🏗️ Civil Engineering

Bearing Capacity of Soil

Start MCQ Practice →

Bearing Capacity of Soil

Subject: Civil Engineering Chapter: Foundation Engineering Topic: 19.4 Bearing Capacity of Soil

1. Introduction

The bearing capacity of soil is the maximum average pressure that the soil can support at the base of a foundation without shear failure or excessive settlement. Every foundation problem ultimately reduces to the question of how much load the soil can safely carry, and the answer is given by the bearing capacity of the soil. When the pressure under a footing exceeds the ultimate bearing capacity, the soil beneath the footing fails by shear, the footing punches into the ground, and the structure tilts or collapses. The bearing capacity is therefore the single most important soil property in foundation design, and its evaluation is a compulsory part of any foundation engineering course and any civil engineering competitive examination.

The bearing capacity of a soil depends on the shear strength parameters of the soil, namely cohesion c and the angle of internal friction phi, on the unit weight of the soil, on the width and shape of the footing, on the depth of embedment, and on the position of the water table. A dense sand or a hard clay has a high bearing capacity, while a loose sand or a soft clay has a low bearing capacity. The terms used in bearing capacity analysis are carefully defined: the ultimate bearing capacity is the maximum pressure at which the soil fails, the net ultimate bearing capacity is the ultimate bearing capacity minus the overburden pressure at the base level, and the safe bearing capacity is the net ultimate bearing capacity divided by the factor of safety. These definitions must be memorised because they form the basis of every numerical problem.

The load-settlement behaviour of a footing shows that at low pressures the settlement is small and approximately proportional to the pressure; as the pressure increases, the settlement grows more rapidly until the soil suddenly fails, giving the ultimate bearing capacity. In some soils, especially loose sands and soft clays, the failure is gradual and the ultimate bearing capacity is taken as the pressure at which the settlement reaches a certain proportion of the footing width. This chapter explains the various modes of shear failure, the definitions of the bearing capacity terms, the factors that influence the bearing capacity, and simple numerical problems that compute the bearing capacity from given soil parameters.

2. Modes of Shear Failure

When a footing is loaded to failure, the soil beneath it can fail in one of three modes depending on the density and compressibility of the soil. The first mode is general shear failure, which occurs in dense sand and stiff clay. Here a continuous failure surface extends from one edge of the footing, passes through the soil below, and emerges at the ground surface on the other side, and the footing suddenly punches down accompanied by a bulging of the ground surface around it. General shear failure is sudden and catastrophic, and it is the mode for which the classical bearing capacity theory was developed.

The second mode is local shear failure, which occurs in loose sand and soft clay. In this mode the soil fails in a zone immediately beneath the footing only, and the failure surface does not reach the ground surface. The settlement is large but the collapse is gradual, and the ground surface bulges only slightly. The third mode is punching shear failure, which occurs in very loose or very soft soils. In this mode the footing simply punches vertically into the ground, the soil outside the footing is almost undisturbed, and there is no bulging of the ground surface. The bearing capacity in local and punching shear failure is considerably smaller than in general shear failure, and for design in such soils the shear parameters are reduced or a lower bearing capacity theory is used.

Worked Example 1

A strip footing rests on a dense sand deposit. The ultimate bearing capacity of the soil is found to be 480 kN/m2 and the effective overburden pressure at the base level is 30 kN/m2. Determine the net ultimate bearing capacity and the safe bearing capacity, using a factor of safety of 3.

Solution:

Net ultimate bearing capacity = ultimate - overburden = 480 - 30 = 450 kN/m2.

Safe bearing capacity = net ultimate / factor of safety = 450 / 3 = 150 kN/m2.

Therefore the safe bearing capacity of the soil is 150 kN/m2.

Worked Example 2

For the footing of Worked Example 1, find the safe gross bearing pressure that can be applied at the base level.

Solution:

Safe gross bearing pressure = safe bearing capacity + overburden pressure = 150 + 30 = 180 kN/m2.

Therefore the footing base may be loaded up to 180 kN/m2 gross pressure.

