Subject: Civil Engineering Chapter: Public Health Engineering Topic: 16.4 Sewer Appurtenances
Sewer appurtenances are the various accessory structures and devices that are built as an integral part of a sewerage system to make the sewer functional, accessible and easy to maintain. A sewer pipe alone cannot serve the public, because it must be inspected, cleaned, ventilated and connected to the houses, and it changes direction, gradient and size at many points. The structures that make all this possible are called appurtenances, and the most important among them are manholes, drop manholes, street inlets, catch basins, flushing devices, ventilation shafts, inverted siphons and storm water regulators.
The study of sewer appurtenances is a very scoring topic for competitive examinations, because each appurtenance has a definite purpose, a definite location and a definite set of dimensions, and questions on these points are direct and factual. For example, a manhole is required wherever the sewer changes direction, gradient or size, and at every junction and at regular intervals along a straight run, and the examiner often asks for the maximum spacing of manholes or the size of the chamber. Similarly, the drop manhole is used where a side sewer joins a main sewer at a greater depth, and the catch basin is used to remove grit and sand from storm water.
In this chapter we will study each important appurtenance in detail, including its purpose, construction, location and the numerical rules associated with it, such as the spacing of manholes and the depth of a drop manhole. Numerical examples on the computation of manhole spacing and on the sizing of a flushing device are also included, because such problems are often set in the examination.
A manhole is a masonry or concrete chamber constructed at intervals along a sewer so that a workman can enter the sewer for inspection, cleaning and repairs. Manholes are provided at every point where the sewer changes direction, where its gradient changes, where two or more sewers meet, where the diameter of the sewer changes, and at regular intervals along straight runs. The cover of a manhole is generally made of cast iron and is placed flush with the road surface, and the steps or ladders are fixed inside the chamber to allow a workman to climb down.
The spacing of manholes depends on the size of the sewer and the ease of cleaning. For a small sewer of 300 mm diameter, manholes are spaced at about 30 to 45 metres, while for larger sewers of 900 mm diameter or more, the spacing is increased to about 90 to 150 metres, because a larger sewer can be cleaned from a greater distance with a rodding or flushing machine. A general rule is that manholes are spaced so that no point in the sewer is more than about 100 m from a manhole for small sewers. When the sewer changes size, an invert drop is provided, and when the difference in the levels of the branch and the main sewer is more than about 0.6 m, a drop manhole is constructed.
A drop manhole is a manhole in which the branch sewer is brought above the level of the main sewer and the sewage is allowed to fall vertically into the main sewer through a vertical pipe, so that the energy of the falling sewage is dissipated and the flow is not disturbed. The drop is generally not more than 1 m, and the vertical pipe is often provided with a curved bend at its lower end to reduce the velocity of fall. Drop manholes are necessary when a lateral sewer joins a deep main sewer, because without the drop the sewage would erode the invert of the main sewer.
Street inlets are the openings provided at the side of the road through which the storm water from the road surface enters the storm water sewer or combined sewer. They are generally constructed at the lowest point of the road, near the kerb, and at regular intervals so that water does not accumulate on the road. The common types are the curbside inlet, which is an opening in the vertical kerb, and the grated inlet, which is a horizontal opening covered with a grating in the road surface. Street inlets are usually connected to the sewer through a small trap to prevent the entry of foul gases from the sewer into the street.
A catch basin is a small chamber provided below a street inlet to trap the grit, sand and heavy debris that would otherwise enter the sewer and settle in it. The storm water enters the catch basin through the inlet, the heavy particles settle to the bottom of the basin, and the comparatively clean water passes out through an outlet pipe which is placed above the bottom of the basin. The settled grit is removed periodically. Catch basins are especially useful where the storm water carries a large amount of sand, such as in the roads of sandy regions, although they are sometimes omitted because they become a source of odour and mosquitoes if not cleaned regularly.
Flushing devices are the appurtenances used to clean a sewer that does not carry enough flow to develop the self-cleansing velocity. The simplest flushing device is a dam board, which is a wooden board that can be placed across the sewer near a manhole to store the sewage, and when the board is removed the stored sewage rushes down the sewer and flushes away the deposits. Automatic flushing tanks are also used at the head of sewers that carry little flow; the tank fills with sewage, and when the water reaches a certain level a syphon starts discharging the whole tankful suddenly, creating a wave that cleans the sewer.
An inverted siphon, also called a depressed sewer, is used where a sewer has to pass under an obstruction such as a river, a railway track or a deep depression. In a normal sewer the flow is by gravity from a higher level to a lower level, but at an inverted siphon the sewer is carried below the obstruction and then rises again, so that the sewer is full and flows under pressure at that point. Because solids tend to settle in a depressed sewer, an inverted siphon is generally constructed with two or more pipes: a small pipe for the dry weather flow, a medium pipe for the average flow and a large pipe for the peak flow, each having a self-cleansing velocity.
