🏗️ Civil Engineering

9.8 Footings

Start MCQ Practice →

9.8 Footings

Subject: Civil Engineering Chapter: Reinforced Cement Concrete Topic: 9.8 Footings

1. Introduction

A footing is the lowermost part of a foundation that transmits the load of a column or a wall to the soil below. The function of a footing is to spread the concentrated load from the column over a sufficiently large area of soil so that the pressure on the soil does not exceed its safe bearing capacity. Footings are among the most important structural elements because the entire load of the structure rests on them, and any failure of a footing leads to the failure of the whole building. Reinforced concrete footings are classified into several types, including isolated footings under individual columns, combined footings under two or more columns, strap footings, and raft footings under the entire building, and the choice depends on the loads, the soil conditions and the proximity of the columns.

The design of a footing involves two separate and equally important aspects: the geotechnical aspect, which fixes the size of the footing so that the soil pressure remains within the safe bearing capacity, and the structural aspect, which provides the reinforcement so that the footing can resist the bending moment and shear force produced by the upward soil pressure. The footing behaves like an inverted slab or cantilever, because the load from the column acts downward while the soil reaction acts upward, so the bending causes tension on the bottom face of the footing, and the main reinforcement is therefore placed at the bottom, near the soil.

The design of a footing must also satisfy several serviceability and detailing requirements. The depth of the footing must be sufficient to resist the bending moment without excessive reinforcement, to resist the shear at the critical sections, and to provide adequate development length for the column bars that project into the footing. In this chapter we will study the types of footings, the determination of the footing size, the design of isolated and combined footings, and the checks for bending, shear and bond that govern the design.

2. Types of Footings and Selection Criteria

Isolated footings are provided under individual columns and are the most common type when the columns are well spaced and the loads are moderate. An isolated footing is usually square or rectangular in plan, and it may be a simple pad footing with a uniform thickness, or a stepped or sloped footing where the thickness reduces towards the edges to save concrete. The area of the footing is found by dividing the total load, including the self weight of the footing and the weight of the soil above it, by the safe bearing capacity of the soil.

Combined footings are provided when two columns are close together and their individual footings would overlap, or when a column is located at the property line and its footing cannot be extended on that side. A combined footing supports two or more columns and is designed so that the centre of gravity of the column loads coincides with the centre of the footing, which ensures a uniform soil pressure. When the columns are so close that even a combined rectangular footing is not practical, a strap footing, which connects the two footings with a stiff strap beam, is used. When the loads are very large or the soil is weak, a raft or mat footing, which covers the entire building area, is provided, and it also helps to reduce the differential settlement between columns.

The selection of the footing type depends on the magnitude of the column loads, the safe bearing capacity of the soil, the spacing of the columns and the available clearances at the property boundaries. The structural behaviour of a footing is essentially that of a slab, with upward soil pressure acting as the load and the column acting as the support. For an isolated footing, the critical bending moment is computed at the face of the column, and the shear is checked at two critical sections, one for one-way shear at a distance equal to the effective depth from the column face, and one for two-way or punching shear at a distance equal to half the effective depth from the column face.

3. Design of an Isolated Footing

The design of an isolated square footing begins with the determination of the footing size. If the load on the column is P and the safe bearing capacity of the soil is q, the required area of the footing is (P + Wf) divided by q, where Wf is the weight of the footing and the soil above it, often taken as 10 percent of P. The side of the square footing is the square root of the required area. Once the size is fixed, the net upward soil pressure is computed as the column load divided by the actual area of the footing, and this net pressure, which excludes the weight of the footing itself, is used for the structural design.

The depth of the footing is fixed by the shear requirements, because shear governs the thickness of footings. The one-way shear is checked at a section at a distance d from the face of the column, and the shear stress must not exceed the design shear strength of the concrete. The two-way or punching shear is checked at a critical section at a distance d/2 from the column face, around the perimeter of the column, and the punching shear stress must not exceed the permissible value given by the code. The effective depth is increased until both shear checks are satisfied.

The bending moment in the footing is computed at the face of the column, and for a square footing it is Mu = p multiplied by B multiplied by (L minus c) squared divided by 8, where p is the net soil pressure, B is the width of the footing, L is the length, and c is the column dimension. The main reinforcement is provided at the bottom in both directions for a square footing, since the footing bends in both directions like a two-way slab. The area of steel in each direction is computed from the moment, and the spacing must satisfy the code limits, with the maximum spacing of the bars not exceeding the smaller of 3 times the effective depth and 300 mm.

4. Combined Footings and Detailing

A combined footing is designed when the individual footings of two columns would overlap. The shape of the combined footing is usually rectangular or trapezoidal, and the plan is designed so that the centre of gravity of the column loads coincides with the centre of the footing area, giving a uniform soil pressure. The longitudinal bending moment in the footing is computed as if the footing were a beam supported by the two columns and loaded by the upward soil pressure, and the reinforcement is provided accordingly, with negative moment reinforcement at the top over the columns and positive moment reinforcement at the bottom between the columns.

The transverse reinforcement in a combined footing is designed for the transverse bending, treating the footing as a set of transverse beams. The transverse bending moment is significant under each column, and the transverse reinforcement is concentrated in a band under the columns, with a smaller amount of steel distributed in the remainder of the footing. The combined footing is therefore reinforced with longitudinal bars for the longitudinal moments and transverse bars for the transverse moments, and the design is considerably more involved than that of an isolated footing.

