🏗️ Civil Engineering

13.6 Runoff and Factors Affecting Runoff

Start MCQ Practice →

13.6 Runoff and Factors Affecting Runoff

Subject: Civil Engineering Chapter: Hydrology Topic: 13.6 Runoff and Factors Affecting Runoff

1. Introduction

Runoff is the portion of the precipitation that appears in surface streams, rivers and channels and eventually drains out of a catchment, and it is the water that is actually available for use in reservoirs, canals, irrigation and water supply. Of all the water that falls as rain, a large part is lost by evaporation, transpiration and infiltration, and only the remainder appears as runoff. The quantitative estimation of runoff is therefore the central problem of hydrology, because the design of dams, spillways, culverts, bridges and drainage systems all begin with an estimate of the runoff that the catchment will deliver. For a candidate preparing for civil engineering examinations such as SSC JE, RRB JE and state AE exams, runoff is a high-yield chapter, and questions on the components of runoff, the factors affecting runoff, the rational formula and the curve number method appear year after year.

The runoff from a catchment can be divided into several components according to the path it follows. Surface runoff is the water that flows over the land surface to the streams without entering the soil, and it appears quickly after rainfall. Subsurface flow or interflow is the water that infiltrates the soil but moves laterally through the upper soil layers and reappears at the surface before reaching the streams. Groundwater flow or base flow is the water that percolates deeply into the ground and slowly discharges into the streams from the groundwater zone, sustaining the flow of rivers during dry periods. The total runoff at any time is the sum of these components, and the separation of the components from the stream flow record is an important practical operation.

In this chapter we will study the components and types of runoff, the climatic, physiographic and geologic factors that affect the amount of runoff, the concept of the runoff coefficient, the rational formula for peak runoff estimation from small catchments, the Soil Conservation Service curve number method, and the computation of runoff from rainfall using the runoff coefficient. We will also solve numerical problems on the rational formula and the curve number method, since these are standard examination questions.

2. Factors Affecting Runoff

The amount and rate of runoff from a catchment depend on climatic factors, physiographic factors and the land use of the catchment. Among the climatic factors, the most important is the intensity and duration of rainfall: a short intense storm produces more runoff than a long gentle rain because the intensity exceeds the infiltration capacity, while the duration determines how long the soil remains saturated and how much of the soil storage is exhausted. The antecedent moisture condition of the soil is equally important, because a soil that is already wet from previous rain will produce more runoff than a dry soil for the same amount of rainfall. The direction of storm movement also matters, since a storm moving in the direction of flow produces a higher and earlier peak than a storm moving against the direction of flow.

Among the physiographic factors, the size, shape and slope of the catchment are the most significant. A small catchment responds quickly to rainfall and produces a high peak runoff, while a large catchment responds slowly and produces a lower, broader peak. A fan-shaped catchment concentrates the runoff from all parts at the outlet simultaneously and produces a high peak, whereas an elongated catchment spreads the runoff over time and reduces the peak. Steeper slopes produce faster runoff and higher peaks, while flat catchments store water on the surface and reduce the peak. The soil type and geology control the infiltration and the groundwater contribution, and the vegetation cover reduces runoff by intercepting rainfall and increasing infiltration.

The land use of the catchment is a factor that is very much under human control. Forests and grasslands reduce runoff and moderate the peaks, while deforestation, overgrazing and urbanisation increase the runoff and make the peaks sharper and higher. Urbanisation replaces the pervious natural surface with impervious roofs, roads and pavements, which both reduces infiltration and shortens the time of concentration, so that the same rainfall produces a much higher flood peak in an urban catchment than in a rural catchment. This is why hydrologists insist that the land use of a catchment must be carefully considered while estimating the design flood.

3. Rational Formula and Runoff Coefficient

For small catchments, the peak runoff can be estimated by the rational formula, which is the oldest and simplest method of runoff estimation. The rational formula is Q = C I A, where Q is the peak runoff rate in cubic metres per second, C is the dimensionless runoff coefficient, I is the average rainfall intensity corresponding to the time of concentration of the catchment, in millimetres per hour, and A is the catchment area in hectares, with a unit conversion factor of 1/360. The rational formula assumes that the peak runoff occurs when the entire catchment is contributing to the runoff at the outlet, which happens when the rainfall duration equals the time of concentration, and it is valid for small catchments of area less than about 50 square kilometres.

