Subject: Civil Engineering Chapter: Foundation Engineering Topic: 19.5 Terzaghi Bearing Capacity Theory
The Terzaghi bearing capacity theory, proposed by Karl Terzaghi in 1943, is the foundation of modern bearing capacity analysis and the first rational theory to predict the ultimate bearing capacity of a shallow footing. Terzaghi assumed that a shallow footing fails in general shear failure, with a well-defined failure surface made of a triangular wedge beneath the footing, a radial shear zone and a passive zone on either side, and he used the equilibrium of these zones to derive a compact formula for the ultimate bearing capacity. For an examination candidate, this is one of the most heavily tested topics in foundation engineering, because direct questions on the Terzaghi equation, the bearing capacity factors, and numerical substitution problems appear in almost every civil engineering paper.
The Terzaghi equation expresses the ultimate bearing capacity as the sum of three terms: a cohesion term, a surcharge or depth term and a unit weight or width term. For a strip (continuous) footing the equation is q ult = c Nc + q Nq + 0.5 gamma B Ngamma, where c is the cohesion, q is the effective overburden pressure at the base level, gamma is the unit weight of the soil, B is the width of the footing, and Nc, Nq and Ngamma are the dimensionless bearing capacity factors which depend only on the angle of internal friction of the soil. The cohesion term is important in clays, the surcharge term is important at large depths, and the width term is important in sands where friction dominates.
Terzaghi's analysis assumed a strip footing, general shear failure, a rough base, and a foundation whose base is at or near the ground surface. For other footing shapes, correction factors are applied: a square footing uses 1.3 c Nc and 0.4 gamma B Ngamma, while a circular footing uses 1.3 c Nc and 0.3 gamma B Ngamma. For local shear failure, which occurs in loose sand, the shear strength parameters are reduced to two-thirds of their actual values. This chapter explains the derivation concept, the bearing capacity factors, the shape corrections, and the numerical application of the Terzaghi equation to strip, square and circular footings.
The Terzaghi bearing capacity equation for a strip footing is written as q ult = c Nc + q Nq + 0.5 gamma B Ngamma. Each term of this equation represents a distinct mechanism of resistance. The first term c Nc represents the resistance due to cohesion along the failure surface, and it dominates in clay soils where the angle of internal friction is zero. The second term q Nq represents the resistance due to the surcharge or overburden pressure acting at the base level of the foundation, which develops because the soil beside the foundation prevents the soil beneath it from escaping; this term increases with the depth of the foundation. The third term 0.5 gamma B Ngamma represents the resistance due to the shearing resistance and the weight of the soil within the failure zone, and it is significant only in sandy soils because it depends on the angle of internal friction.
The bearing capacity factors Nc, Nq and Ngamma depend only on the angle of internal friction phi of the soil. Nq and Nc are derived analytically from the theory of plasticity, while Ngamma is obtained partly from experiments because the exact plastic solution is difficult. For a soil with phi equal to zero, such as saturated clay under undrained conditions, Nc equals 5.7, Nq equals 1 and Ngamma equals 0, so the Terzaghi equation for a strip footing reduces to q ult = 5.7 c + q, which is the standard result for saturated clay. As the friction angle increases, all three factors increase rapidly, which is why dense sands have very high bearing capacities.
A strip footing of width 1.5 m rests at a depth of 1.2 m in a soil having cohesion c equal to 10 kN/m2, angle of internal friction phi equal to 30 degrees, and unit weight gamma equal to 18 kN/m3. The bearing capacity factors are Nc equal to 37.2, Nq equal to 22.5 and Ngamma equal to 19.7. Determine the ultimate bearing capacity.
Solution:
Overburden pressure q = gamma x depth = 18 x 1.2 = 21.6 kN/m2.
q ult = c Nc + q Nq + 0.5 gamma B Ngamma.
q ult = 10 x 37.2 + 21.6 x 22.5 + 0.5 x 18 x 1.5 x 19.7.
q ult = 372 + 486 + 266 = 1124 kN/m2.