In the detailing of all footings, the column bars must be anchored into the footing by providing a development length beyond the top of the footing. The reinforcement is placed at the bottom with a clear cover of at least 40 mm, because the footing is in contact with soil and is exposed to moisture. The bars are tied to form a mesh, and the edge distance of the bars is maintained. A minimum percentage of reinforcement of 0.12 percent for Fe415 and Fe500 steel is provided in the footings, and the spacing limits are applied as in slabs. Proper compaction of the soil and a layer of lean concrete below the footing improve the load transfer and protect the reinforcement from corrosion.

5. Quick Revision Tables

Table 1: Types of Footings

Type of Footing Use Load Transfer
Isolated footing Single column, well spaced Column to soil over footing area
Combined footing Two close columns Shared footing, uniform pressure
Strap footing Column at property line Connected by stiff strap beam
Raft footing Large loads, weak soil Entire building to soil
Wall footing Load-bearing walls Wall strip to soil

Table 2: Checks in Footing Design

Check Critical Section Purpose
Soil pressure Base of footing Size of footing for safe bearing capacity
One-way shear At distance d from column face Prevents beam-type shear failure
Punching shear At distance d/2 from column face Prevents two-way shear failure
Bending moment At face of column Determines bottom reinforcement
Development length Anchorage of column bars Ensures full bond in footing

6. Mind Map

flowchart TD
    A[Footings] --> B[Types]
    A --> C[Size of footing]
    A --> D[Design of isolated footing]
    A --> E[Combined footings]
    A --> F[Detailing]
    B --> B1[Isolated footing]
    B --> B2[Combined footing]
    B --> B3[Strap footing]
    B --> B4[Raft footing]
    C --> C1[Area = load / safe bearing capacity]
    C --> C2[Net upward soil pressure for design]
    D --> D1[Depth governed by shear]
    D --> D2[Bending at column face]
    D --> D3[Reinforcement at bottom in both directions]
    E --> E1[Centre of gravity coincides with load centre]
    E --> E2[Longitudinal and transverse moments]
    F --> F1[Development length for column bars]
    F --> F2[Minimum cover 40 mm]

7. Important Diagrams (SVG)

The following diagrams show the load transfer through an isolated footing and the critical sections for shear and bending.

Isolated Footing under a Column COLUMN P FOOTING SLAB (B x B) Main reinforcement at bottom Upward soil pressure Footing bends like an inverted slab; tension at bottom face Golden Rule The upward soil pressure bends the footing like a cantilever, so steel goes at the bottom.

Critical Sections in a Footing PLAN Column c x c d/2 punching perimeter one-way shear section at d from column Two-way shear: perimeter at d/2 from column face One-way shear: section at distance d from column face Bending moment: critical at the face of the column Golden Rule The depth of a footing is governed by shear, checked at d and d/2 from the column face.

8. Common Mistakes

  1. Many students use the net upward soil pressure in the size calculation instead of the gross pressure including the footing self weight.
  2. A frequent error is to place the main reinforcement at the top of the footing; the tension is on the bottom face because of the upward soil pressure.
  3. Some candidates check only one-way shear and forget the punching shear, which is critical for footings and usually governs the depth.
  4. Students often fail to account for the weight of the footing and the soil above it when computing the required area, leading to an undersized footing.
  5. A common mistake is to compute the bending moment at the centre of the column; the critical section for the bending moment is the face of the column.
  6. Many candidates forget the minimum cover of 40 mm for footings, since the footing is in direct contact with the soil.
  7. Some students design a combined footing without ensuring that the centre of gravity of the loads coincides with the centre of the footing, causing a non-uniform soil pressure.
  8. Candidates often forget to anchor the column bars into the footing by providing the required development length.

9. Exam Tips

  1. Remember the design sequence for a footing: fix the size from the safe bearing capacity, compute the net soil pressure, fix the depth from shear, and design the bending steel at the bottom.
  2. Learn the two shear checks: one-way shear at distance d and punching shear at distance d/2 from the column face, since the depth is governed by these.
  3. Note that the critical bending moment is at the face of the column and the critical shear sections are near the column face.
  4. Remember the minimum reinforcement and cover requirements: 0.12 percent steel for Fe415 and Fe500, and a cover of 40 mm.
  5. Note that a combined footing must be proportioned so that the resultant of the column loads passes through the centre of the footing.
  6. Remember the main reinforcement of a footing is placed at the bottom in both directions for a square footing.
  7. Practise the relation area of footing = total load divided by safe bearing capacity, since this is the first step of every footing problem.

10. Conclusion

Footings connect the superstructure to the soil and distribute the concentrated column loads over an area that the soil can safely support, making their design both a geotechnical and a structural exercise. In this chapter we have classified footings into isolated, combined, strap and raft types, selected the type on the basis of loads, soil capacity and column spacing, and designed isolated footings step by step from the size determination using the safe bearing capacity to the reinforcement design using the net upward soil pressure. We have emphasised that the depth of a footing is governed by the shear requirements, checked at the one-way section at distance d and the punching section at distance d/2 from the column face, and that the critical bending moment occurs at the face of the column, with the main steel placed at the bottom face because the footing bends like an inverted cantilever. The design of combined footings, with the alignment of the centre of gravity and the longitudinal and transverse reinforcement, and the detailing requirements of cover, development length and minimum steel have also been covered. Footing questions test the candidate's ability to combine the soil pressure, the shear checks and the bending design in a single member, and they are a favourite in examinations for their completeness. A candidate who masters the footing design sequence will handle these problems systematically and secure high marks, completing the design chain from beams and columns to the foundation.