The runoff coefficient C is the ratio of the runoff to the rainfall, and it depends on the soil, the land use, the slope and the antecedent moisture. The coefficient is high for impervious surfaces and low for pervious, vegetated land: for paved areas it may be 0.7 to 0.95, for bare earth about 0.2 to 0.4, for forest land about 0.1 to 0.3, and for flat agricultural land about 0.1 to 0.2. When a catchment contains different surfaces, a weighted runoff coefficient is computed from the area of each surface. The rational formula is widely used in the design of storm water drains and culverts, and it must be remembered with its unit conversions.

Example: A small urban catchment of area 20 hectares has a weighted runoff coefficient of 0.6. If the rainfall intensity corresponding to the time of concentration is 40 mm/h, determine the peak runoff by the rational formula.

Solution: Q = C I A/360 = 0.6 x 40 x 20/360 = 480/360 = 1.333 cubic metres per second. The peak runoff is about 1.33 cubic metres per second. If the area were given in square kilometres instead of hectares, the same formula with A in hectares gives the result directly in cubic metres per second.

4. Curve Number Method and Runoff Computation

The Soil Conservation Service (SCS) curve number method is a more advanced method for estimating runoff from small and medium catchments, and it is based on the relation between the rainfall, the runoff, the soil type, the land use and the antecedent moisture condition. The runoff depth is computed by the formula Q = (P - 0.2S)^2/(P + 0.8S) when P is greater than 0.2S, and zero otherwise, where Q is the runoff in millimetres, P is the rainfall in millimetres, and S is the potential maximum retention given by S = 25400/CN - 254, with CN being the curve number. The curve number ranges from 0 to 100, with higher values indicating greater runoff potential, and it depends on the hydrologic soil group, the land use, the treatment and the antecedent moisture condition.

The curve number method is used widely in the design of small watershed structures, storm water management and flood estimation, because it takes the soil and land use characteristics of the catchment into account through the single parameter CN. The hydrologic soil groups range from group A soils, which have high infiltration and low runoff, to group D soils, which have very low infiltration and high runoff. For average antecedent moisture conditions (AMC II), the curve number is obtained from standard tables, and it is adjusted by the tables for dry (AMC I) and wet (AMC III) conditions.

Example: A catchment has a curve number CN of 80 for average antecedent conditions. If the storm rainfall is 150 mm, determine the direct runoff by the SCS method.

Solution: First compute S = 25400/CN - 254 = 25400/80 - 254 = 317.5 - 254 = 63.5 mm. Since P = 150 mm is greater than 0.2S = 12.7 mm, the runoff is Q = (P - 0.2S)^2/(P + 0.8S) = (150 - 12.7)^2/(150 + 50.8) = (137.3)^2/200.8 = 18851.29/200.8 = 93.88 mm. The direct runoff is about 93.9 mm, or about 63 percent of the rainfall.

5. Quick Revision Tables

Table 1: Components and Types of Runoff

Component Path of flow Time of arrival Contribution
Surface runoff Over land to streams Immediate after rain Peak of the hydrograph
Interflow / subsurface flow Lateral through soil Delayed Rising and falling limbs
Groundwater flow / base flow Deep percolation to streams Very slow, continuous Low flow of rivers
Direct runoff Surface + interflow Short Storm hydrograph peak
Total runoff All components Continuous Annual yield of catchment

Table 2: Runoff Coefficients for the Rational Formula

Surface type Runoff coefficient C
Paved roads and roofs 0.70 to 0.95
Bare earth 0.20 to 0.40
Forest land 0.10 to 0.30
Agricultural land 0.10 to 0.20
Flat cultivated land 0.10 to 0.20
Hilly steep slopes 0.50 to 0.60