Therefore the ultimate bearing capacity is 1124 kN/m2.
For the strip footing of Worked Example 1, find the net ultimate bearing capacity and the safe bearing capacity with a factor of safety of 3.
Solution:
Net ultimate bearing capacity = 1124 - 21.6 = 1102.4 kN/m2.
Safe bearing capacity = 1102.4 / 3 = 367.5 kN/m2.
Therefore the safe bearing capacity of the soil is about 367 kN/m2.
The basic Terzaghi equation was derived for a strip footing, so corrections are required for square and circular footings. For a square footing of side B, the ultimate bearing capacity is q ult = 1.3 c Nc + q Nq + 0.4 gamma B Ngamma. For a circular footing of diameter B, the ultimate bearing capacity is q ult = 1.3 c Nc + q Nq + 0.3 gamma B Ngamma. The factor 1.3 on the cohesion term and the coefficients 0.4 and 0.3 on the unit weight term reflect the three-dimensional effect of the soil around a square or circular footing, which provides greater confinement than a long strip footing.
When the footing is placed in loose sand or soft clay, general shear failure does not occur, and local shear failure must be assumed. Terzaghi suggested that for local shear failure the effective shear strength parameters be reduced to two-thirds of their actual values, that is c prime equal to 2c/3 and tan phi prime equal to (2/3) tan phi, and the bearing capacity factors are computed for this reduced friction angle. The resulting bearing capacity is considerably smaller than for general shear failure. In design, the condition of the soil as dense or loose must be judged from its relative density, because the same formula with unreduced parameters would overestimate the capacity of loose soils dangerously.
A square footing of side 2 m rests at a depth of 1.5 m in a soil with cohesion 25 kN/m2, phi equal to 20 degrees and unit weight 18 kN/m3. Given Nc equal to 17.7, Nq equal to 7.4 and Ngamma equal to 5.0, determine the ultimate bearing capacity.
Solution:
Overburden q = 18 x 1.5 = 27 kN/m2.
For a square footing, q ult = 1.3 c Nc + q Nq + 0.4 gamma B Ngamma.
q ult = 1.3 x 25 x 17.7 + 27 x 7.4 + 0.4 x 18 x 2 x 5.0.
q ult = 575.25 + 199.8 + 72 = 847 kN/m2.
Therefore the ultimate bearing capacity is about 847 kN/m2.
A circular footing of diameter 1.2 m rests on the ground surface in a soil having c equal to 30 kN/m2 and phi equal to 0 degrees, with gamma equal to 19 kN/m3. Compute the ultimate bearing capacity. For phi equal to 0, use Nc equal to 5.7, Nq equal to 1 and Ngamma equal to 0.
Solution:
Since the footing is at the ground surface, q = 0.
For a circular footing, q ult = 1.3 c Nc + q Nq + 0.3 gamma B Ngamma.
q ult = 1.3 x 30 x 5.7 + 0 + 0 = 222.3 kN/m2.
Therefore the ultimate bearing capacity is about 222 kN/m2.
In foundation design, the ultimate bearing capacity computed from the Terzaghi equation is converted into a usable safe value. The net ultimate bearing capacity is the ultimate bearing capacity minus the overburden pressure at the base level, q ult net = q ult - q. The safe bearing capacity is the net ultimate capacity divided by the factor of safety, and the safe gross pressure is the safe net capacity plus the overburden. The design load on the foundation must then be such that the actual bearing pressure computed as the load divided by the base area is less than the safe gross pressure, and the permissible settlement is also checked.
For a footing carrying a vertical column load, the required base area is the load divided by the safe bearing capacity, and for a square footing the side is the square root of this area. These steps convert the theoretical bearing capacity into a practical footing size, and they link the Terzaghi theory to the design of isolated footings. Because the safe bearing capacity used in practice is usually obtained from a standard penetration test correlation or a plate load test, the Terzaghi equation is used mainly for preliminary estimates and for understanding the influence of the soil parameters, but numerical problems on the equation are asked directly in examinations.
