🏗️ Civil Engineering

17.6 Permeability

Start MCQ Practice →

17.6 Permeability

Subject: Civil Engineering Chapter: Geotechnical Engineering Topic: 17.6 Permeability

1. Introduction

Permeability is the property of a soil that allows water to flow through its voids, and it is one of the most important engineering properties of soil, because the flow of water governs settlement, seepage, drainage, the stability of slopes and the safety of earth dams. A soil through which water flows easily is said to be highly permeable, while a soil that resists the flow of water is said to be impermeable or of low permeability. Gravels and sands have high permeability and drain freely, while silts and clays have very low permeability and drain slowly. The knowledge of the permeability of a soil is needed for computing the quantity of water seeping under a dam, for designing filters and drains, for calculating the rate of settlement of a clay layer, and for designing dewatering systems for excavations.

The flow of water through soil obeys Darcy's law, which states that the velocity of flow is proportional to the hydraulic gradient. The constant of proportionality is the coefficient of permeability, denoted by k, and it is the most important parameter in seepage calculations. The coefficient of permeability is determined in the laboratory by the constant head permeability test, which is suitable for coarse-grained soils, and by the falling head permeability test, which is suitable for fine-grained soils. In the field, pumping tests are used to determine the permeability of large deposits. The permeability of a soil depends on the grain size, the void ratio, the viscosity of the fluid, the degree of saturation and the soil structure.

In this chapter we will study Darcy's law and the definition of the coefficient of permeability, the factors affecting permeability, the laboratory methods of determination, the constant head and falling head tests with their formulas, the field pumping tests, and the concept of permeability of stratified soil deposits. Each method is illustrated with worked numerical examples, because numerical problems on the permeability tests appear regularly in competitive examinations.

2. Darcy's Law and Coefficient of Permeability

In 1856 the French engineer Henry Darcy conducted experiments on the flow of water through sand and established that the discharge Q through a soil sample is directly proportional to the cross-sectional area A and to the hydraulic gradient i, and inversely proportional to the length of the sample. Darcy's law is written as Q = k i A, where k is the coefficient of permeability. The hydraulic gradient i is the ratio of the head loss h to the length of flow L, i = h/L, so the discharge can also be written as Q = k A h / L. The velocity of flow, called the discharge velocity, is v = Q/A = k i, and the actual seepage velocity vs is higher than the discharge velocity, because the water flows only through the voids, so vs = v/n, where n is the porosity.

Darcy's law is valid for laminar flow, which occurs in most soils, but it ceases to hold in very coarse gravels and boulders where the flow is turbulent, and in very fine clays where surface forces become important. The coefficient of permeability k has the units of velocity, expressed in cm/s or m/s. The coefficient of permeability of a clean gravel may be of the order of 1 cm/s, that of a sand from 10^-2 to 10^-3 cm/s, that of silt from 10^-3 to 10^-5 cm/s, and that of clay as low as 10^-7 to 10^-9 cm/s. The enormous range of permeability, from gravel to clay over many orders of magnitude, explains why clays drain so slowly and consolidate for years.

Worked Example 1: A sand sample of cross-sectional area 20 cm2 and length 10 cm is tested in a constant head permeameter. The head is kept constant at 50 cm and the discharge collected in 60 seconds is 600 cm3. Determine the coefficient of permeability. Solution: Hydraulic gradient i = h/L = 50/10 = 5. Discharge Q = 600/60 = 10 cm3/s. Darcy's law gives k = Q/(i A) = 10/(5 x 20) = 10/100 = 0.1 cm/s. Hence the coefficient of permeability of the sand is 0.1 cm/s.

3. Factors Affecting Permeability

The permeability of a soil depends on several factors, of which the most important are the grain size, the void ratio and the viscosity of the fluid. The permeability is approximately proportional to the square of the effective grain size D10, as given by Allen Hazen's formula k = C (D10)2, where C is a constant that varies from about 100 to 150 when D10 is in cm and k is in cm/s. This formula holds for fairly uniform sands and shows that a small increase in the grain size produces a large increase in the permeability. The permeability also increases with the void ratio, because a higher void ratio means larger and more continuous voids, and for sands the relation k is proportional to e squared divided by (1 + e) has been suggested.

