🏗️ Civil Engineering

10.2 Riveted and Bolted Connections

Start MCQ Practice →

10.2 Riveted and Bolted Connections

Subject: Civil Engineering Chapter: Steel Structures Topic: 10.2 Riveted and Bolted Connections

1. Introduction

No steel structure can be built without connections, because steel members are fabricated in the factory and assembled at the site. A connection is the junction at which two or more steel members are joined together so that the loads are transferred safely from one member to the next. The strength of a steel structure is decided not only by the strength of its individual members but also, and very often decisively, by the strength of its connections. Many failures in steel structures have been traced to poorly designed or badly executed connections, so for a civil engineer the design of riveted and bolted connections is one of the most important parts of the steel structures syllabus, and questions on fasteners appear in almost every competitive examination.

Historically, riveting was the most common method of connecting steel members, and although riveting is now largely replaced by welding and high-strength friction grip bolts, its principles are still taught because the design logic, the failure modes and the terminology are common to all types of fasteners. A rivet is a cylindrical steel pin with a head at one end, which is driven red-hot through holes punched or drilled in the two overlapping members and then hammered to form a head on the other side. On cooling, the rivet contracts longitudinally and clamps the plates together. Bolts, on the other hand, are threaded fasteners tightened with nuts, and they allow members to be dismantled easily, which makes them ideal for site connections and structures that need to be erected or dismantled repeatedly.

In this chapter we will study the types of rivets and bolts, the permissible stresses in them, the different failure modes of a riveted or bolted joint, the concepts of pitch, gauge, edge distance and efficiency of the joint, the design rules for lap and butt joints, and the design of bearing and friction type bolted connections as per IS 800. We will also solve worked examples to find the strength of a joint and the number of rivets required for a given load. This chapter builds directly on the mechanical properties of steel studied earlier, and it provides the basis for the chapter on welded connections that follows.

2. Types of Rivets and Bolts

Rivets are classified by the shape of their heads and by the purpose they serve. The common types are the snap head rivet, used for general structural work; the pan head rivet, used where a flatter head is needed; the countersunk head rivet, used where the rivet head must not project above the surface; and the flat countersunk head rivet. Rivets are driven in two ways: in the hot or power driven process the rivet is heated red and driven by a pneumatic hammer, and on cooling it shrinks and clamps the plates together; in the cold or hand driven process the rivet is driven without heating, and this is used for small rivets in plates of limited thickness. The diameter of a rivet hole is taken as the nominal diameter of the rivet plus 1.5 mm to allow for driving.

Bolts used in steel construction are of three main types. Black or ordinary bolts are turned or forged bolts of mild steel with rolled threads, and they are used for temporary connections and lightly loaded members. Turned and fitted bolts are machined so that the shank is a close fit in the hole, and they are used where resistance to slip is required. High strength friction grip (HSFG) bolts are made of high tensile steel, tightened with a calibrated torque wrench to a specified proof load, so that the plates are clamped firmly and load is transferred by friction between the faying surfaces. HSFG bolts are used for important connections such as splices, crane girders and bridge joints where vibration and reversal of load occur.

In IS 800:2007 the design of bolts is based on either the bearing type connection, where the load is carried by the bearing of the bolt shank against the plate and by the shear resistance of the bolt, or the friction (slip resistant) type connection, where the load is carried entirely by friction between the plates and there is no bearing. The nominal diameter of bolts ranges from 12 mm to 36 mm in steps, and the standard holes for bolts are about 1.5 mm larger than the bolt diameter for clearance. The number of bolts in a connection must be such that the total strength of the bolts, in shear and bearing, is at least equal to the load to be transmitted.

3. Failure Modes of a Riveted or Bolted Joint

A riveted or bolted joint can fail in several distinct ways, and the design must check each mode. The first mode is shearing of the rivet or bolt, in which the shank is cut across its cross-section. A rivet may be in single shear when only one plane is being sheared, as in a lap joint, or in double shear when two planes are sheared, as in a double cover butt joint. A rivet in double shear can carry about twice the load of a rivet in single shear, since the total shear area is doubled. The second mode is bearing failure, in which the pressure of the rivet shank crushes the plate material around the hole, and this is checked by multiplying the projected area of the rivet hole by the permissible bearing stress.