Using the safe bearing capacity of 367 kN/m2 obtained in Worked Example 2, determine the size of a square footing required to carry a column load of 1100 kN, allowing for a footing self-weight equal to 10 percent of the column load.
Solution:
Total load including self-weight = 1.1 x 1100 = 1210 kN.
Required base area = 1210 / 367 = 3.3 m2.
Side of square footing = square root of 3.3 = 1.82 m.
Therefore a square footing of side about 1.85 m is provided.
Check whether the footing of Worked Example 5, sized as 1.85 m square, keeps the actual bearing pressure below the safe gross pressure of 367 plus 21.6 equals 389 kN/m2.
Solution:
Actual base area = 1.85 x 1.85 = 3.42 m2.
Actual bearing pressure = 1210 / 3.42 = 353.8 kN/m2.
Since 353.8 is less than 389 kN/m2, the footing is safe against shear failure.
| Footing Type | Equation |
|---|---|
| Strip (continuous) | q ult = c Nc + q Nq + 0.5 gamma B Ngamma |
| Square | q ult = 1.3 c Nc + q Nq + 0.4 gamma B Ngamma |
| Circular | q ult = 1.3 c Nc + q Nq + 0.3 gamma B Ngamma |
| Saturated clay (phi = 0) | q ult = 5.7 c + q |
| Local shear (reduced) | c prime = 2c/3, tan phi prime = (2/3) tan phi |
| Friction Angle phi | Nc | Nq | Ngamma |
|---|---|---|---|
| 0 degrees | 5.7 | 1.0 | 0.0 |
| 10 degrees | 9.6 | 2.7 | 0.5 |
| 20 degrees | 17.7 | 7.4 | 5.0 |
| 30 degrees | 37.2 | 22.5 | 19.7 |
| 40 degrees | 95.7 | 81.3 | 100.4 |
flowchart TD
A[Terzaghi Bearing Capacity Theory] --> B[Assumptions]
A --> C[Equation]
A --> D[Corrections]
A --> E[Safe capacity]
B --> B1[Strip footing, general shear]
B --> B2[Rough base, shallow depth]
C --> C1[q ult = c Nc + q Nq + 0.5 gamma B Ngamma]
C1 --> C2[Cohesion term c Nc]
C1 --> C3[Surcharge term q Nq]
C1 --> C4[Unit weight term 0.5 gamma B Ngamma]
D --> D1[Square: 1.3 c Nc, 0.4 gamma B Ngamma]
D --> D2[Circular: 1.3 c Nc, 0.3 gamma B Ngamma]
D --> D3[Local shear: reduce c and tan phi by 2/3]
E --> E1[Net ultimate = q ult - q]
E --> E2[Safe = net ultimate / FOS]
The following diagrams show the failure mechanism assumed by Terzaghi and the structure of the bearing capacity equation.
The Terzaghi bearing capacity theory is the cornerstone of bearing capacity analysis and one of the most frequently examined topics in foundation engineering. In this chapter we have studied the assumptions behind the theory, the failure mechanism of the wedge, radial and passive zones, and the celebrated equation q ult = c Nc + q Nq + 0.5 gamma B Ngamma. We have seen how the three terms represent cohesion, surcharge and soil weight, how the bearing capacity factors depend only on the friction angle, and how the equation is modified for square and circular footings and for local shear failure. The worked examples have taken the reader step by step through substitution, computation of the overburden, net ultimate and safe capacities, and the final sizing of a square footing. The Terzaghi theory transforms soil parameters into an actual footing size, and this numerical skill is directly testable. With this theory mastered, the candidate can move on to the equally important subject of settlement, which checks that the foundation not only does not fail but also does not deform beyond acceptable limits.