6. Mind Map

flowchart TD
    A[Runoff] --> B[Components]
    A --> C[Factors affecting]
    A --> D[Estimation methods]
    A --> E[Runoff coefficient]
    B --> B1[Surface runoff]
    B --> B2[Interflow]
    B --> B3[Base flow]
    C --> C1[Rainfall intensity and duration]
    C --> C2[Antecedent moisture]
    C --> C3[Shape, slope, size of catchment]
    C --> C4[Land use and urbanisation]
    D --> D1[Rational formula Q = CIA/360]
    D --> D2[SCS curve number method]
    D --> D3[Infiltration index method]
    E --> E1[Ratio of runoff to rainfall]
    E --> E2[High for paved, low for forest]

7. Important Diagrams (SVG)

The following diagrams show the components of runoff and the effect of catchment shape on the runoff hydrograph.

Components of Runoff RAINFALL Surface runoff Fastest component Interflow Lateral soil flow Groundwater flow Base flow, slowest Total runoff in the stream Direct runoff + base flow Base flow sustains river flow during dry periods. Golden Rule Total runoff equals surface runoff plus interflow plus base flow.

Effect of Catchment Shape on Peak Runoff Fan-shaped (high peak) Elongated (low broad peak) Hydrographs for the same rainfall Fan shape - high sharp peak Elongated - low broad peak Golden Rule A fan-shaped catchment concentrates flow and produces a higher peak than an elongated one.

8. Common Mistakes

  1. Many students think that all rainfall becomes runoff; in reality a large part is lost by evapotranspiration and infiltration.
  2. A frequent error is to use the rational formula for large catchments; it is valid only for small catchments, generally less than 50 square kilometres.
  3. Some candidates forget the unit conversion in the rational formula and use Q = C I A without dividing by 360 when the area is in hectares and intensity in mm/h.
  4. Students often confuse base flow with surface runoff; base flow is the slow groundwater contribution, while surface runoff is the fast overland flow.
  5. It is wrong to say that urbanisation reduces the flood peak; urbanisation increases the peak because of impervious surfaces and a shorter time of concentration.
  6. A common mistake is to think that a wet soil produces less runoff than a dry soil; a wet soil produces more runoff because the infiltration is reduced.
  7. Many candidates state that the runoff coefficient of a forest is high; forest land has a low coefficient of about 0.1 to 0.3.
  8. Students frequently forget the antecedent moisture condition while using the curve number method; the CN must be adjusted for AMC I and AMC III.

9. Exam Tips

  1. Memorise the rational formula Q = C I A/360 with the units: Q in cubic metres per second, I in mm/h and A in hectares.
  2. Learn the runoff coefficient ranges for paved, bare, forest and agricultural surfaces, because direct questions on C are common.
  3. Remember the SCS formula Q = (P - 0.2S)^2/(P + 0.8S) and S = 25400/CN - 254, and practise one numerical.
  4. Know the three runoff components, surface runoff, interflow and base flow, with their times of arrival.
  5. Remember that antecedent moisture condition and storm movement affect runoff strongly; wet soils and storms moving downstream give higher peaks.
  6. Note that the rational formula is valid only when the rainfall duration equals or exceeds the time of concentration.
  7. Link the runoff coefficient to the land use: high for paved, low for vegetated land.
  8. Remember that the curve number ranges from 0 to 100 and that group A soils have low runoff.

10. Conclusion

Runoff is the usable water delivered by a catchment, and its estimation is the central problem of hydrology because all water resource structures are designed around it. In this chapter we have studied the components of runoff, including surface runoff, interflow and base flow, the climatic, physiographic and land use factors that affect the quantity and rate of runoff, the runoff coefficient, the rational formula for the estimation of peak runoff from small catchments, and the SCS curve number method for the estimation of runoff depth from rainfall, with worked numerical examples. The candidate should remember the rational formula with its unit conversion, the range of runoff coefficients, and the SCS method as the core revision points. Because the runoff estimated in this chapter is the input to the hydrograph and flood chapters, a clear understanding of the factors and the estimation methods presented here is essential for solving the numerical problems of the later chapters and for the correct design of drainage and flood control structures.