3. Factors Affecting Bearing Capacity

The bearing capacity of soil is influenced by a number of factors that the engineer must understand to interpret soil reports correctly. The shear strength parameters c and phi have the strongest influence: an increase in cohesion or friction angle increases the bearing capacity substantially. The width of the footing B increases the bearing capacity in sands because the friction term depends on B, but it has little effect on the cohesion term in clays. The depth of foundation increases the bearing capacity because the overburden pressure q at the base level contributes to the surcharge term of the bearing capacity equation, and for this reason deeper footings on the same soil carry more load.

The shape of the footing also matters: a square footing has a higher bearing capacity than a strip footing of the same width because of the shape factors, and a circular footing behaves similarly to a square footing. The position of the water table is very important because water reduces the effective unit weight of the soil; when the water table rises near the base of the footing, the submerged unit weight is used in the friction and surcharge terms, and the bearing capacity falls. The eccentricity of the load reduces the effective width of the footing and hence reduces the bearing capacity, and inclined loads reduce the capacity as well. Finally, the bearing capacity depends on the mode of shear failure, since general, local and punching shear failures give very different ultimate values.

Worked Example 3

A square footing of side 2 m rests at a depth of 1.5 m in a soil having cohesion 20 kN/m2, angle of internal friction 0 degrees and unit weight 18 kN/m3. Using the simplified relationship that the ultimate bearing capacity of a square footing in saturated clay is 5.7 c plus the surcharge, compute the ultimate bearing capacity.

Solution:

Overburden pressure q = unit weight x depth = 18 x 1.5 = 27 kN/m2.

Ultimate bearing capacity = 5.7 c + q = 5.7 x 20 + 27 = 114 + 27 = 141 kN/m2.

Therefore the ultimate bearing capacity is 141 kN/m2.

Worked Example 4

For the square footing of Worked Example 3, determine the net ultimate bearing capacity and the safe bearing capacity with a factor of safety of 3.

Solution:

Net ultimate bearing capacity = 141 - 27 = 114 kN/m2.

Safe bearing capacity = 114 / 3 = 38 kN/m2.

Therefore the safe bearing capacity of the soil is 38 kN/m2.

4. Water Table and Eccentricity Effects

The water table is one of the most commonly tested factors in bearing capacity problems. When the water table lies below the base of the footing by a distance greater than the width of the footing, the water has practically no effect on the bearing capacity, and the bulk unit weight of the soil is used throughout. When the water table lies at the base of the footing, the soil is submerged and the submerged unit weight is used in all the terms, and the bearing capacity is reduced. When the water table lies between the base and a depth equal to the width of the footing, an average or weighted unit weight is used. The submerged unit weight of soil is obtained by subtracting the unit weight of water from the saturated unit weight of the soil.

An eccentric load reduces the effective bearing width of a footing. The effective width is the width reduced by twice the eccentricity on the loaded side, and the bearing capacity is computed with this reduced width. For design purposes the eccentricity should be limited so that the pressure remains compressive over the whole base, which requires the eccentricity to be not greater than one sixth of the width for a rectangular footing. If the eccentricity is greater than one sixth of the width, a portion of the base separates from the soil, the pressure distribution becomes triangular, and the footing is unstable and should be redesigned.

Worked Example 5

The saturated unit weight of a soil is 20 kN/m3 and the unit weight of water is 9.81 kN/m3. Determine the submerged unit weight of the soil.

Solution:

Submerged unit weight = saturated unit weight - unit weight of water = 20 - 9.81 = 10.19 kN/m3.

Therefore the submerged unit weight is about 10.2 kN/m3.

Worked Example 6

A column load on a rectangular footing of width 3 m has an eccentricity of 0.4 m. Determine the effective width of the footing.

Solution:

Effective width = width - 2 x eccentricity = 3 - 2 x 0.4 = 3 - 0.8 = 2.2 m.

Therefore the effective width available for bearing is 2.2 m.

5. Quick Revision Tables

Table 1: Bearing Capacity Definitions

Term Definition Expression
Ultimate bearing capacity Max pressure at which soil fails q ult
Net ultimate bearing capacity q ult minus overburden at base q ult - q
Safe bearing capacity Net ultimate / factor of safety (q ult - q) / FOS
Safe gross pressure Safe net + overburden q net safe + q
Net safe load Safe net capacity x area q net safe x B x L

