Subject: Civil Engineering Chapter: Hydraulics & Hydraulic Machines Topic: 12.7 Hydraulic Turbines
A hydraulic turbine is a prime mover that converts the energy of flowing water into mechanical energy of rotation, which is then converted into electrical energy by an alternator in a hydroelectric power station. The energy of water stored in a reservoir is entirely potential energy, which changes into kinetic energy as the water descends through the penstock, and the turbine extracts this energy by allowing the water to act upon the vanes or blades of a runner. For a civil engineering candidate preparing for competitive examinations, hydraulic turbines are a high-yield topic because questions on the classification of turbines, the Pelton, Francis and Kaplan machines, and the numerical computation of power, head and discharge appear in almost every paper.
Hydraulic turbines are broadly divided into impulse turbines and reaction turbines. In an impulse turbine, such as the Pelton wheel, the entire pressure energy of the water is first converted into kinetic energy in a nozzle before the jet strikes the buckets, and the pressure at the turbine runner is atmospheric. In a reaction turbine, such as the Francis and Kaplan turbines, the water enters the runner with some pressure energy which is partly converted into kinetic energy as it flows through the runner, and the runner operates under a pressure greater than atmospheric.
In this chapter we will study the classification of turbines, the construction and working of the Pelton, Francis and Kaplan turbines, the important quantities of head, discharge, power and efficiency, and the numerical computation of the work done by a jet on a moving plate and the power developed by a Pelton wheel. The concepts of specific speed and unit quantities, which are used to select a turbine for a given head and discharge, are introduced here and developed further in the chapter on turbine performance.
Hydraulic turbines are classified on the basis of the type of energy at the inlet, the direction of flow of water, the head under which they operate and the specific speed. On the basis of the energy available at the inlet, turbines are impulse turbines, which use only the kinetic energy of a high-speed jet, and reaction turbines, which use both pressure energy and kinetic energy. On the basis of the direction of flow through the runner, turbines are classified as tangential flow, radial flow, axial flow and mixed flow.
The Pelton wheel is a tangential flow impulse turbine used for very high heads ranging from about 150 m to more than 1000 m. The Francis turbine is a mixed flow reaction turbine used for medium heads ranging from about 30 m to 500 m, in which the water enters the runner radially and leaves axially. The Kaplan turbine is an axial flow reaction turbine used for low heads from about 2 m to 70 m, with large discharges, and it resembles a ship's propeller with adjustable blades. The propeller turbine is similar to the Kaplan turbine but has fixed blades.
The choice of a turbine for a given site depends on the available head and discharge. High heads with small discharges suit the Pelton wheel, medium heads and medium discharges suit the Francis turbine, and low heads with large discharges suit the Kaplan turbine. The specific speed, which combines head, power and speed in a single number, is used as the quantitative basis of this selection, with the Pelton wheel having the lowest specific speed and the Kaplan turbine the highest.
The Pelton wheel consists of a runner carrying a set of double-cup shaped buckets, a nozzle that converts the pressure energy of the water into a high-speed jet, and a spear valve or needle valve inside the nozzle to regulate the discharge and to control the jet. The jet strikes the splitter ridge at the centre of the bucket, divides into two parts and flows around the two cups, leaving the buckets in a direction nearly opposite to that of the incoming jet. This reversal of the direction of the jet produces a large change of momentum and hence a large force on the buckets.
The velocity of the jet is obtained from the head by the relation V1 = Cv sqrt(2 g H), where Cv is the coefficient of velocity, usually about 0.98, and H is the net head at the base of the nozzle. The peripheral velocity of the wheel is u = (pi D N)/60, where D is the pitch diameter of the wheel and N is the speed in revolutions per minute. The hydraulic efficiency is maximum when the velocity ratio u/V1 equals 0.5, at which the jet is deflected through 180 degrees and the theoretical efficiency reaches its highest value.
Numerical Example: A Pelton wheel develops 3000 kW under a net head of 200 m at a speed of 500 rpm. The coefficient of velocity is 0.98 and the speed ratio is 0.46. Taking g = 9.81 m/s squared and the efficiency of the wheel as 0.88, find the diameter of the jet and the diameter of the wheel.
Solution: Jet velocity V1 = 0.98 x sqrt(2 x 9.81 x 200) = 0.98 x sqrt(3924) = 0.98 x 62.64 = 61.39 m/s. Peripheral velocity u = 0.46 x 61.39 = 28.24 m/s. Wheel diameter D = 60 u/(pi N) = 60 x 28.24/(pi x 500) = 1.078 m. Discharge Q = P/(rho g H eta) = 3000 x 1000/(1000 x 9.81 x 200 x 0.88) = 3000000/1726560 = 1.737 cubic metres per second. Area of jet A = Q/V1 = 1.737/61.39 = 0.0283 square metres, so the jet diameter d = sqrt(4 A/pi) = sqrt(0.036) = 0.19 m. The wheel diameter is 1.078 m and the jet diameter is 0.19 m.
