Subject: Civil Engineering Chapter: Reinforced Cement Concrete Topic: 9.2 Limit State Design
The limit state method is the modern and recommended philosophy of structural design for reinforced concrete as per IS 456:2000. In this approach the structure is designed to ensure that it remains fit for use throughout its intended life under all expected conditions of loading and environment. The word limit state refers to a condition of the structure at which it just ceases to satisfy the requirements for which it was designed. A structure is considered safe and serviceable only when the probability of reaching any limit state during its design life is acceptably small. For a candidate preparing for civil engineering competitive examinations, the limit state method is the single most important design philosophy, because the entire analysis of beams, slabs, columns and footings in the syllabus is carried out using this method.
The limit state method replaces the old single factor of safety of the working stress method with a set of partial safety factors. These factors are applied separately to the characteristic loads and to the characteristic strengths of the materials, recognising that loads may exceed their expected values and that material strengths may fall below their specified values. The resulting design is both safer and more economical than the working stress method, because the actual probability distribution of loads and strengths is considered rather than one blanket safety factor. This probabilistic basis is what makes the limit state design more rational and is frequently tested in examinations through conceptual questions on partial safety factors.
The limit state method divides all possible failure conditions into two broad categories: the limit state of collapse and the limit state of serviceability. The limit state of collapse includes flexure, shear, torsion, compression and buckling, and it safeguards the structure against loss of life and property. The limit state of serviceability includes deflection, cracking and vibration, and it ensures that the structure remains comfortable and pleasant to use. In this chapter we will study the two categories of limit states in detail, the partial safety factors for loads and materials, the design load and design strength concepts, and the stress-strain curves for concrete and steel used in limit state analysis.
The limit state of collapse is concerned with the safety of the structure and its occupants. Under the action of design loads, the structure must possess adequate strength to resist bending, shear, torsion and axial forces without collapse. The limit state of collapse includes the ultimate limit state in flexure, where the section fails by crushing of concrete or yielding of steel; the limit state in shear, where diagonal tension cracks develop; the limit state in torsion; and the limit state of buckling or instability, which is particularly important for slender columns. When the structure reaches the limit state of collapse, it is on the verge of failure, and the design ensures that this state is never reached under the working loads of the structure.
The limit state of serviceability is concerned with the day-to-day performance of the structure. Even if a structure is strong enough to avoid collapse, it can still be unusable if it deflects excessively, cracks widely or vibrates uncomfortably. The limit state of serviceability therefore imposes limits on deflection and crack width under working loads. For example, the maximum deflection of a flexural member is limited to span divided by 250 when the member supports partitions or brittle finishes, and to span divided by 350 for continuous spans. Crack width is limited so that the reinforcement does not corrode and the appearance of the structure is not damaged. These serviceability checks ensure that the structure remains functional throughout its life.
The two categories are not independent; a structure designed for the limit state of collapse may still fail serviceability requirements, and vice versa. For instance, a very deep beam may be perfectly safe in flexure but may deflect beyond the permissible limit, requiring an increase in depth. Similarly, a thin slab may satisfy deflection limits but crack excessively under temperature changes. The designer must therefore check both categories. In the limit state method, the design is first carried out for the limit state of collapse, and then the serviceability requirements of deflection and cracking are verified. This two-stage procedure is a hallmark of limit state design and is often examined through descriptive questions.
The characteristic load is the load which has a 95 percent probability of not being exceeded during the life of the structure, and the characteristic strength is the strength below which not more than 5 percent of test results are expected to fall. These characteristic values represent the statistically defined nominal values of loads and strengths. Since a structure must be safe even when the actual load exceeds the characteristic value and the actual strength falls below the characteristic value, the design uses factored values obtained by multiplying or dividing by partial safety factors.
The design load is obtained by multiplying the characteristic load by the partial safety factor for loads, which is denoted gamma f. For the limit state of collapse, the partial safety factor for loads is 1.5 for dead load, live load and all their combinations. For the limit state of serviceability, the partial safety factor for loads is taken as 1.0, because under working conditions the loads are expected to be at their characteristic values. The design strength is obtained by dividing the characteristic strength by the partial safety factor for material. For concrete, the partial safety factor is 1.5, giving a design strength of 0.67 fck for flexural compression; for steel, the partial safety factor is 1.15.
