🏗️ Civil Engineering

3.9 Columns and Struts

Start MCQ Practice →

3.9 Columns and Struts

Subject: Civil Engineering Chapter: Strength of Materials Topic: 3.9 Columns and Struts

1. Introduction

When a slender member is subjected to a compressive axial load, it may fail not by crushing but by a sudden lateral bending called buckling, long before the compressive stress reaches the crushing strength of the material. Such members are called columns or struts. A column is a vertical member carrying an axial compressive load, such as the pillars of a building or a bridge pier, while a strut is any compression member of a structure, which may be inclined or horizontal, such as the compression member of a roof truss. The study of columns and struts is the study of this instability: how a long, slender member suddenly bends sideways under a compressive load and loses its load-carrying capacity.

The behaviour of a column depends strongly on its slenderness. A short, stocky column fails by crushing, because the compressive stress reaches the material strength before buckling becomes possible. A long, slender column fails by buckling, because it deflects laterally and loses stability at a load much smaller than the crushing load. Between these two extremes lie intermediate columns, which fail by a combination of crushing and buckling. The critical load at which a long column begins to buckle is called the Euler's critical load, named after Leonhard Euler, who derived the formula in 1757 and produced one of the earliest results of structural stability theory.

In this chapter we will study Euler's formula for the buckling load of long columns, the concept of effective length and the four end conditions, the slenderness ratio, and the empirical Rankine's formula which covers both short and long columns. We will solve numerical problems comparing Euler's load with the crushing load and determining the safe dimensions of compression members. Columns and struts form a compact but highly testable chapter, and its formulas appear regularly in civil engineering examinations.

2. Euler's Formula for the Buckling Load

Consider a long slender column of length L, modulus of elasticity E and minimum moment of inertia I, pin-ended at both ends, subjected to an axial compressive load P. When P is small, the column remains straight. As P is increased, a critical value is reached at which the straight form becomes unstable and the column buckles sideways into a curved shape. Euler showed that this critical buckling load is given by:

P crit = pi^2 E I / L^2

The buckling load depends on the stiffness of the column, measured by E and I, and inversely on the square of the length. For a given material and cross-section, the buckling load is governed by the minimum moment of inertia of the section, because the column always buckles in the direction in which it is weakest. The critical stress corresponding to this load is:

sigma crit = P crit / A = pi^2 E / (L/r)^2

where r is the least radius of gyration of the section and the ratio L/r is the slenderness ratio. The slenderness ratio is the single most important parameter of a column: as it increases, the column becomes more slender and the critical stress falls.

Worked Example 1

A mild steel column of length 3 m, both ends pin-jointed, has a circular cross-section of diameter 40 mm. If E = 200000 N/mm2, find the Euler's critical buckling load.

Solution: Moment of inertia, I = pi d4 / 64 = pi x 40^4 / 64 = pi x 2560000 / 64 = 125664 mm4. Length, L = 3000 mm. Critical load, P crit = pi^2 E I / L^2 = 9.8696 x 200000 x 125664 / (3000 x 3000) = 2.4806 x 10^11 / 9000000 = 27562 N. Hence the Euler's critical load is approximately 27.56 kN.

3. Effective Length and End Conditions

The buckling load of a column depends strongly on how the ends are supported, because the end conditions determine the shape of the buckled curve and hence the effective length. The effective length Le is the length of an equivalent pin-ended column that has the same buckling load, and Euler's formula is written generally as:

P crit = pi^2 E I / Le^2

where Le = K L and K is the effective length factor. For a column with both ends pinned, Le = L. For a column fixed at both ends, the points of zero moment are at quarter points, so the effective length is L/2. For a column fixed at one end and free at the other, like a flagpole, the free end sways, and the effective length is 2L. For a column fixed at one end and pinned at the other, the effective length is 0.7L.

