🏗️ Civil Engineering

12.9 Reciprocating Pumps

Start MCQ Practice →

12.9 Reciprocating Pumps

Subject: Civil Engineering Chapter: Hydraulics & Hydraulic Machines Topic: 12.9 Reciprocating Pumps

1. Introduction

A reciprocating pump is a positive displacement pump that lifts water by the to-and-fro motion of a piston inside a cylinder, and it is used where a small discharge is required against a very high head, such as in boiler feeding, hydraulic presses, oil fields and high-pressure testing. Unlike the centrifugal pump, which depends on the high-speed rotation of an impeller, the reciprocating pump delivers a fixed quantity of liquid in every stroke, so its discharge is largely independent of the head. For a civil engineering candidate preparing for competitive examinations, the reciprocating pump is examined through its construction, the single-acting and double-acting arrangements, the slip, and the computation of discharge and power required.

The pump consists of a cylinder, a piston or plunger, a connecting rod driven by a crank, two suction valves and two delivery valves. During the suction stroke the piston moves outward, the suction valve opens and water enters the cylinder from the sump, and during the delivery stroke the piston moves inward, the delivery valve opens and the water is forced into the delivery pipe. The valves are one-way or non-return valves, so that the direction of flow of the water is always controlled. The pump is called single-acting when it discharges water only during the delivery stroke and double-acting when it discharges during both strokes.

In this chapter we will study the construction and working of a reciprocating pump, the single-acting and double-acting arrangements, the computation of the discharge and the work done, and the concepts of slip, negative slip and coefficient of discharge. Worked numerical examples show the computation of discharge and power for both single-acting and double-acting pumps, together with the analysis of the acceleration head and friction head in the suction and delivery pipes.

2. Single-Acting and Double-Acting Reciprocating Pumps

In a single-acting reciprocating pump, the piston performs one suction stroke and one delivery stroke for each revolution of the crank, so that water is delivered only during one half of each revolution. If A is the cross-sectional area of the piston and L is the length of the stroke, the volume of water delivered per stroke is A L, and the theoretical discharge for N revolutions per second is Q theoretical = A L N. In practice the discharge during the suction stroke is zero, so the flow in the delivery pipe is intermittent unless an air vessel is fitted.

In a double-acting pump, the water is delivered during both the forward and the backward strokes of the piston. The delivery on one side of the piston takes place during the suction on the other side, so the pump delivers A L N during each revolution, where the effective area is the full piston area for one stroke and the piston area minus the piston rod area for the other stroke. If the area of the piston rod is neglected, the theoretical discharge of a double-acting pump is Q theoretical = 2 A L N, twice that of a single-acting pump running at the same speed.

The actual discharge of a reciprocating pump is always somewhat less than the theoretical discharge because of the leakage of water past the piston and the valves and because the valves do not open and close instantly. The difference between the theoretical and the actual discharge is called the slip of the pump, slip = Q theoretical - Q actual. The ratio of the actual discharge to the theoretical discharge is called the coefficient of discharge, Cd = Q actual/Q theoretical, and the slip may also be expressed as a percentage of the theoretical discharge.

3. Discharge and Work Done by a Reciprocating Pump

The theoretical discharge of a single-acting pump is Q = A L N = (pi D squared L N)/4, where D is the diameter of the cylinder, L is the length of the stroke and N is the speed in revolutions per second. For a double-acting pump the discharge is Q = 2 A L N, neglecting the area of the piston rod. The work done per second in a single-acting pump is the product of the weight of water lifted per second and the total head, W = (rho g A L N)(Hs + Hd), where Hs is the suction head and Hd is the delivery head. For a double-acting pump the same work is computed with the doubled discharge.

The power required to drive the pump is obtained by dividing the work done per second by the efficiency of the pump. In practice the actual head against which the pump works includes the friction losses in the suction and delivery pipes and the acceleration heads, so the indicator diagram of the pump shows a rounded rather than a rectangular area. The indicator diagram is the plot of the pressure in the cylinder against the stroke of the piston, and its area gives the work done per stroke.

Numerical Example: A single-acting reciprocating pump has a cylinder of diameter 150 mm and a stroke of 300 mm, and it runs at a speed of 30 rpm. The suction head is 4 m and the delivery head is 15 m. Find the theoretical discharge and the power required, taking the density of water as 1000 kg/m cubed and g as 9.81 m/s squared.

Solution: Piston area A = pi x 0.15 x 0.15/4 = 0.01767 square metres. N = 30/60 = 0.5 revolutions per second. Discharge Q = A L N = 0.01767 x 0.3 x 0.5 = 0.00265 cubic metres per second = 2.65 litres per second. Total head = Hs + Hd = 4 + 15 = 19 m. Work done per second = rho g Q (Hs + Hd) = 1000 x 9.81 x 0.00265 x 19 = 494 W = 0.494 kW. The theoretical discharge is 0.00265 cubic metres per second and the power required is 0.494 kW.

4. Air Vessels, Acceleration Head and Indicator Diagram

The discharge of a reciprocating pump is not uniform, because the water is delivered only during part of the cycle, and this causes vibrations and surges in the pipe lines. An air vessel is a closed chamber fitted to the suction and delivery pipes near the pump, containing a cushion of compressed air, which absorbs the excess water during the delivery stroke and returns it during the suction stroke. With air vessels, the flow in the pipes becomes nearly uniform, the acceleration head is greatly reduced, and the pump can be run at a higher speed without separation of the water column.