The permeability depends on the properties of the permeating fluid, since k = K rho g / mu, where rho and mu are the density and viscosity of the fluid and K is the intrinsic permeability of the soil, which depends only on the soil. Since the viscosity of water decreases with temperature, the permeability of a soil increases with the temperature of the water. For this reason, in the standard tests the permeability is corrected to the value at 20 degrees Celsius by the relation k20 = kT x muT/mu20, where muT and mu20 are the viscosities at the test temperature and at 20 degrees Celsius. The degree of saturation also affects the permeability; a partially saturated soil has air in the voids, which blocks the water passages and reduces the permeability.

The structure of the soil also matters. A flocculated clay, in which the particles arrange edge to face, has a higher permeability than a dispersed clay, in which the particles arrange face to face, for the same void ratio. In a stratified deposit, the permeability in the horizontal direction is different from that in the vertical direction. The presence of entrapped air, organic matter and cementation also reduces the permeability. For field problems the permeability of a large deposit is best found by pumping tests, because laboratory samples are small and may not represent the stratification and fissures of the natural ground.

4. Laboratory and Field Determination of Permeability

The constant head permeability test is used for coarse-grained soils and is performed in the constant head permeameter. In this test a sample of known cross-sectional area A and length L is kept in a cylinder, a constant head h is maintained by an overflow arrangement, and the quantity Q of water collected in time t is measured. The coefficient of permeability is k = Q L / (A h t), where the head loss is h. The falling head permeability test is used for fine-grained soils, in which the discharge is too small to measure conveniently. In this test a standpipe of area a is connected to the sample, the initial head is h1 at time t1 and the final head is h2 at time t2, and the coefficient of permeability is k = (2.303 a L / (A t)) x log10(h1/h2), where t is the time interval between the readings.

In the field, the permeability of a deposit is determined by pumping tests. In an unconfined aquifer, a well is pumped at a steady discharge Q and the drawdown is measured in observation wells; the permeability is k = (Q / pi (h2 squared - h1 squared)) x ln(r2/r1), where h1 and h2 are the water levels in the observation wells at radii r1 and r2. In a confined aquifer the formula is k = (Q / (2 pi b (h2 - h1))) x ln(r2/r1), where b is the thickness of the aquifer. The pumping test measures the field permeability over a large volume of soil and is therefore more reliable than the laboratory test for a natural deposit.

Worked Example 2: In a falling head test, a sample of length 10 cm and area 30 cm2 is connected to a standpipe of area 1 cm2. The head falls from 80 cm to 40 cm in 20 minutes. Determine the coefficient of permeability. Solution: k = (2.303 a L / (A t)) log10(h1/h2) = (2.303 x 1 x 10 / (30 x 20 x 60)) x log10(80/40) = (23.03/36000) x 0.3010 = 6.397 x 10^-4 x 0.3010 = 1.926 x 10^-4 cm/s. Hence the coefficient of permeability is about 1.93 x 10^-4 cm/s, which is typical of a fine sand or silt.

5. Quick Revision Tables

Table 1: Permeability of Different Soils

Soil type Coefficient of permeability (cm/s) Drainage
Gravel More than 1 Excellent
Sand 10^-2 to 10^-3 Good
Silt 10^-3 to 10^-5 Poor
Clay 10^-7 to 10^-9 Very poor

Table 2: Permeability Tests

Test Suitable soil Formula
Constant head test Coarse-grained k = QL/(Aht)
Falling head test Fine-grained k = (2.303 aL/(At)) log10(h1/h2)
Pumping test (unconfined) Field deposit k = (Q/(pi(h2^2 - h1^2))) ln(r2/r1)
Pumping test (confined) Field aquifer k = (Q/(2 pi b(h2 - h1))) ln(r2/r1)

6. Mind Map

flowchart TD
    A[Permeability] --> B[Darcy's law]
    A --> C[Factors affecting permeability]
    A --> D[Laboratory tests]
    A --> E[Field tests]
    A --> F[Permeability of stratified soils]
    B --> B1[Q = k i A]
    B --> B2[v = k i discharge velocity]
    B --> B3[vs = v/n seepage velocity]
    B --> B4[Valid for laminar flow]
    C --> C1[Grain size - Hazen k = C D10 squared]
    C --> C2[Void ratio]
    C --> C3[Fluid viscosity and temperature]
    C --> C4[Degree of saturation]
    C --> C5[Soil structure]
    D --> D1[Constant head test - coarse soils]
    D --> D2[Falling head test - fine soils]
    E --> E1[Pumping test unconfined]
    E --> E2[Pumping test confined]
    F --> F1[Horizontal permeability of layers]
    F --> F2[Vertical permeability of layers]
    F1 --> F1a[kh = sum(ki Hi)/sum(Hi)]
    F2 --> F2a[kv = sum(Hi)/sum(Hi/ki)]