In a reaction turbine the water enters the runner under pressure and fills the entire casing, so that the whole periphery of the runner is wetted. The Francis turbine consists of a spiral casing of decreasing cross-section, a ring of stationary guide vanes, a runner with curved vanes, and a draft tube. The water enters the spiral casing, is directed onto the runner by the guide vanes, flows radially inward through the runner, and leaves axially through the draft tube, which converts the velocity energy at the runner outlet into pressure energy and allows the runner to be placed above the tailwater level.
The guide vanes regulate the discharge and, together with the flow control, adjust the angle of entry of the water. In a Francis turbine the guide vanes are fixed for a given load, while in a Kaplan turbine both the guide vanes and the runner blades can be adjusted, which is why the Kaplan turbine maintains high efficiency over a wide range of loads and discharges. The axial flow runner of the Kaplan turbine is shaped like a propeller, with the water flowing parallel to the axis of rotation.
The velocity triangles at the inlet and outlet of the runner are used to analyse the work done by the water on the runner. The Euler turbine equation gives the work done per unit weight as w = (1/g)(Vw1 u1 - Vw2 u2), where Vw1 and Vw2 are the whirl components of the absolute velocity at inlet and outlet and u1 and u2 are the peripheral velocities. For maximum efficiency the outlet whirl velocity Vw2 is made zero, so that all the momentum of the water is extracted by the runner.
Numerical Example: In a Francis turbine the runner diameter is 1.2 m and the speed is 375 rpm. Water enters the runner radially with a velocity of flow of 8 m/s at the inlet, and the guide vane angle at the inlet is 30 degrees. Find the inlet whirl velocity and the power developed per unit weight of flow. Take g = 9.81 m/s squared.
Solution: Peripheral velocity u = pi D N/60 = pi x 1.2 x 375/60 = 23.56 m/s. At the inlet, tan(30) = Vf1/(u1 - Vw1) is not directly applicable; instead for radial entry of the water the whirl velocity Vw1 = u1 - Vf1 cot(30) is wrong. Correctly, since the flow enters radially, Vf1 = V1 sin(alpha) and Vw1 = V1 cos(alpha), with tan(alpha) = Vf1/(Vw1) and u1 = Vw1 + Vf1/tan(beta). Given the guide vane angle alpha = 30 degrees, Vf1 = V1 sin 30 and Vw1 = V1 cos 30, so V1 = Vf1/sin 30 = 8/0.5 = 16 m/s and Vw1 = 16 x cos 30 = 13.86 m/s. Work done per unit weight w = u1 Vw1/g = 23.56 x 13.86/9.81 = 33.28 m. The inlet whirl velocity is 13.86 m/s and the work done per unit weight of water is 33.28 m.
| Feature | Pelton wheel | Francis turbine | Kaplan turbine |
|---|---|---|---|
| Type | Impulse, tangential | Reaction, mixed flow | Reaction, axial flow |
| Head range | 150 to 1000 m | 30 to 500 m | 2 to 70 m |
| Discharge | Low | Medium | High |
| Specific speed | Lowest | Medium | Highest |
| Blade adjustment | Fixed buckets | Fixed guide vanes | Adjustable blades |
| Quantity | Formula | Remarks |
|---|---|---|
| Jet velocity | V1 = Cv sqrt(2 g H) | Cv about 0.98 |
| Peripheral velocity | u = pi D N/60 | Pitch diameter D |
| Speed ratio | V1/u optimum = 2 | u = 0.5 V1 for max efficiency |
| Euler equation | w = (Vw1 u1 - Vw2 u2)/g | Work per unit weight |
| Hydraulic power | P = rho g Q H | In watts |
| Overall efficiency | eta = P/(rho g Q H) | Output over input |
flowchart TD
A[Hydraulic Turbines] --> B[Impulse turbines]
A --> C[Reaction turbines]
A --> D[Pelton wheel]
A --> E[Francis turbine]
A --> F[Kaplan turbine]
B --> B1[Kinetic energy of jet only]
B --> B2[Pressure atmospheric]
C --> C1[Pressure plus kinetic energy]
C --> C2[Draft tube used]
D --> D1[High head, low discharge]
D --> D2[Spear valve control]
E --> E1[Medium head, radial inflow]
F --> F1[Low head, large discharge]
F --> F2[Adjustable runner blades]
D --> G[V1 = Cv sqrt(2 g H)]
The following diagrams show the arrangement of a Pelton wheel with the jet striking the buckets and the layout of a Francis reaction turbine with its draft tube.
Hydraulic turbines are the machines that harness the energy of flowing water for power generation, and a correct understanding of their classification and working is essential for the hydraulics paper. In this chapter we have studied the division of turbines into impulse and reaction machines, the construction and working of the Pelton wheel for high heads, the Francis turbine for medium heads and the Kaplan turbine for low heads, and the functions of the nozzle, guide vanes, runner and draft tube. The jet velocity formula, the Euler turbine equation and the power equation have been used in worked numerical examples to compute the dimensions and performance of a Pelton wheel and a Francis turbine. The specific speed and the velocity triangles introduced here are the foundation of the detailed performance analysis of turbines, which is treated in the final chapter of this series. A candidate who remembers the classification, the head ranges and the governing equations will find the turbine questions among the most predictable marks in the examination.