🏗️ Civil Engineering

13.3 Rainfall Measurement

Start MCQ Practice →

13.3 Rainfall Measurement

Subject: Civil Engineering Chapter: Hydrology Topic: 13.3 Rainfall Measurement

1. Introduction

Rainfall is the primary source of water for all surface and groundwater resources, and accurate measurement of rainfall is therefore the most fundamental activity in hydrology. The instrument used to measure rainfall at a point is called a rain gauge, and the data collected from a network of rain gauges over a catchment are used to estimate the areal average rainfall, which in turn is used to estimate runoff, design drains and spillways, and plan irrigation systems. For a candidate preparing for civil engineering examinations such as SSC JE, RRB JE and state AE exams, rainfall measurement is a highly scoring chapter, because questions on the types of rain gauges, the density of the gauge network, and the methods of computing average rainfall appear repeatedly in both theory and numerical form.

Rainfall is measured as the depth of water that accumulates on a horizontal surface, and it is expressed in millimetres or centimetres. A rain gauge essentially collects the rain falling on a known area into a container, and the depth is obtained by dividing the volume of water collected by the area of the collector. The standard Indian rain gauge, the Symons gauge, has a collector of diameter 127 mm (5 inches) and a measuring glass calibrated to directly give the rainfall in millimetres. In addition to non-recording gauges that give only the total rainfall over a period, recording gauges are used to obtain the variation of rainfall intensity with time, which is essential for the design of storm water systems.

In this chapter we will study the construction and working of the non-recording Symons rain gauge, the recording gauges of the tipping bucket, weighing and float types, the density of the rain gauge network recommended by the Indian Meteorological Department, and the three standard methods of estimating the areal average rainfall over a catchment, namely the arithmetic mean method, the Thiessen polygon method and the isohyetal method. We will also solve numerical examples on each of these methods, because numerical questions on the estimation of average rainfall are among the most frequently asked problems in hydrology.

2. Types of Rain Gauges

Rain gauges are broadly divided into non-recording gauges and recording gauges. The non-recording gauge, of which the Symons gauge is the standard type, consists of a circular collector funnel of 127 mm diameter fixed over a cylindrical container. The rain collected in the container is measured at fixed intervals, usually daily at 8:30 in the morning, by pouring the collected water into a measuring glass that is calibrated in millimetres of rainfall. Because the collector area is larger than the area of the measuring glass, the measuring glass is graduated such that one division on the glass represents a small depth of actual rainfall, typically 0.1 mm. The gauge is fixed with the rim of the funnel about 30 cm above the ground to prevent the splashing of rain water from the ground into the gauge.

The recording rain gauges are of three main types. The tipping bucket rain gauge consists of a collector funnel that directs water into a small two-compartment bucket pivoted at the centre; when one compartment receives a fixed volume, typically corresponding to 0.25 mm of rainfall, it tips and empties, and the other compartment moves into position, each tip being recorded electrically or mechanically. The tipping bucket gauge records the number of tips in each time interval and is therefore ideal for measuring rainfall intensity. The weighing type rain gauge collects the rain in a container mounted on a spring balance or weighing mechanism, and the increasing weight is recorded continuously on a chart, giving the total accumulated rainfall with time. The float type rain gauge uses a float that rises as water collects in the chamber, and the movement of the float operates a pen that traces the cumulative rainfall on a chart.

Each type of gauge has advantages and limitations. The Symons gauge is simple, cheap and accurate for daily totals, but it gives no information about intensity. The tipping bucket gauge is excellent for intensity measurement and for telemetry, but its accuracy is slightly affected during very heavy rain when some water may splash out during tipping. The weighing gauge gives a continuous record of accumulation and can also measure snow by melting it, while the float gauge must be provided with a siphon to empty the chamber automatically when it is full. The choice of gauge depends on the purpose: climatological stations use non-recording gauges for daily data, while engineering design uses recording gauges to obtain the intensity-duration relationships.

