs in the simple Winkler model, or as an elastic half-space in more refined analyses. In the simplest design, the raft is treated as an inverted floor system: the upward soil pressure replaces the downward loads, and the columns act as supports. The thickness of the raft is governed by the bending moments and shear forces, and the reinforcement is provided in both directions at top and bottom. A raft foundation is economical when a large number of isolated footings would be needed, but it becomes very costly on strong soils where a much smaller area would have sufficed, so the decision to use a raft must be based on a careful comparison of alternatives.

Worked Example 5

A raft foundation of plan area 12 m x 10 m supports a total building load of 18000 kN. Determine the average bearing pressure on the soil.

Solution:

Plan area A = 12 x 10 = 120 m2.

Average bearing pressure q = total load / area = 18000 / 120 = 150 kN/m2.

If the safe bearing capacity of the soil is 160 kN/m2, the raft is safe.

5. Quick Revision Tables

Table 1: Types of Shallow Foundations

Type Description Used When
Isolated spread footing Pad under a single column Firm soil, moderate loads
Strip footing Continuous strip under a wall Load-bearing walls
Combined footing One footing for two or more columns Close columns, property line
Strap footing Two footings joined by a rigid beam Property line restriction
Raft / mat footing One slab under whole structure Weak soil, heavy loads

Table 2: Design Checks and Numerical Relationships

Quantity Formula Example Value
Base area required A = Load / Safe bearing capacity 800/150 = 5.33 m2
Bearing pressure q = Load / Area 600/4.84 = 124 kN/m2
Resultant of two loads x = (P2 x distance)/Total load (1000 x 4)/1600 = 2.5 m
Raft pressure q = Total load / Plan area 18000/120 = 150 kN/m2
Condition for uniform pressure Resultant passes through centroid Centroid at resultant line

6. Mind Map

flowchart TD
    A[Shallow Foundations] --> B[Isolated footing]
    A --> C[Strip footing]
    A --> D[Combined footing]
    A --> E[Strap footing]
    A --> F[Raft or mat]
    B --> B1[Square or rectangular pad]
    B --> B2[A = P / q safe]
    C --> C1[Continuous under wall]
    C --> C2[Width = load per metre / q safe]
    D --> D1[Rectangular or trapezoidal]
    D --> D2[Centroid on resultant line]
    E --> E1[Rigid strap connects two pads]
    F --> F1[One slab under whole building]
    F --> F2[q = total load / plan area]
    D2 --> G[Uniform pressure condition]
    B2 --> H[Design check: q less than q safe]

7. Important Diagrams (SVG)

The following diagrams show the plan forms of the main shallow foundation types and the pressure distribution under an isolated footing.

Plan Forms of Shallow Foundations Isolated Strip / Continuous Combined Pad Pad Strap Strap footing: rigid beam joins two pads Raft / Mat: single slab under whole structure Golden Rule Choose isolated and strip footings for firm soil; switch to combined, strap or raft as loads and soil worsen.

Pressure Distribution under an Isolated Footing FOOTING B Uniform pressure q = P / A Soil reaction (sand under centric load) q must not exceed safe bearing capacity Golden Rule Always verify that the computed bearing pressure is below the safe bearing capacity of the soil.

8. Common Mistakes

  1. Many students compute the required footing area using the ultimate bearing capacity instead of the safe bearing capacity, which gives an unsafe, undersized footing.
  2. A frequent error is to ignore the self-weight of the footing and the weight of the soil above it while computing the bearing pressure.
  3. Some candidates forget the uniform pressure condition for combined footings and place the footing arbitrarily instead of making the centroid coincide with the resultant load.
  4. Students often confuse a strap footing with a combined footing, forgetting that in a strap footing the connecting beam does not bear on the soil.
  5. A common mistake is to use a raft foundation even when isolated footings cover less than half the plan area, which is uneconomical.
  6. Many candidates neglect the effect of eccentric loads near the property line, which produce non-uniform edge pressures and can cause overturning.
  7. Some students solve the wall footing problem with the total wall load instead of the load per metre length, giving a wrong width.
  8. A frequent error is to forget that the depth of a shallow footing is governed by shear and bending, not only by the soil pressure.

9. Exam Tips

  1. Remember that the base area of any shallow footing is load divided by safe bearing capacity; this single formula solves most sizing problems.
  2. Learn the thumb rule that a raft is preferred when isolated footings would cover more than half of the total plan area.
  3. Practise the resultant location formula x = (P2 x d)/Total load for combined and strap footings.
  4. Note that a strap footing's beam is designed to carry moment only, since it does not rest on the soil.
  5. Always use load per metre length while designing strip footings under walls.
  6. Remember that uniform pressure requires the resultant of loads to pass through the centroid of the footing base.
  7. Revise the types table before the exam, because one-mark questions comparing isolated, strip, combined, strap and raft footings are very common.

10. Conclusion

Shallow foundations are the workhorse of foundation engineering, and this chapter has examined all their principal forms, from the simple isolated footing to the large raft or mat slab. We have seen that every shallow foundation transmits the structural load to the soil near the ground surface, that its size is governed by the safe bearing capacity, and that its analysis reduces to simple arithmetic: base area equals load divided by safe bearing capacity, and bearing pressure equals load divided by area. The worked examples have shown how strip footings are sized for walls, how combined footings are proportioned so that the resultant passes through the centroid, and how raft foundations reduce the bearing pressure over the whole plan area. These numerical skills are directly examinable and should be practised until they become automatic. Together with the classification given in the previous chapter, this knowledge gives the candidate a complete picture of when and how to use shallow foundations, and it sets the stage for the deep foundations and bearing capacity theories that follow.