7. Important Diagrams (SVG)

The following diagrams show the constant head permeability test and the falling head permeability test used in the laboratory.

Constant Head Permeability Test Water supply tank Overflow outlet Water Soil sample Length L, area A Cup Head h Q cm3 in t seconds k = Q L / (A h t) Golden Rule Constant head test is for coarse soils; use k = QL/(Aht) with a steady head.

Falling Head Permeability Test Standpipe area a h1 at time t1 h2 at time t2 Soil sample Length L, area A Porous plate Collector k = (2.303 a L / (A t)) log10(h1/h2) Golden Rule Falling head test is for fine soils; use the log ratio of initial and final heads.

8. Common Mistakes

  1. Many students confuse the discharge velocity with the seepage velocity; the seepage velocity is higher because water flows only through the voids, so vs = v/n and never vs = v.
  2. A frequent error is to forget that Darcy's law applies to laminar flow only; in coarse gravels where flow is turbulent the law breaks down.
  3. Some candidates use the constant head formula for a fine-grained soil; the constant head test gives too small a discharge for fine soils, and the falling head test must be used.
  4. Students often ignore the correction of permeability to 20 degrees Celsius; since viscosity changes with temperature, the measured permeability must be corrected to a standard temperature.
  5. A common mistake is to think that permeability increases with the viscosity of the fluid; in fact k = K rho g/mu, so a higher viscosity reduces the permeability.
  6. Many candidates forget that Hazen's formula k = C(D10)2 applies to fairly uniform sands only, and that the effective size D10 must be in cm for the usual value of the constant.
  7. Some students use the volume collected in the falling head formula instead of the head ratio; the falling head formula uses the ratio of heads in a logarithm, not the collected volume.
  8. Another recurring error is to neglect the temperature of the water in pumping tests; the field permeability must also be corrected to 20 degrees Celsius for comparison with laboratory values.

9. Exam Tips

  1. Memorise Darcy's law in all three forms, Q = k i A, v = k i and i = h/L, because numericals on permeability begin from one of these.
  2. Remember the typical order of permeability: gravel above 1 cm/s, sand 10^-2 to 10^-3 cm/s, silt 10^-3 to 10^-5 cm/s, and clay 10^-7 to 10^-9 cm/s.
  3. In the constant head test use k = QL/(Aht), and in the falling head test use k = (2.303 aL/(At)) log10(h1/h2); both are directly asked.
  4. Correct the permeability to 20 degrees Celsius using the viscosity ratio whenever the test temperature differs from the standard temperature.
  5. Use Hazen's formula k = C(D10)2 with C between 100 and 150 for clean uniform sands, and check that D10 is in cm.
  6. For stratified deposits remember that the equivalent horizontal permeability is the weighted average of the layer permeabilities, while the equivalent vertical permeability uses the harmonic mean.
  7. Remember that a pumping test measures the field permeability over a large volume and is more reliable than a laboratory test for natural deposits with stratification and fissures.

10. Conclusion

Permeability governs the movement of water through soil, and through that movement it controls the drainage, settlement and stability of nearly every geotechnical structure. In this chapter we have studied Darcy's law and the coefficient of permeability, the factors that influence permeability such as grain size, void ratio, viscosity, temperature and soil structure, and the laboratory and field methods of determination. We have derived and applied the constant head formula for coarse-grained soils, the falling head formula for fine-grained soils, and the pumping test formulas for unconfined and confined aquifers, and we have noted the enormous range of permeability values from gravel to clay. The concept of seepage velocity and the treatment of stratified deposits complete the picture. The coefficient of permeability determined here is the key input for the next chapter, which studies the flow of water through the ground in the form of seepage and flow nets, and for the analysis of effective stress and settlement in the chapters that follow.