The four standard end conditions and their effective lengths are one of the most frequently asked facts in this chapter. Both ends pinned gives Le = L; one end fixed and the other free gives Le = 2L; both ends fixed gives Le = L/2; one end fixed and the other pinned gives Le = 0.7L. A column fixed at both ends has the smallest effective length and therefore the highest buckling load, while a cantilever column with one free end has the largest effective length and the lowest buckling load.

Worked Example 2

A column of length 4 m and uniform section with I = 8 x 10^6 mm4 is made of a material with E = 200000 N/mm2. Find the Euler's critical load if the column is fixed at one end and free at the other.

Solution: Effective length, Le = 2 L = 2 x 4000 = 8000 mm. Critical load, P crit = pi^2 E I / Le^2 = 9.8696 x 200000 x 8 x 10^6 / (8000^2) = 1.579 x 10^13 / 64000000 = 246770 N. Hence the Euler's critical load is approximately 246.77 kN.

4. Slenderness Ratio and Rankine's Formula

The slenderness ratio is the ratio of the effective length of a column to its least radius of gyration:

Slenderness ratio = Le / r

where r = sqrt(I/A) is the radius of gyration about the axis of least moment of inertia. A short column has a low slenderness ratio and fails by crushing, while a long column has a high slenderness ratio and fails by buckling. The limiting slenderness ratio at which Euler's formula ceases to apply is found by equating the Euler's critical stress to the crushing stress, and for most structural materials long column behaviour begins around a slenderness ratio of 80 to 120.

Rankine's formula is an empirical formula that covers the whole range from short to long columns. It combines the crushing load with the Euler's load in a single expression:

1 / P = 1 / P crushing + 1 / P Euler

which gives P = sigma c A / (1 + a (Le/r)^2), where sigma c is the crushing stress and a is the Rankine's constant, equal to sigma c / pi^2 E. For mild steel, sigma c is about 320 N/mm2 and the constant a is about 1/7500. Rankine's formula approaches the crushing load for short columns and approaches Euler's load for long columns, and it is the standard formula used in design codes.

Worked Example 3

A column of length 3 m with both ends pinned has a circular section of diameter 100 mm. If the crushing stress is 320 N/mm2, E = 200000 N/mm2 and Rankine's constant a = 1/7500, find the safe load using Rankine's formula.

Solution: Area, A = pi x 100^2 / 4 = 7854 mm2. Moment of inertia, I = pi d4 / 64 = pi x 10^8 / 64 = 4908739 mm4. Radius of gyration, r = sqrt(I/A) = sqrt(4908739/7854) = sqrt 625 = 25 mm. Slenderness ratio, Le/r = 3000/25 = 120. Rankine's load, P = sigma c A / (1 + a (Le/r)^2) = 320 x 7854 / (1 + (1/7500) x 120^2) = 2513280 / (1 + 1.92) = 2513280 / 2.92 = 860712 N. Hence the Rankine's load is approximately 860.7 kN.

5. Quick Revision Tables

Table 1: Effective Length for Different End Conditions

End Condition Effective Length Le Effective Length Factor K
Both ends pinned L 1.0
One end fixed, one end free 2L 2.0
Both ends fixed L/2 0.5
One end fixed, one end pinned 0.7L 0.7

Table 2: Euler versus Rankine

Feature Euler's Formula Rankine's Formula
Applicability Long columns All columns
Formula pi^2 E I / Le^2 sigma c A / (1 + a(Le/r)^2)
Failure mode Buckling Crushing + buckling
Depends on E and I sigma c, a and slenderness
Limitation Fails for short columns Empirical constant a

6. Mind Map

flowchart TD
    A[Columns and Struts] --> B[Definition]
    A --> C[Euler's formula]
    A --> D[End conditions]
    A --> E[Slenderness ratio]
    A --> F[Rankine's formula]
    B --> B1[Column - vertical compression member]
    B --> B2[Strut - any compression member]
    C --> C1[P = pi^2 E I / Le^2]
    C --> C2[Applies to long columns]
    D --> D1[Pinned-pinned Le = L]
    D --> D2[Fixed-free Le = 2L]
    D --> D3[Fixed-fixed Le = L/2]
    D --> D4[Fixed-pinned Le = 0.7L]
    E --> E1[Le / r]
    E --> E2[Short columns crush]
    E --> E3[Long columns buckle]
    F --> F1[P = sigma c A / (1 + a(Le/r)^2)]
    F --> F2[Valid for all columns]

7. Important Diagrams (SVG)

The following diagrams show the buckled shapes of columns with different end conditions and the effect of slenderness ratio on the failure mode.