During the suction stroke the piston accelerates the water in the suction pipe, so that a part of the pressure head is used to accelerate the water column, and during the delivery stroke a similar acceleration head appears in the delivery pipe. The acceleration head at the beginning of the stroke is given by h acceleration = (L pipe/g)(A/A pipe)(omega squared r) cos(theta), where L pipe is the length of the pipe, A/A pipe is the ratio of the piston area to the pipe area, omega is the angular velocity of the crank and r is the crank radius. The maximum acceleration head occurs when the crank is at the beginning of the stroke.

The indicator diagram of a reciprocating pump is the graphical record of the pressure inside the cylinder at every position of the piston, and its area represents the work done during the stroke. Without air vessels the diagram is rectangular, while with the acceleration heads the ends are rounded off. The diagram is used to compute the power required, to design the crank mechanism and to judge whether separation of the water column will occur. Separation occurs when the pressure in the cylinder falls below the vapour pressure of the water, which breaks the continuity of the water column and stops the suction.

5. Quick Revision Tables

Table 1: Single-Acting versus Double-Acting Pumps

Feature Single-acting pump Double-acting pump
Delivery strokes per revolution One Two
Theoretical discharge Q = A L N Q = 2 A L N
Flow in delivery pipe Intermittent More uniform
Air vessel Often required Often required
Work done per second rho g A L N (Hs + Hd) rho g 2 A L N (Hs + Hd)

Table 2: Terms Related to Reciprocating Pumps

Term Definition Formula
Slip Theoretical discharge minus actual discharge Q theoretical - Q actual
Negative slip When actual discharge exceeds theoretical Occurs with long delivery pipe
Coefficient of discharge Actual / theoretical discharge Cd = Q actual/Q theoretical
Acceleration head Head used to accelerate water column Depends on crank angle
Air vessel Chamber with air cushion Smooths the flow

6. Mind Map

flowchart TD
    A[Reciprocating Pumps] --> B[Construction]
    A --> C[Single-acting]
    A --> D[Double-acting]
    A --> E[Discharge and work]
    A --> F[Special terms]
    B --> B1[Cylinder and piston]
    B --> B2[Suction and delivery valves]
    B --> B3[Crank and connecting rod]
    C --> C1[Q = A L N]
    C --> C2[One delivery stroke per revolution]
    D --> D1[Q = 2 A L N]
    D --> D2[Delivery on both strokes]
    E --> E1[Work = rho g Q (Hs + Hd)]
    E --> E2[Power = work / efficiency]
    F --> F1[Slip]
    F --> F2[Negative slip]
    F --> F3[Air vessels]
    F --> F4[Acceleration head]

7. Important Diagrams (SVG)

The following diagrams show the layout of a single-acting reciprocating pump and the indicator diagram of the pump with the suction and delivery strokes.

Single-Acting Reciprocating Pump Cylinder Piston Crank Suction Delivery Delivery pipe Suction pipe Q = A L N for a single-acting pump Golden Rule A reciprocating pump is a positive displacement pump delivering a fixed volume per stroke.

Ideal Indicator Diagram of a Reciprocating Pump Stroke length Pressure head Delivery head (Hd) Suction head (Hs) Area of rectangle = work done per stroke = rho g A L (Hs + Hd) Golden Rule The area of the indicator diagram gives the work done during each stroke of the pump.

8. Common Mistakes

  1. Many students use the double-acting discharge formula Q = 2 A L N for a single-acting pump, overestimating the discharge by a factor of two.
  2. A frequent error is to forget that N in the discharge formula must be in revolutions per second, not revolutions per minute.
  3. Some candidates neglect the area of the piston rod in a double-acting pump and then wonder why the computed discharge is too large.
  4. Students often confuse slip with negative slip, forgetting that negative slip occurs when the actual discharge exceeds the theoretical discharge due to inertia effects in a long delivery pipe.
  5. A common mistake is to compute the work done using the static head only, without adding the friction losses and the acceleration heads.
  6. Many candidates believe the flow of water in the delivery pipe is uniform, but without an air vessel it is intermittent and pulsating.
  7. Some students forget that the valves of a reciprocating pump are non-return or one-way valves, and assume water flows through them in both directions.
  8. Another recurring error is to treat the coefficient of discharge as the ratio of theoretical to actual discharge instead of actual to theoretical.

9. Exam Tips

  1. Memorise the discharge formulas: single-acting Q = A L N and double-acting Q = 2 A L N, with N in revolutions per second.
  2. Remember the work done per second is W = rho g Q (Hs + Hd) and the power is obtained by dividing by the efficiency.
  3. Define slip as Q theoretical - Q actual and remember negative slip is possible with a long delivery pipe.
  4. Note the coefficient of discharge is Cd = Q actual/Q theoretical, always less than or equal to 1 except under negative slip.
  5. Learn that an air vessel smooths the flow and reduces the acceleration head in both the suction and the delivery pipes.
  6. Recall that the acceleration head depends on the crank angle and is maximum at the beginning of the stroke.
  7. The area of the indicator diagram represents the work done per stroke of the pump.
  8. In numerical questions, convert all dimensions to metres and the speed to revolutions per second before substitution.

10. Conclusion

The reciprocating pump is the classic example of a positive displacement pump, delivering a fixed volume of liquid per stroke regardless of the head against which it works. In this chapter we have studied the construction of the pump with its cylinder, piston, crank and non-return valves, the working of the single-acting and double-acting arrangements, and the formulas for the theoretical discharge of each type. The concepts of slip, negative slip and the coefficient of discharge have been defined, and the work done per second and the power required have been computed in a worked example. The acceleration head, the air vessel and the indicator diagram have been explained, showing how the pump behaves dynamically and how the flow can be made more uniform. The reciprocating pump is used where high heads and small discharges are required, complementing the centrifugal pump studied in the previous chapter, and together they provide the complete picture of pumping machinery that is examined in the final chapter on pump and turbine performance.