Subject: Civil Engineering Chapter: Reinforced Cement Concrete Topic: 9.7 Columns
A column is a vertical structural member that primarily transmits compressive loads from the slabs, beams and roofs above it down to the footings and the ground below. Columns are the most critical members of a building frame, because the failure of a single column can lead to the collapse of a large portion of the structure. In reinforced concrete, columns are designed to resist axial compression, and often a combination of axial load and bending moment, since loads are rarely perfectly concentric. The design of columns is governed by the limit state method, and it involves the determination of the load-carrying capacity of the concrete and steel, the check for slenderness, and the provision of longitudinal reinforcement and lateral ties.
Columns are classified in several ways. On the basis of the type of loading, a column is called an axially loaded column when the load acts along the centroidal axis, and an eccentrically loaded column when the load is offset, producing bending. On the basis of slenderness, a column is called a short column when its slenderness ratio, the ratio of effective length to the least lateral dimension, is less than or equal to 12, and a slender or long column when this ratio exceeds 12. Short columns fail by crushing of concrete, while long columns fail by buckling before the concrete reaches its crushing strength, so the design of long columns includes an additional moment due to the eccentricity of the buckled column.
The reinforcement in a column consists of longitudinal bars, which carry the load along with the concrete, and transverse reinforcement, which consists of lateral ties or helical reinforcement. The longitudinal bars are placed symmetrically in the column section, near the perimeter, and they increase the load capacity and improve the ductility of the member. The lateral ties serve three purposes: they hold the longitudinal bars in position during concreting, they prevent the premature buckling of the longitudinal bars under compression, and they confine the concrete core, increasing its strength and ductility. The spacing and diameter of the ties are specified by the code.
In limit state design, the ultimate load capacity of a short axially loaded column is computed from the design strengths of the materials. The axial load is resisted by the concrete and the steel together, and the capacity is given by Pu = 0.4 fck Ac + 0.67 fy Asc, where Ac is the area of concrete and Asc is the area of longitudinal steel. In this formula, the factor 0.4 fck is the design compressive strength of concrete in a column, which is lower than the flexural design stress of 0.67 fck because the long-term sustained compression in a column causes creep, which reduces the effective stress in the concrete. The factor 0.67 fy is the design compressive stress in the steel.
The code requires that the longitudinal reinforcement in a column be at least 0.8 percent of the gross cross-sectional area, and not more than 6 percent, to keep the column economical and the concrete workable. The minimum number of longitudinal bars is four for a rectangular column and six for a circular column. The diameter of the longitudinal bars must not be less than 12 mm, and the bars must be spaced so that the clear distance between them does not exceed 300 mm. The cover to the longitudinal bars is at least 40 mm, or the bar diameter, whichever is greater, for a column that is not exposed to weather.
The load capacity computed from the formula assumes that the column is short, that is, its slenderness ratio is not more than 12. For such columns, the failure is by crushing, and the design load of the column is the capacity Pu. When the actual load on the column is known, the required area of steel is obtained by subtracting the concrete contribution from the total load, so Asc = (Pu - 0.4 fck Ag) divided by (0.67 fy - 0.4 fck), where Ag is the gross area of the section. This formula is used in design when the column size is already fixed.
A column is slender when its slenderness ratio exceeds 12, and slender columns fail by buckling before the concrete reaches its crushing strength. The slenderness ratio of a column is the ratio of its effective length to its least lateral dimension, for a rectangular column, or to the diameter, for a circular column. The effective length of a column depends on its end conditions, that is, whether the ends are fixed, hinged or free. For a column fixed at both ends, the effective length is 0.65 times the actual length; for a column with both ends effectively held in position and restrained against rotation, the factor is 0.65 to 0.75; for a column pinned at both ends, the effective length equals the actual length; and for a cantilever column fixed at the base and free at the top, the effective length is twice the actual length.
In the design of a slender column, the additional moment caused by the buckling eccentricity must be considered. The total moment for design is the sum of the primary moment due to the load eccentricity and the additional moment due to the lateral deflection. The additional moment is computed from the magnification of the eccentricity, which depends on the effective length, the depth of the section and the load. The code prescribes that the additional moment be computed from a formula involving the slenderness ratio, so that the section is designed for the magnified moment rather than the primary moment alone.