The third mode is the tearing of the plate at the net section, which occurs when the plate is pulled apart along a line passing through the rivet holes. The tearing strength is calculated using the net area of the plate, which is the gross area minus the area removed by the holes. The fourth mode is the shearing of the plate edge, in which the plate tears from the hole to the edge, and this is prevented by keeping the edge distance sufficiently large. The fifth mode is the splitting of the plate margin between the rivet and the edge. The strength of the joint in any mode is obtained by multiplying the permissible stress in that mode by the corresponding area, and the strength of the joint is the smallest of the values obtained, but it must not be less than the load to be transferred.

The design also requires that the gross sectional area of the plate is reduced by the holes, and the ratio of the net tearing strength of the plate to the gross tearing strength is called the efficiency of the joint. For a single riveted lap joint the efficiency is usually between 50 and 60 percent, whereas a double riveted double cover butt joint can have an efficiency of about 80 to 90 percent. The pitch of the rivets is the distance between the centres of adjacent rivets measured along the direction of load, the gauge is the distance between two adjacent rivet lines measured perpendicular to the direction of load, and the edge distance is the distance from the centre of the end rivet to the edge of the plate. The minimum pitch is 2.5 times the diameter of the rivet hole, and the maximum pitch is governed by the requirement that the plate must not buckle between rivets.

4. Design Strength of Bolted Connections as per IS 800

As per IS 800:2007, the design shear strength of a bolt in a bearing type connection is calculated as Vdsb = fu/(root3 x 1.25) times the shear area times the number of shear planes, where fu is the ultimate stress of the bolt. The design bearing strength of the bolt on the plate is Vdpb = 2.5 x kb x fu x d x t, where d is the nominal diameter of the bolt, t is the thickness of the connected plate, and kb is a coefficient depending on the edge distance, pitch and the ultimate strengths of bolt and plate. The strength of the connection is governed by the smaller of the shear strength and the bearing strength, and the number of bolts is obtained by dividing the design load by the smaller design strength.

For a friction type or HSFG connection, the design slip resistance is given by Vdsf = mu_f x ne x Kh x Fo divided by gamma_mf, where mu_f is the coefficient of friction between the faying surfaces (about 0.5 for untreated mill scale), ne is the number of friction interfaces, Kh is a factor equal to 1.0 for bolts in clearance holes, and Fo is the proof load of the bolt. Since the load is transferred by friction, the bolt is not subjected to shear and bearing, but the plates must be firmly clamped by tightening the bolt to the proof load. HSFG bolts are used where the joint must not slip, as in crane girders and bridge connections.

Worked Example

A lap joint connects two plates of 12 mm thickness using 20 mm diameter bolts of grade 4.6. The permissible shear stress is 80 N/mm2 and the bearing stress is 250 N/mm2. Determine the strength of one bolt in single shear and in bearing.

Solution: Area of bolt, Ab = (pi/4) x d2 = (pi/4) x 400 = 314.16 mm2. Single shear strength = permissible shear stress x Ab = 80 x 314.16 = 25133 N, about 25.1 kN. Bearing strength = permissible bearing stress x d x t = 250 x 20 x 12 = 60000 N, about 60 kN. Hence the single bolt strength is governed by shear and is 25.1 kN.

5. Quick Revision Tables

Table 1: Failure Modes of a Riveted Joint

Failure Mode Governing Area Prevention
Shear of rivet Rivet cross-section Use double shear, more rivets
Bearing on plate Projected area d x t Increase thickness of plate
Tearing of plate Net section through holes Increase pitch or area
Edge shearing Edge distance Provide sufficient edge distance
Splitting of margin Margin between rivet and edge Keep minimum pitch and margin

Table 2: Comparison of Riveted, Bolted and HSFG Connections

Feature Riveted Ordinary bolted HSFG bolted
Load transfer Bearing and shear Bearing and shear Friction between plates
Dismantling Difficult Easy Easy
Vibration resistance Good Poor Very good
Typical use Old bridges Light structures Bridge and crane connections
Hole clearance 1.5 mm 1.5 mm 1.5 mm, but Kh = 1.0