Buckled Shapes for Different End Conditions Pinned-Pinned Le = L Fixed-Free Le = 2L Fixed-Fixed Le = L/2 Smaller effective length gives a higher buckling load Golden Rule Effective lengths: pinned L, fixed-free 2L, fixed-fixed L/2, fixed-pinned 0.7L.

Effect of Slenderness Ratio on Failure Short column Crushing Intermediate Crushing + Buckling Long column Buckling As slenderness ratio Le/r increases, failure changes from crushing to buckling Euler's formula applies to long columns, Rankine's formula to all columns Golden Rule Short columns fail by crushing, long columns by buckling, and slender members use Euler's formula.

8. Common Mistakes

  1. Many students use the full length L in Euler's formula when the column is fixed at both ends; the correct effective length is L/2.
  2. A frequent error is to use the maximum moment of inertia of the section instead of the minimum, but a column always buckles about the weaker axis.
  3. Some candidates forget to convert the length to millimetres when E is in N/mm2, producing buckling loads that are wrong by orders of magnitude.
  4. Students often apply Euler's formula to short columns, where the failure is by crushing and Euler's formula gives a load higher than the crushing load.
  5. A common mistake is to write Euler's formula as pi^2 E I / L instead of pi^2 E I / L^2, which changes the dimensions completely.
  6. Many candidates confuse the radius of gyration with the actual radius and compute the wrong slenderness ratio.
  7. Some students take the effective length factor of a fixed-pinned column as 0.5 or 1.0 instead of the correct 0.7.
  8. Candidates often forget that Euler's stress sigma = pi^2 E / (Le/r)^2 is derived by dividing the critical load by the area, and use the crushing stress instead.

9. Exam Tips

  1. Memorise Euler's formula P = pi^2 E I / Le^2 and write it with the effective length Le, never with the actual length alone.
  2. Learn the four end conditions and effective lengths: pinned L, fixed-free 2L, fixed-fixed L/2, fixed-pinned 0.7L.
  3. Remember that the buckling load uses the minimum moment of inertia, since the column buckles in its weakest direction.
  4. Note that the slenderness ratio Le/r determines the failure mode; a high slenderness ratio means buckling governs.
  5. Use Rankine's formula P = sigma c A / (1 + a (Le/r)^2) for problems where the column may be short, and remember a = sigma c / (pi^2 E).
  6. Remember that for mild steel the Rankine's constant a is about 1/7500 and the crushing stress about 320 N/mm2.
  7. Practise problems that compare Euler's load with the crushing load to decide whether a column is long or short, a standard examination question.

10. Conclusion

Columns and struts bring a completely new failure mechanism into structural engineering, because a compression member can lose its strength by buckling even when the material itself is far from failing. In this chapter we have derived Euler's formula for the critical buckling load, introduced the concept of effective length with its four end conditions, studied the slenderness ratio and its effect on the failure mode, and covered Rankine's empirical formula which unifies the crushing and buckling behaviour. We have seen that the buckling load depends on the stiffness EI and on the square of the effective length, that a column fixed at both ends is the strongest because it has the smallest effective length, and that the weakest direction of the section always governs. These ideas are used in the design of every column in a building, every strut in a truss, and every compression chord of a bridge girder, and they are equally important in steel, concrete and timber design. A candidate who has memorised Euler's formula, the effective length factors and the slenderness ratio concepts will be able to solve the full range of column questions, from quick one-mark facts to detailed design numericals, with confidence in the examination hall.