The reduction in the load-carrying capacity of a slender column is significant, so the designer always tries to keep columns short by providing lateral bracing or by limiting the height. In frames, columns are braced by the floor slabs and beams, which reduce their effective lengths. The classification of a column as short or slender, and the computation of the effective length from the end conditions, are frequent examination questions, both conceptual and numerical. The effective length factors are among the most tested values in the column chapter.
Lateral ties are provided in all columns that use longitudinal bars. For a rectangular column, the ties are closed loops of mild or high yield steel that enclose the longitudinal bars, and for a circular column, either circular ties or helical reinforcement is used. The diameter of the lateral ties must not be less than 6 mm or one-quarter of the diameter of the largest longitudinal bar, whichever is greater. The pitch, or spacing, of the ties must not exceed the smallest of the least lateral dimension of the column, 16 times the diameter of the smallest longitudinal bar, and 300 mm.
The ties must be arranged so that every alternate longitudinal bar is held in position by a tie corner, and every longitudinal bar must be restrained at intervals along the column height. When the longitudinal bars are more than 75 mm apart, additional ties are required to hold the intermediate bars. The ties prevent the longitudinal bars from buckling outward under compression, which would occur at a load much smaller than the crushing load if the bars were unconfined. By confining the concrete core, the ties also increase the ductility of the column and improve its behaviour under earthquake loading.
Helical reinforcement is used in circular columns, where the continuous helix provides better confinement than separate ties. The pitch of the helix must not exceed 75 mm, and the advantage of helical reinforcement is that the load capacity of the column can be increased by the confinement factor, which multiplies the concrete contribution. The code gives a ratio of the volume of helical reinforcement to the volume of the concrete core, below which the helical column is treated as a tied column. Helical columns are used where high ductility is required, such as in bridge piers and columns in seismic regions.
| Type of Column | Condition | Mode of Failure |
|---|---|---|
| Short column | Slenderness ratio <= 12 | Crushing of concrete |
| Slender column | Slenderness ratio > 12 | Buckling before crushing |
| Axially loaded column | Load along centroid | Uniform compression |
| Eccentrically loaded column | Load offset from centroid | Combined compression and bending |
| Requirement | Value |
|---|---|
| Minimum longitudinal steel | 0.8% of gross area |
| Maximum longitudinal steel | 6% of gross area |
| Minimum number of bars (rectangular) | 4 |
| Minimum number of bars (circular) | 6 |
| Minimum bar diameter | 12 mm |
| Maximum clear spacing of bars | 300 mm |
| Minimum tie diameter | 6 mm or 1/4 of largest bar |
| Maximum tie spacing | Least of lateral dimension, 16 bar dia, 300 mm |
flowchart TD
A[Columns] --> B[Classification]
A --> C[Short column capacity]
A --> D[Slender columns]
A --> E[Longitudinal reinforcement]
A --> F[Lateral ties and helix]
B --> B1[Short vs slender]
B --> B2[Axial vs eccentric]
C --> C1[Pu = 0.4 fck Ac + 0.67 fy Asc]
C --> C2[Crushing failure]
D --> D1[Slenderness ratio > 12]
D --> D2[Effective length and end conditions]
D --> D3[Additional moment due to buckling]
E --> E1[0.8% to 6% of gross area]
E --> E2[Minimum 12 mm bars]
F --> F1[Ties hold bars and prevent buckling]
F --> F2[Helix for circular columns]
The following diagrams show the reinforcement arrangement in columns and the concept of effective length for different end conditions.
Columns are the backbone of any framed structure, and their design is one of the most safety-critical topics in reinforced concrete. In this chapter we have classified columns into short and slender on the basis of the slenderness ratio of 12, and into axially loaded and eccentrically loaded on the basis of the load path. We have computed the load capacity of a short axially loaded column using Pu = 0.4 fck Ac + 0.67 fy Asc, understood why the concrete stress is taken as 0.4 fck rather than 0.67 fck because of creep, and studied the effective length factors of 0.65, 1.0 and 2.0 for different end conditions. We have also covered the requirements of longitudinal reinforcement, with a minimum of 0.8 percent and a maximum of 6 percent of the gross area, and the design of lateral ties and helical reinforcement, including the limits on diameter and spacing. The distinction between crushing failure in short columns and buckling failure in slender columns, and the additional moment in slender columns, have been examined. Column questions combine the material capacities with slenderness checks, and they test the candidate's understanding of the safety of vertical members. A candidate who masters the capacity formula, the slenderness ratio and the reinforcement limits will handle both the numerical and conceptual questions of this chapter with confidence, and will be well prepared for the design of footings that support these columns in the next chapter.