Subject: Civil Engineering Chapter: Foundation Engineering Topic: 19.3 Deep Foundations
A deep foundation is a foundation in which the depth of the foundation is large compared to its width, and in which the load of the structure is transferred to a deeper and stronger soil stratum rather than to the soil near the ground surface. Deep foundations are required when the surface soil is weak, compressible or subjected to scour, when the column loads are very heavy, when uplift or lateral forces must be resisted, or when the settlement of a shallow foundation would be excessive. Because the soil at great depth cannot be inspected directly and because the cost of a mistake is enormous, deep foundations demand careful analysis and reliable estimation of load capacity. For examination purposes, deep foundations are a frequent source of questions on classification, construction methods, load transfer mechanisms and simple capacity computations.
The principal types of deep foundations are pile foundations, pier foundations and well or caisson foundations. A pile is a slender structural member driven, bored or screwed into the ground; a pier is a large-diameter column formed by excavating a hole and filling it with concrete; and a well or caisson is a hollow box that is sunk into the ground and then filled with concrete. All three types transmit the load to the deep soil partly through the base and partly through friction along the sides, and the proportion of the load carried by each mechanism depends on the soil and the type of member. Deep foundations are used extensively in bridges, high-rise buildings, transmission towers, marine structures and structures built on soft alluvial deposits.
The choice between the various deep foundations is governed by the soil profile, the magnitude and nature of loads, the depth of the firm stratum, the availability of construction equipment and the cost. A pile foundation is economical for moderate loads and is installed rapidly, while a well foundation is preferred for very heavy bridge pier loads and for sites where large scour depths must be negotiated. This chapter explains the classification of deep foundations, the mechanisms by which they carry load, the methods of installation, and the simple numerical techniques used to estimate their capacity, illustrated with worked examples.
Piles are classified according to the material, the method of installation and the manner of load transfer. By material they may be timber, precast concrete, cast-in-situ concrete, steel or composite piles. By installation they may be driven piles, which are hammered into the ground and displace the soil, or bored piles, which are formed by drilling a hole and filling it with concrete. By load transfer they may be end-bearing piles, which rest on a hard stratum and carry the load through their tips, friction piles, which carry the load through the skin friction developed along their full length in soft soil, and combined piles, which develop resistance by both end bearing and friction. Friction piles are used in soft clays and loose sands where no firm stratum exists at a reasonable depth, while end-bearing piles are used where a hard stratum like rock lies at a moderate depth.
A pier foundation is a large-diameter cylindrical or rectangular column that is constructed in an excavated shaft and is capable of carrying very heavy loads. A pier is generally larger in diameter than a pile and is constructed by open excavation with timbering or by using drilling rigs. Pier foundations are used for heavy column loads in buildings and for bridge piers, and they are particularly suitable where a strong stratum exists at a moderate depth. A special form of pier is the under-reamed pile or pier, in which the base is enlarged into one or more bulbs, which greatly increases the bearing area and gives uplift resistance; under-reamed piles are widely used in expansive or black cotton soils in India.
A concrete pile of diameter 400 mm is driven to a depth of 10 m in a sand deposit. The soil has a friction angle of 30 degrees and the effective unit weight of soil is 18 kN/m3. Using a very simple approximation in which the point bearing resistance is 150 kN and the average skin friction is 25 kN/m2, estimate the ultimate load capacity of the pile.
Solution:
Perimeter of pile = pi x d = 3.1416 x 0.4 = 1.257 m.
Side area = perimeter x length = 1.257 x 10 = 12.57 m2.
Skin friction resistance = side area x average friction = 12.57 x 25 = 314.2 kN.
Ultimate capacity = point bearing + skin friction = 150 + 314.2 = 464.2 kN.
The ultimate load capacity of the pile is about 464 kN.
If a factor of safety of 2.5 is applied, find the safe load on the pile of Worked Example 1.
Solution:
Safe load = ultimate capacity / factor of safety = 464.2 / 2.5 = 185.7 kN.
Therefore the pile can safely carry about 186 kN.
A well foundation, also called a caisson foundation, is a hollow box or cylinder that is sunk into the ground by excavating soil from inside while the walls sink under their own weight. The well is sunk through the soil to the required depth, the bottom plug of concrete is placed, the interior is filled with sand or concrete, and a top plug and cap are provided to carry the bridge pier or superstructure. Well foundations are used for bridge piers and abutments in rivers because they can be sunk to great depths, develop large bearing and friction resistance, and are not easily affected by the scour of flowing water. The depth of a well foundation is governed by the depth of the firm stratum and by the requirement that the base must be placed below the maximum scour depth so that the well is not undermined.
The main components of a well foundation are the well curb, the steining, the bottom plug, the sand fill, the top plug, and the well cap. The curb is the bottom-most part, shaped like an inverted trapezoid, which cuts through the soil and helps the well sink. The steining is the cylindrical wall, which may be of brick, stone or reinforced concrete and provides the weight needed for sinking. The bottom plug is a concrete plug placed under water at the bottom to seal the well, the sand fill fills the interior to add weight and stability, the top plug seals the top of the sand, and the well cap spreads the superstructure load over the well. The sinking of a well is assisted by kentledge, which is dead weight placed on the top of the steining, and by the use of chisels and dredgers to excavate hard strata.