The application of these partial safety factors produces the factored design values used in all limit state calculations. For example, if a beam carries a characteristic dead load of 30 kN/m and a characteristic live load of 20 kN/m, the design load is 1.5 times (30 plus 20), which equals 75 kN/m. This design load is then used to compute the design bending moment and design shear force. The design bending moment is compared with the design moment of resistance of the section, which is computed using the design strengths of concrete and steel. This clear separation of load factors from material factors is the essence of the limit state philosophy and is a frequent source of numerical questions.
The limit state method uses idealised stress-strain curves for the two materials. For concrete, the stress-strain curve in compression is parabolic up to a strain of 0.002, and thereafter it is horizontal at a constant stress of 0.67 fck (the design strength) up to the ultimate strain of 0.0035. For the analysis of a section, this curve is simplified into a rectangular stress block of depth 0.8 times the neutral axis depth, as per the assumptions of the code. The total compressive force in the concrete is then equal to 0.36 fck multiplied by the width of the section and the depth of the neutral axis, and its line of action is located at 0.42 times the neutral axis depth from the top compression fibre.
For steel, the stress-strain curve is taken as a bilinear diagram. Steel behaves elastically up to its yield stress, and then it yields at a constant stress without further increase, up to the maximum design strain of 0.87 fy divided by Es, that is, 0.002 plus 0.87 fy divided by 200000. Since steel may be in tension or compression, the design stress in steel is 0.87 fy in both cases. These simplified stress-strain relationships allow the engineer to compute the moment of resistance of a section quickly, because the forces in the concrete and steel are obtained directly from the design stresses and the geometry of the section.
The design assumptions of the limit state method are fourfold. First, plane sections remain plane before and after bending, which means that strain varies linearly across the depth of the section. Second, the maximum strain in concrete at the outermost compression fibre is taken as 0.0035. Third, the tensile strength of concrete is ignored, and all tension is assumed to be carried by the reinforcement. Fourth, the stresses in the reinforcement are derived from the stress-strain curve, with the maximum stress limited to 0.87 fy. These assumptions, combined with the concept of strain compatibility, allow the computation of the neutral axis depth and the moment of resistance for any reinforced concrete section.
| Quantity | Partial Safety Factor | Application |
|---|---|---|
| Dead and live load (collapse) | 1.5 | Multiply characteristic load |
| Loads (serviceability) | 1.0 | Working load condition |
| Concrete | 1.5 | Divide characteristic strength fck |
| Steel | 1.15 | Divide characteristic strength fy |
| Design compressive stress in concrete | 0.67 fck | Flexural compression |
| Limit State | Type | Example Checks |
|---|---|---|
| Collapse | Safety against failure | Flexure, shear, torsion, compression, buckling |
| Serviceability | Performance under working loads | Deflection limited to span/250, crack width |
| Serviceability | Comfort of users | Vibration control, appearance |
| Collapse | Stability | Overturning, sliding, buckling of slender columns |
flowchart TD
A[Limit State Design] --> B[Limit state of collapse]
A --> C[Limit state of serviceability]
A --> D[Partial safety factors]
A --> E[Stress-strain curves]
B --> B1[Flexure, shear, torsion]
B --> B2[Compression, buckling]
C --> C1[Deflection limit span/250]
C --> C2[Crack width control]
D --> D1[Load factor 1.5]
D --> D2[Concrete 1.5, Steel 1.15]
E --> E1[Concrete parabolic up to 0.002 then constant]
E --> E2[Rectangular stress block 0.8 Xu]
E --> E3[Steel bilinear up to 0.87 fy]
E --> E4[Max strain concrete 0.0035]
The following diagrams show the design stress-strain curves and the rectangular stress block used in limit state analysis.
The limit state method is the backbone of modern reinforced concrete design, and its principles underpin every calculation in the RCC syllabus. In this chapter we have distinguished between the limit state of collapse, which protects safety against flexure, shear, torsion and buckling, and the limit state of serviceability, which protects the performance of the structure through deflection, cracking and vibration controls. We have studied the partial safety factors that convert characteristic values into design values, applied to loads as 1.5 and to concrete and steel as 1.5 and 1.15 respectively. We have also examined the idealised stress-strain curves of concrete and steel, the rectangular stress block of depth 0.8 Xu, and the four fundamental design assumptions of plane sections remaining plane, maximum concrete strain of 0.0035, ignoring of concrete tension, and the limiting design stress in steel of 0.87 fy. These ideas are not confined to this chapter, because they are used in the design of every beam, slab, column and footing in the subsequent chapters. A candidate who masters the concept of partial safety factors and the stress block constants will find the entire limit state design of reinforced concrete members systematic and easy to score in.