🏗️ Civil Engineering

Spillways and Energy Dissipation

Start MCQ Practice →

Spillways and Energy Dissipation

Subject: Civil Engineering Chapter: Irrigation Engineering Topic: 14.9 Spillways and Energy Dissipation

1. Introduction

A spillway is a structure provided on a dam to release surplus or flood water which cannot be safely stored in the reservoir, so that the water level never rises above the maximum designed level and the dam is never overtopped. It is often said that a spillway is the safety valve of a dam, because the failure of a spillway or its insufficiency has caused more dam failures than any other single cause. The discharge capacity of a spillway must be adequate to pass the design flood, and the excess energy of the water falling over the spillway must be dissipated harmlessly before the water returns to the river, otherwise the river bed below the dam will be scoured away. Energy dissipation structures such as stilling basins and hydraulic jump dissipators are therefore an integral part of the spillway design.

The design flood for a spillway is the maximum flood that the spillway is expected to pass safely, and it is estimated from the catchment characteristics and the probable maximum flood. The spillway must be able to pass this flood without allowing the reservoir level to exceed the maximum water level. The water flowing over a spillway acquires a very high velocity and a large amount of kinetic energy, and if this energy is not dissipated, the tail water will erode the river bed and endanger the dam. The energy is dissipated by converting the high velocity flow into a lower velocity flow through a hydraulic jump, which takes place in a structure called the stilling basin.

In this chapter we will study the types of spillways, the discharge formula for spillways, the concept of the hydraulic jump and its uses, the types of energy dissipators such as the stilling basin and the bucket, and the worked numerical problems on spillway discharge and hydraulic jump calculations.

2. Types of Spillways

Spillways are classified according to their layout and control features. The ogee or overflow spillway has a crest shaped to the profile of the underside of an overflowing nappe, so that the water flows smoothly over the crest with the least interference. The ogee spillway has a high discharge coefficient and is the most common type used on concrete dams. The free overfall spillway allows the water to fall freely over a vertical wall into the downstream channel, and it is used when the downstream water level is low. The side channel spillway collects the overflowing water in a channel running along the side of the spillway, and it is used in narrow valleys where space is limited. The shaft or morning glory spillway discharges the water over a circular rim into a vertical shaft and then through a horizontal tunnel, and it is useful where there is no space for a conventional overflow crest.

The siphon spillway is a closed conduit which, when filled with water, acts as a siphon and discharges water automatically once the reservoir level exceeds the crest. It has a large discharge capacity for a small width but requires careful priming. The chute or trough spillway carries the overflowing water down a steep, open channel to the downstream river, and it is used where the spillway is separate from the dam. The discharge over an ogee spillway is computed by the formula in which the discharge per metre length equals a coefficient multiplied by the effective head over the crest raised to the power 1.5, where the coefficient depends upon the shape of the crest and the head. For a standard ogee crest the coefficient is about 1.7 to 2.2 in SI units, and this formula is the basis of spillway sizing.

3. Hydraulic Jump and Energy Dissipation

When a fast, shallow stream of water flowing over a spillway meets a slow, deep stream, the flow changes suddenly from supercritical to subcritical through a phenomenon called the hydraulic jump. In a hydraulic jump the kinetic energy of the flow is destroyed by turbulence and converted into heat, so the jump is an excellent energy dissipator. The ratio of the depths before and after the jump depends upon the Froude number of the approaching flow, and a stronger jump is formed when the Froude number is higher. The sequent depths of the jump, that is the depth before and the depth after the jump, are related by the classical hydraulic jump equation, and the head lost in the jump is the difference between the energy before and the energy after.

The energy dissipation structures used below spillways include the stilling basin, which is a concrete basin constructed below the spillway in which the hydraulic jump is forced to form by providing a level apron, end sills and baffle blocks, and the roller bucket, which is a curved concrete bucket at the end of the spillway that turns the high velocity jet upwards and forwards so that a roller is formed and energy is dissipated by turbulence. The apron of a stilling basin is protected by a sheet of concrete and may be provided with baffle blocks and a solid end sill to increase the energy loss and to shorten the basin. The main factors governing the design of an energy dissipator are the head over the spillway, the discharge, the tail water depth and the Froude number of the incoming flow.

Worked example: Water flows at a depth of 0.6 m with a velocity of 8 m/s down the face of a spillway. Determine the Froude number and the type of jump, taking g as 9.81.

Solution: 1. Froude number F = V / square root of (g x d) = 8 / square root of (9.81 x 0.6) = 8 / 2.426 = 3.30. 2. Since the Froude number is between 1.7 and 4.5, a steady jump is formed which dissipates energy moderately. 3. Sequent depth using the jump equation d2 / d1 = 0.5 x (square root of (1 + 8 F squared) - 1) = 0.5 x (square root of (1 + 8 x 10.9) - 1) = 0.5 x (square root of 88.2 - 1) = 0.5 x (9.39 - 1) = 4.2, so d2 = 0.6 x 4.2 = 2.52 m.

4. Spillway Discharge and Worked Examples

The capacity of a spillway is determined by the discharge formula for the chosen type. For an ogee spillway the discharge per metre length is the product of the coefficient and the head raised to the power 1.5, and the total discharge is this value multiplied by the effective length of the crest. The effective length may be reduced by the presence of piers, which are the intermediate supports of the crest gates, and by the abutments at the ends. The crest gates control the water level by storing more water in the reservoir and passing the flood only when necessary.

Worked example: An ogee spillway has a crest length of 80 m and is designed for a head of 3 m over the crest. The discharge coefficient is 2.0. Determine the total discharge over the spillway.