The velocity in an inverted siphon must be kept above the self-cleansing value even at the minimum flow, which is why the dry weather flow is carried in a small pipe of about 150 to 200 mm diameter. The inlet chamber of an inverted siphon is provided with side weirs and a penstock or gate, so that the flow can be divided among the pipes according to the rate of discharge. The outlet chamber returns the flow from the pipes into the sewer. Inverted siphons are expensive and difficult to clean, so they are avoided wherever a gravity sewer can be laid, but they are unavoidable at river and railway crossings.
Storm water regulators are the devices used in a combined system to divert the excess storm water from the combined sewer into a storm water drain or stream during heavy rains, so that the treatment plant is not overloaded. The simplest regulator is a side overflow weir, over which the diluted sewage spills when the flow in the combined sewer exceeds a certain limit. The diluted sewage that spills is called the storm sewage, and although it is not fully treated, it is diluted to a degree considered safe for the receiving stream. Regulators must be placed so that the first foul flush of the storm, which contains the heaviest pollution, is not diverted but is carried to the treatment plant.
Problem: A 450 mm diameter sewer is to be provided with manholes. If the maximum spacing of manholes for a 450 mm sewer is taken as 60 m and the sewer is 720 m long, find the number of manholes required including the manhole at the upstream end.
Solution: Spacing = 60 m. Length = 720 m. Number of spacings = 720/60 = 12. The number of manholes is one more than the number of spacings when both ends have manholes, so number of manholes = 12 + 1 = 13.
Answer: Thirteen manholes are required along the sewer.
Problem: An inverted siphon is to carry a dry weather flow of 0.01 cubic metres per second and a peak flow of 0.05 cubic metres per second. If the small pipe is designed for the dry weather flow at a velocity of 1.0 m/s, find the diameter of the small pipe.
Solution: Required area of the small pipe A = Q/V = 0.01/1.0 = 0.01 square metres. Diameter D = sqrt(4A/pi) = sqrt(4 x 0.01/3.1416) = sqrt(0.01273) = 0.1128 m.
Answer: The diameter of the small pipe is about 0.11 m, so a 150 mm nominal pipe is adopted.
| Sewer diameter | Maximum spacing |
|---|---|
| 300 mm | 30 to 45 m |
| 450 mm | 60 m |
| 600 mm | 75 to 90 m |
| 900 mm and above | 90 to 150 m |
| Appurtenance | Function | Location |
|---|---|---|
| Manhole | Inspection, cleaning and ventilation | Direction, gradient, size changes |
| Drop manhole | Connect branch at higher level to deep main | Difference more than 0.6 m |
| Street inlet | Admit storm water from road | Kerb or low points of road |
| Catch basin | Trap grit and sand | Below street inlets |
| Inverted siphon | Pass sewer below obstruction | River, railway crossings |
| Flushing device | Clean sewer by stored water | Head of flat sewers |
flowchart TD
A[Sewer Appurtenances] --> B[Manholes]
A --> C[Drop manholes]
A --> D[Street inlets]
A --> E[Catch basins]
A --> F[Flushing devices]
A --> G[Inverted siphon]
A --> H[Storm water regulators]
B --> B1[Spacing 30 to 150 m]
B --> B2[Cast iron cover]
C --> C1[For drop more than 0.6 m]
C --> C2[Vertical pipe dissipates energy]
D --> D1[Curbside and grated inlets]
E --> E1[Traps grit and sand]
F --> F1[Dam board and flushing tank]
G --> G1[Two or three pipes]
G --> G2[Small pipe for dry weather flow]
H --> H1[Side overflow weir]
The following diagrams show a typical manhole section and a drop manhole with its vertical drop pipe.
Sewer appurtenances convert a mere collection of pipes into a usable and maintainable sewerage system, because without manholes the sewer cannot be cleaned, without inlets the storm water cannot enter, and without siphons and regulators the sewer cannot cross obstacles or protect the treatment plant. In this chapter we have studied the manhole and the drop manhole, the street inlet and the catch basin, the flushing devices, the inverted siphon and the storm water regulator, together with their purposes, locations and the numerical rules of spacing and dimensioning. The numerical examples on manhole spacing and siphon pipe sizing have shown how these rules are applied in practice. A candidate who knows the function of each appurtenance and the standard spacings and depths quoted in this chapter will be able to answer the factual questions of this topic quickly and confidently, because the whole topic is based on memorised definitions and values rather than lengthy computation.