6. Mind Map

flowchart TD
    A[Riveted and Bolted Connections] --> B[Types of fasteners]
    A --> C[Failure modes]
    A --> D[Design terms]
    A --> E[Bolted connection design]
    B --> B1[Snap head, countersunk rivets]
    B --> B2[Black bolts, turned bolts, HSFG]
    C --> C1[Shear of bolt]
    C --> C2[Bearing on plate]
    C --> C3[Tearing of plate]
    C --> C4[Edge shearing]
    D --> D1[Pitch, gauge, edge distance]
    D --> D2[Efficiency of joint]
    E --> E1[Bearing type - shear and bearing]
    E --> E2[Friction type - slip resistance]

7. Important Diagrams (SVG)

The following diagrams show the arrangement of a riveted lap joint with its pitch, gauge and edge distance, and the difference between lap and butt joints.

Single Riveted Lap Joint Top plate (overlapping) Bottom plate R R R Pitch p Pitch = distance between adjacent rivets along load Minimum pitch = 2.5 x diameter of hole Golden Rule Lap joint: rivets in single shear; butt joint with double cover: rivets in double shear.

Butt Joint with Two Cover Plates Main plate 1 Main plate 2 Top cover plate Bottom cover plate Double cover butt joint Rivet in double shear: shear area = 2 x (pi/4) d2 Strength is roughly double that of single shear Efficiency of double riveted double cover butt joint ~ 80-90 percent Golden Rule Net area for tearing = gross area minus holes; joint strength is the minimum of all modes.

8. Common Mistakes

  1. Many students forget to deduct the rivet holes when calculating the net area of the plate, and therefore overestimate the tearing strength.
  2. A frequent error is to use the rivet diameter instead of the hole diameter in strength calculations; the hole diameter is the rivet diameter plus 1.5 mm.
  3. Some candidates confuse single shear and double shear and apply the double shear factor to a lap joint, which is always in single shear.
  4. Students often forget the factor root3 and the partial safety factor 1.25 in the bolt shear formula Vdsb, and obtain unrealistically high values.
  5. A common mistake is to neglect the edge distance requirement, which leads to shearing of the plate edge before the joint reaches its capacity.
  6. Many candidates assume that ordinary black bolts and HSFG bolts behave in the same way; HSFG transfers load by friction and never yields in bearing in a slip resistant design.
  7. Students forget that the strength of the joint is the minimum of the individual failure strengths, not their sum.
  8. Some candidates use the gross area instead of the net effective area in block shear checks, giving an unsafe connection.

9. Exam Tips

  1. Memorise the definitions of pitch, gauge and edge distance, because these terminology questions appear regularly as one-mark questions.
  2. Remember that minimum pitch is 2.5 times the diameter of the rivet hole, and the maximum pitch is limited to prevent buckling of the plate edge.
  3. Learn that a lap joint has rivets in single shear while a double cover butt joint gives double shear, roughly doubling the shear strength.
  4. Remember the order of efficiency: single riveted lap joint about 50 to 60 percent, double riveted butt joint up to about 90 percent.
  5. For HSFG bolts, remember the friction coefficient of about 0.5 for untreated surfaces and that the load is transferred by friction, not bearing.
  6. Practise the worked example style: compute shear strength, bearing strength, pick the smaller, and divide the load by it to find the number of bolts.
  7. Note the partial safety factors gamma_mf for friction (about 1.25) and gamma_mb for bolts (about 1.25), which appear in numerical questions.

10. Conclusion

Riveted and bolted connections are the joints that hold a steel structure together, and their design controls the safety of the entire structure. In this chapter we have studied the different types of rivets and bolts, the three classes of bolted connections under IS 800, the five important failure modes of a joint, and the design concepts of pitch, gauge, edge distance and joint efficiency. We have solved a worked example on the shear and bearing strength of a bolt, and we have seen how the number of fasteners required is found by dividing the design load by the smaller of the two design strengths. The key discipline of the chapter is to always check every failure mode and to take the minimum strength as the governing value, while respecting the minimum and maximum spacing rules. These ideas carry directly into the next chapter on welded connections, where the same logic of strength, edge distance and efficiency is applied to weld runs. A candidate who masters the failure modes and the design formulas of this chapter will find connection design the most scoring topic in the entire steel structures syllabus.