The maximum scour depth at a bridge site is 4 m, and the top of the well foundation is placed at the bed level. If the required depth of the well base below the deepest scour line is 5 m, find the total depth to which the well must be sunk.
Solution:
Total depth of sinking = maximum scour depth + depth below deepest scour = 4 + 5 = 9 m.
Therefore the well foundation is sunk to a depth of 9 m below the river bed.
A circular well foundation has an external diameter of 6 m and an internal diameter of 4 m. Determine the cross-sectional area of the steining wall.
Solution:
External area = pi x 6 x 6 / 4 = 28.27 m2.
Internal area = pi x 4 x 4 / 4 = 12.57 m2.
Area of steining = 28.27 - 12.57 = 15.7 m2.
Therefore the wall area of the steining is 15.7 m2.
The total load on a deep foundation is carried by a combination of end bearing and skin friction. In end-bearing piles, most of the load is transmitted through the tip to the hard stratum, while in friction piles the load is transmitted to the soil through the shear stress developed along the shaft. In clay soils, the skin friction is expressed in terms of the undrained cohesion, while in sands it is expressed in terms of the lateral earth pressure coefficient and the angle of wall friction. The relative contribution of the two mechanisms decides whether a pile behaves as a friction pile or an end-bearing pile, and this is established from the soil investigation report before design begins.
Comparing the deep foundation types, piles are flexible and slender, are best suited to moderate loads, and are quick to install, whereas piers are large-diameter members for very heavy loads, and wells are massive hollow members that are economical for the heaviest bridge loads and for sites with deep scour. Deep foundations are also used to resist uplift forces, as in transmission towers, and lateral forces, as in retaining walls and marine structures. The ultimate capacity of a deep foundation is verified by a pile load test, in which a test load equal to one and a half times the design load is applied in increments and the settlement is recorded, and the permissible load is taken as the smaller of the load corresponding to a specified limiting settlement and the ultimate load divided by the factor of safety.
A bored pile of diameter 500 mm and length 15 m is installed in a clay stratum having undrained cohesion of 60 kN/m2. Taking the adhesion factor as 0.5, estimate the skin friction capacity of the pile. The base resistance may be taken as 80 kN.
Solution:
Perimeter of pile = pi x 0.5 = 1.571 m.
Side area = perimeter x length = 1.571 x 15 = 23.56 m2.
Skin friction = adhesion factor x cohesion x side area = 0.5 x 60 x 23.56 = 706.9 kN.
Ultimate capacity = skin friction + base resistance = 706.9 + 80 = 786.9 kN.
Therefore the ultimate capacity of the pile is about 787 kN.
| Type | Characteristic | Main Use |
|---|---|---|
| Pile foundation | Slender member, driven or bored | Moderate loads, weak soil |
| End-bearing pile | Tip rests on hard stratum | Firm stratum at shallow depth |
| Friction pile | Load by skin friction along shaft | Soft clay, no firm stratum |
| Pier foundation | Large-diameter column | Very heavy column loads |
| Well / caisson | Hollow box sunk into ground | Bridge piers in rivers |
| Mechanism | Formula Used | Example Value |
|---|---|---|
| Skin friction (clay) | alpha x cu x perimeter x length | 0.5 x 60 x 1.571 x 15 = 707 kN |
| Skin friction (sand) | K x tan delta x sigma x side area | Depends on effective stress |
| Point / base resistance | From soil bearing theory | 150 kN given |
| Ultimate capacity | Point + skin friction | 464 kN |
| Safe load | Ultimate / factor of safety | 464/2.5 = 186 kN |
flowchart TD
A[Deep Foundations] --> B[Piles]
A --> C[Piers]
A --> D[Well / Caisson]
B --> B1[Driven or bored]
B --> B2[End bearing, friction, combined]
B3[Timber, concrete, steel] --> B
C --> C1[Large diameter, heavy loads]
C --> C2[Under-reamed for expansive soil]
D --> D1[Components: curb, steining, plugs, cap]
D --> D2[Sunk below maximum scour depth]
B --> E[Capacity = end bearing + skin friction]
E --> E1[Verify by pile load test]
D2 --> F[Depth = scour depth + depth below scour]
E2[Safe load = ultimate / FOS] --> E
The following diagrams show the components of a pile and the mechanism of load transfer in a deep foundation.
Deep foundations are the answer whenever the surface soil cannot safely carry the structure, and this chapter has covered all the important members of this family: piles, piers and wells. We have seen that deep foundations carry their loads through a combination of end bearing at the tip and skin friction along the shaft, that piles are classified by material, installation and load transfer, and that well foundations are the preferred solution for heavy bridge piers where scour is a danger. The worked examples have demonstrated the estimation of pile capacity from soil parameters, the application of the factor of safety, the computation of well sinking depth from scour considerations, and the calculation of the steining wall area. Deep foundation analysis is essentially about computing resistance from soil properties and applying suitable factors of safety, skills that are directly tested in numerical questions. With the mechanisms of load transfer and the thumb rules of well construction firmly in mind, the candidate is now ready to study the bearing capacity of soil and the theories that quantify how much load the ground can safely support.