Solution: 1. Discharge per metre length = C x H to the power 1.5 = 2.0 x 3 to the power 1.5 = 2.0 x 5.196 = 10.39 cumec per metre. 2. Total discharge = 10.39 x 80 = 831.4 cumec.

Worked example: A free overfall spillway carries a discharge of 200 cumec with a head of 2.5 m over a crest of 50 m length. Determine the discharge coefficient of the crest.

Solution: 1. Discharge per metre = 200 / 50 = 4 cumec per metre. 2. Using q = C x H to the power 1.5, C = q / H to the power 1.5 = 4 / (2.5 to the power 1.5) = 4 / 3.95 = 1.01. 3. This low coefficient indicates that the crest is not an efficient ogee profile.

5. Quick Revision Tables

Table 1: Types of Spillways

Type Feature Best use
Ogee Crest shaped to nappe Concrete gravity dams
Free overfall Water falls freely Low tail water levels
Side channel Channel alongside crest Narrow valleys
Shaft Circular rim, vertical shaft Confined sites
Siphon Self-priming closed conduit Limited width, high discharge

Table 2: Hydraulic Jump Classification

Froude number Type of jump Energy dissipation
Less than 1.7 Undular jump Very small
1.7 to 2.5 Weak jump About 18 percent
2.5 to 4.5 Oscillating/steady jump 45 to 70 percent
4.5 to 9.0 Steady jump 70 percent
Above 9.0 Strong jump About 85 percent

6. Mind Map

flowchart TD
    A[Spillways and Energy Dissipation] --> B[Purpose of spillway]
    A --> C[Types of spillways]
    A --> D[Discharge formula]
    A --> E[Hydraulic jump]
    A --> F[Energy dissipators]
    B --> B1[Pass surplus flood]
    B --> B2[Prevent overtopping]
    C --> C1[Ogee spillway]
    C --> C2[Free overfall]
    C --> C3[Side channel and shaft]
    C --> C4[Siphon and chute]
    D --> D1[q = C H^1.5]
    E --> E1[Supercritical to subcritical]
    E --> E2[Froude number]
    E --> E3[Sequent depths]
    F --> F1[Stilling basin]
    F --> F2[Roller bucket]
    F --> F3[Baffle blocks and end sill]

7. Important Diagrams (SVG)

The following diagrams show the ogee spillway profile and the hydraulic jump.

Ogee Spillway Profile H (head over crest) ogee crest follows nappe shape high velocity jet Discharge q = C H to the power 1.5 per metre length C is about 1.7 to 2.2 for a standard ogee crest Golden Rule Spillway discharge per metre varies as the head raised to the power 1.5.

Hydraulic Jump in a Stilling Basin supercritical shallow fast flow HYDRAULIC JUMP subcritical deep slow flow stilling basin apron The jump converts kinetic energy into turbulence and heat. Froude number decides the type and strength of the jump. Golden Rule The hydraulic jump is the most efficient energy dissipator below a spillway.

8. Common Mistakes

  1. Many students think a spillway is used to generate power; its real purpose is to pass surplus flood water safely.
  2. A frequent error is to use the square of the head instead of the head raised to the power 1.5 in the ogee spillway formula.
  3. Some candidates believe the hydraulic jump converts energy into useful work, but it actually dissipates energy by turbulence.
  4. Students often forget that the Froude number below 1.7 gives only a weak undular jump with poor energy dissipation.
  5. A common mistake is to design the stilling basin without considering the tail water depth, which controls the position of the jump.
  6. Many candidates think siphon spillways need priming every time, but they are self-priming once primed by rising water.
  7. Students often ignore the reduction in effective crest length caused by piers and abutments when computing spillway discharge.

9. Exam Tips

  1. Memorise the ogee spillway discharge formula q = C H to the power 1.5 and the typical coefficient range of 1.7 to 2.2.
  2. Remember that the spillway protects the dam from overtopping and is called the safety valve of the dam.
  3. Learn the Froude number classification of jumps and the energy dissipation percentages in each range.
  4. Note that a stilling basin forces the hydraulic jump to form within a controlled length using baffles and end sills.
  5. For numericals, remember Froude number = V divided by the square root of g times the depth.
  6. Remember that the shaft spillway is also called the morning glory spillway and the chute spillway is also called the trough spillway.
  7. Practise at least one discharge numerical and one hydraulic jump numerical before the exam.

10. Conclusion

Spillways and energy dissipation structures are the protective organs of a dam, ensuring that surplus flood water is released safely and that the destructive energy of the falling water does not erode the foundation of the dam. In this chapter we have studied the different types of spillways including the ogee, free overfall, side channel, shaft, siphon and chute spillways, the discharge formula q equals C H to the power 1.5, and the hydraulic jump which converts supercritical flow into subcritical flow while dissipating a large part of the kinetic energy. We have also studied the stilling basin and the roller bucket as energy dissipators, and the role of the Froude number in fixing the type and strength of the jump. The worked examples on spillway discharge and sequent depths provide the numerical practice required by examinations. Together with the dam, the spillway completes the storage works of an irrigation project, and understanding its behaviour is essential for the safe design and operation of reservoirs.

10.1 Additional Worked Examples

Worked example: An ogee spillway with a crest length of 60 m passes a flood of 900 cumec. If the coefficient is 2.1, determine the head over the crest.

Solution: 1. Discharge per metre = 900 / 60 = 15 cumec per metre. 2. q = C H to the power 1.5, so H to the power 1.5 = 15 / 2.1 = 7.143. 3. H = 7.143 to the power (2/3) = 3.71 m. The head over the crest is about 3.71 m.