Table 2: Factors Affecting Bearing Capacity

Factor Effect on Bearing Capacity
Cohesion c Increases capacity (clays)
Friction angle phi Increases capacity (sands)
Footing width B Increases capacity in sands
Depth of foundation Increases capacity via surcharge
Shape (square vs strip) Square has higher capacity
Rising water table Reduces capacity (submerged weight)
Load eccentricity Reduces effective width and capacity
General vs local failure General gives higher capacity

6. Mind Map

flowchart TD
    A[Bearing Capacity of Soil] --> B[Definitions]
    A --> C[Modes of shear failure]
    A --> D[Factors affecting capacity]
    B --> B1[Ultimate, net ultimate, safe]
    B --> B2[Safe gross pressure]
    C --> C1[General shear failure]
    C --> C2[Local shear failure]
    C --> C3[Punching shear failure]
    D --> D1[Cohesion c and phi]
    D --> D2[Width and depth of footing]
    D --> D3[Shape factors]
    D --> D4[Water table position]
    D --> D5[Eccentricity of load]
    B2 --> E[FOS = 3 typical]
    C1 --> F[Dense sand, stiff clay, sudden]
    C2 --> G[Loose sand, soft clay, gradual]
    D4 --> H[Use submerged unit weight]

7. Important Diagrams (SVG)

The following diagrams show the modes of shear failure and the definitions of the bearing capacity terms.

Modes of Shear Failure Footing General shear Dense sand, sudden Footing Local shear Loose sand, gradual Footing Punching shear Very soft soil, vertical Golden Rule General shear occurs in dense soils, local and punching shear in loose and soft soils with lower capacity.

Bearing Capacity Definitions on Load-Settlement Curve Pressure on footing Settlement Safe pressure Ultimate pressure (failure) Safe bearing capacity = (q ult - q) / factor of safety Golden Rule Net ultimate capacity is ultimate minus overburden; divide it by the factor of safety to get the safe capacity.

8. Common Mistakes

  1. Many students confuse the ultimate bearing capacity with the net ultimate bearing capacity and forget to subtract the overburden pressure at the base level.
  2. A frequent error is to use the bulk unit weight of soil in the bearing capacity terms when the water table is at the base of the footing; the submerged unit weight must be used.
  3. Some candidates apply a factor of safety to the gross pressure instead of the net ultimate capacity, which gives an incorrect safe pressure.
  4. Students often assume that the bearing capacity of clay depends on the width of the footing, forgetting that in saturated clay the cohesion term is independent of width.
  5. A common mistake is to ignore the effect of the water table when it lies above the base of the footing, which overestimates the capacity.
  6. Many candidates forget the one-sixth rule: an eccentricity greater than B/6 causes tension under the footing and must be avoided.
  7. Some students mix up local and general shear failure, forgetting that local shear failure gives a lower capacity and occurs in loose sand.
  8. A frequent error is to forget that square and circular footings need shape factors and therefore have a higher capacity than strip footings.

9. Exam Tips

  1. Memorise the three terms: ultimate, net ultimate and safe bearing capacity, and practise the relation safe capacity = net ultimate / factor of safety.
  2. Remember that the standard factor of safety in bearing capacity problems is usually 2.5 to 3, most often 3.
  3. Learn the submerged unit weight formula gamma sub = gamma sat - gamma w, which is frequently needed.
  4. Note that general shear failure is associated with dense sand and stiff clay and gives the highest capacity.
  5. Recall the one-sixth rule for eccentricity in rectangular footings to ensure full contact of the base.
  6. Practise computing safe gross pressure as safe net capacity plus overburden, a very common numerical.
  7. Remember that a rising water table reduces bearing capacity, so worst-case water table position must be considered in design.

10. Conclusion

The bearing capacity of soil is the key soil property that decides the size and safety of every foundation, and this chapter has laid out its complete picture. We have seen the three modes of shear failure, general, local and punching, each occurring in a different type of soil and giving a different ultimate capacity. We have defined the ultimate, net ultimate and safe bearing capacities, and we have applied the factor of safety to convert failure pressures into usable design pressures. The worked examples have shown how the net ultimate capacity is obtained by subtracting the overburden, how the safe gross pressure is computed, how the submerged unit weight is found when the water table is present, and how eccentricity reduces the effective width of a footing. Understanding these definitions and the influence of depth, width, shape and the water table prepares the candidate directly for the quantitative theory of bearing capacity, the celebrated Terzaghi analysis, which converts these soil parameters into a compact formula that is used in design practice all over the world.