3. Network Density and Data Quality

The rainfall measured by a single gauge represents only a point value, and a single gauge can rarely represent the rainfall over a large catchment because rainfall varies appreciably in space. A network of gauges is therefore installed over the catchment, and the density of the network depends on the purpose of the measurements, the type of catchment and the climate. The Indian Meteorological Department recommends that for flat regions of the plains there should be one gauge for every 1300 square kilometres, for average elevations of 1000 metres one gauge for every 390 square kilometres, and for hilly regions of average elevation above 1000 metres one gauge for every 130 square kilometres, with at least three gauges in any catchment.

The quality of the rainfall record is as important as the density of the network. A gauge must be sited in an open place away from tall buildings and trees, and the rainfall record must be checked for errors and missing data. Missing data can be estimated by the station average method, the normal ratio method or the isohyetal method. In the normal ratio method, the missing rainfall at a station is estimated by taking the ratio of its long-term normal annual rainfall to the normal of the neighbouring stations and multiplying by their observed rainfall. This method is used when the normal annual rainfall at the station differs from that of its neighbours by more than 10 percent.

Example: The normal annual rainfall at stations X, Y and Z is 900 mm, 1200 mm and 1100 mm respectively. The rainfall recorded at Y and Z in a particular year is 90 cm and 80 cm respectively, while the record at X is missing. Estimate the missing rainfall at X by the normal ratio method.

Solution: By the normal ratio method, the missing rainfall Px at station X is given by Px = (Nx/3) x (Py/Ny + Pz/Nz), where Nx, Ny, Nz are the normal annual rainfalls and Py, Pz are the observed values. Substituting, Px = (900/3) x (90/1200 + 80/1100) = 300 x (0.075 + 0.072727) = 300 x 0.147727 = 44.32 cm. The missing rainfall at station X is therefore about 44.3 cm.

4. Methods of Estimating Areal Average Rainfall

When rainfall has been measured at several gauges in and around a catchment, the average depth of rainfall over the catchment must be computed for use in runoff and flood estimation. Three standard methods are used. The arithmetic mean method simply averages the rainfall recorded at all the gauges inside the catchment, assuming that the rainfall is uniformly distributed; it is the simplest method and is suitable when the gauges are uniformly spaced and the rainfall variation is small. The Thiessen polygon method assigns a weight to each gauge proportional to the area it represents, the polygons being constructed by drawing perpendicular bisectors of the lines joining adjacent gauges, and the weighted average is computed.

The isohyetal method is the most accurate method, and it uses contours of equal rainfall called isohyets drawn on the catchment map. The average rainfall is computed by multiplying the area between successive isohyets by the mean rainfall between them, summing these products, and dividing by the total catchment area. The isohyetal method is preferred when the catchment has irregular terrain and the gauges are not uniformly distributed, because it takes the areal variation of rainfall into account most realistically.

Example: A catchment has an area of 200 square kilometres. The rainfall at gauges located within the catchment is 80 mm, 95 mm, 90 mm and 100 mm. Compute the areal average rainfall by the arithmetic mean method.

Solution: Arithmetic mean = (80 + 95 + 90 + 100)/4 = 365/4 = 91.25 mm. The areal average rainfall by the arithmetic mean method is 91.25 mm.

Example: A catchment is divided by Thiessen polygons into four areas of 40, 60, 50 and 50 square kilometres, with rainfall at the corresponding stations of 80 mm, 95 mm, 90 mm and 100 mm. Compute the average rainfall by the Thiessen method.

Solution: Weighted average = sum of (area x rainfall)/total area = (40 x 80 + 60 x 95 + 50 x 90 + 50 x 100)/200 = (3200 + 5700 + 4500 + 5000)/200 = 18400/200 = 92.0 mm. The areal average rainfall by the Thiessen method is 92.0 mm.

5. Quick Revision Tables

Table 1: Types of Rain Gauges

Gauge type Recording Principle Main use
Symons gauge Non-recording Collect and measure by glass Daily rainfall totals
Tipping bucket Recording Bucket tips at fixed volume Rainfall intensity
Weighing type Recording Weight of water recorded Continuous accumulation, snow
Float type Recording Float movement drives pen Cumulative rainfall chart

Table 2: Methods of Average Rainfall Computation

Method Principle Weight Accuracy Use
Arithmetic mean Average of all station values Equal weight Low Uniform rain, uniform gauge spacing
Thiessen polygon Area-weighted average Proportional to polygon area Medium Non-uniform gauge distribution
Isohyetal Contours of equal rainfall Area between isohyets High Irregular terrain, most accurate

6. Mind Map

flowchart TD
    A[Rainfall Measurement] --> B[Rain gauges]
    A --> C[Network density]
    A --> D[Data quality]
    A --> E[Areal average methods]
    B --> B1[Symons non-recording]
    B --> B2[Tipping bucket]
    B --> B3[Weighing type]
    B --> B4[Float type]
    C --> C1[Plains 1300 sq km per gauge]
    C --> C2[Hills 130 sq km per gauge]
    D --> D1[Station average method]
    D --> D2[Normal ratio method]
    E --> E1[Arithmetic mean]
    E --> E2[Thiessen polygon]
    E --> E3[Isohyetal - most accurate]

7. Important Diagrams (SVG)

The following diagrams show the working of a tipping bucket rain gauge and the Thiessen polygon construction.

Tipping Bucket Rain Gauge Collector funnel Pivot Counter / drain Counter / recorder Each tip represents a fixed volume of rainfall. The number of tips is recorded with time. Golden Rule Tipping bucket gauge is used to measure rainfall intensity, not just the total depth.

Thiessen Polygon Construction A B C D E Average = Sum of (station rainfall x polygon area) / Total area Golden Rule Thiessen method weights each gauge by its polygon area.

8. Common Mistakes

  1. Many students state the diameter of the Symons gauge collector as 127 mm; some wrongly give 50 mm or 200 mm, but the standard is 127 mm.
  2. A frequent error is to think the Symons gauge records intensity; it gives only the total depth over a fixed interval.
  3. Some candidates confuse the weighing gauge with the float gauge; the weighing gauge records by weight, while the float gauge records by the rise of a float.
  4. Students often forget the site requirement that the gauge rim should be about 30 cm above the ground to avoid splashing.
  5. In the Thiessen method, students sometimes take a simple average instead of the area-weighted average; each gauge must be weighted by its polygon area.
  6. A common mistake is to say the arithmetic mean method is the most accurate; the isohyetal method is the most accurate of the three.
  7. When estimating missing data, students use the station average method when the normal rainfalls differ by more than 10 percent; in that case the normal ratio method must be used.
  8. Many candidates forget that at least three gauges should be present in any catchment, as recommended by the IMD.

9. Exam Tips

  1. Memorise the network densities: 1300 sq km per gauge for plains, 390 sq km for elevations of 1000 m, and 130 sq km for hilly regions above 1000 m.
  2. Remember that the standard daily reading time of the rain gauge is 8:30 in the morning.
  3. Learn that 0.25 mm of rainfall corresponds to one tip of the tipping bucket gauge, a figure that appears frequently.
  4. Practise at least one numerical on the arithmetic mean and one on the Thiessen polygon method with area weights.
  5. Know that the normal ratio method is used when the normal annual rainfall differs by more than 10 percent between the station and its neighbours.
  6. Remember the order of accuracy: isohyetal is most accurate, then Thiessen, then arithmetic mean.
  7. Note that the float gauge is provided with a siphon to empty the chamber automatically.
  8. Link the isohyetal method to flood estimation, since the areal average rainfall is the input to runoff calculations.

10. Conclusion

The measurement of rainfall is the starting point of all hydrologic analysis, because the reliability of every subsequent estimate, whether of runoff, flood or reservoir yield, depends on the quality of the rainfall data. In this chapter we have studied the construction and working of the non-recording Symons gauge and the recording tipping bucket, weighing and float gauges, the recommended density of the rain gauge network for different terrains, the methods of estimating missing rainfall data, and the three standard methods of computing the areal average rainfall over a catchment, namely the arithmetic mean, the Thiessen polygon and the isohyetal methods, with worked numerical examples. The candidate should remember the gauge dimensions, the network densities and the accuracy hierarchy of the averaging methods as the key revision points. Because the estimation of average rainfall is the direct input to the runoff and flood calculations of the later chapters, mastery of this chapter is essential for solving the numerical problems of the whole hydrology paper with confidence.