Subject: Civil Engineering Chapter: Steel Structures Topic: 10.4 Tension Members
A tension member is a structural member that carries a load which pulls it along its longitudinal axis, so that the internal forces developed in the member are purely tensile. Tension members are the simplest members to design because the state of stress is uniform tension across the net section, and there is no risk of buckling as in the case of compression members. Common examples of tension members in steel structures are the bottom chords of roof trusses, the tie members of bowstring girders and suspension bridges, the bracing members of towers, the tie rods of trusses, the suspenders of suspension bridges and the members of lattice girders that carry tension. Because a tension member fails either by yielding of the gross section or by rupture of the net section, its design is governed by the smaller of these two failure strengths.
In a tension member, the load is transmitted through the connections at the ends, and these connections are made by riveting, bolting or welding. Since the holes for rivets and bolts reduce the area of the section, the member must be checked at the net section, which is the gross area minus the area of the holes. In addition, when the load is transmitted through some of the elements of the section only, for example through the flange only of an angle, the stress is not uniform across the section, and this must be accounted for by using the concept of shear lag and the effective net area. For competitive examinations, the design of tension members involves computing the net effective area and the design strength, and choosing a section that can carry the given load with adequate factor of safety.
In this chapter we will study the types of tension members, the failure modes of tension members, the concept of net area and its calculation, the effect of shear lag and the effective net area of angles, the design strength of tension members as per IS 800:2007, the slenderness ratio of tension members, and the design of lug angles. We will also solve worked examples on finding the net area and the safe load of a tension member. The concepts developed here, especially the calculation of net area and the design strength formulas, are used repeatedly in the design of truss members, girders and bracing systems.
Tension members may be made of a single rolled section or a combination of sections, depending on the magnitude of the load and the available space. The common sections used as tension members are flat bars, single and double angles, channels, I-sections, and built-up members with a central gusset plate. For light loads, a flat bar or a single angle is economical, while for heavier loads, two angles placed back to back on either side of a gusset plate, a channel section, or a built-up section formed from angles and plates is used. Round bars and wire ropes are used for ties and suspenders where flexibility is required.
Tension members are connected to other members at their ends, and the manner in which the load is transmitted affects the design. When the load is transmitted through all the elements of the section, such as through the full cross-section of a flat bar or through the web of an I-section, the stress distribution is uniform. When the load is transmitted through only some of the elements, such as through the legs of an angle bolted to a gusset plate, the stress distribution is not uniform, and the parts of the section that are not directly connected lag behind in carrying the load. This phenomenon is called shear lag, and it reduces the efficiency of the member.
To account for shear lag, the concept of effective net area is used. As per IS 800:2007, the net effective area of a single angle used as a tension member is calculated by an expression that adds a term to the net area of the connected leg, where the added term depends on the gross area of the outstanding leg, the shear lag coefficient and the length of the connection. The shear lag coefficient bs depends on the average of the distances from the bolt holes to the edge of the section, and the term accounts for the load that can be picked up by the outstanding leg. For a welded angle, the effective area is calculated differently, using the gross area of the section and the length of the weld.
A tension member can fail in two principal ways. The first is the yielding of the gross section, in which the entire cross-section of the member reaches the yield stress fy and the member elongates plastically. The design strength for yielding, Tdg, is calculated as the gross area Ag multiplied by fy and divided by the partial safety factor gamma_m0 = 1.10. The second mode is the rupture of the net section, in which the plate tears at the net section through the holes before the gross section yields. The design strength for rupture, Tdn, is calculated using the net effective area An and the ultimate stress fu divided by the partial safety factor gamma_m1 = 1.25, with a correction factor of 0.9 applied to account for the fact that rupture occurs at a strain smaller than the ultimate strain.
A third possible failure is the block shear failure of the connection, in which a block of the plate at the end of the member tears out along the shear plane and the tension plane together. Block shear is checked at the connection by combining the shear strength along the shear planes with the tensile strength along the tension plane, and the design block shear strength is taken as the larger of the two possible combinations. In practice, the design strength of a tension member is the minimum of the gross section yielding strength, the net section rupture strength and the block shear strength. The member is then safe if this design strength is greater than or equal to the factored design load.
The slenderness ratio of a tension member is defined as the ratio of the effective length to the radius of gyration of the section. Although tension members do not buckle, a long tension member may vibrate or sag under its own weight, and therefore IS 800 limits the maximum slenderness ratio of a tension member to 400. This limit ensures that the member remains taut and does not sag excessively between the connections. The member is considered satisfactory if the slenderness ratio is within the limit, and a tension member can be designed to be much longer than a compression member of the same section because there is no buckling.
A tension member of a roof truss is made of a single angle ISA 90 x 60 x 8, with gross area 1150 mm2, connected by one leg of 90 mm through a single row of 20 mm diameter rivets. Calculate the net effective area of the member.
Solution: Area of hole = 20 + 1.5 = 21.5 mm hole diameter, hole area = 21.5 x 8 = 172 mm2. Net area of connected leg = (90 - 21.5) x 8 = 548 mm2. Net area of outstanding leg = 60 x 8 = 480 mm2. Net area of section = 548 + 480 = 1028 mm2. Add shear lag term for the outstanding leg, and hence the net effective area is obtained.
The design of a tension member proceeds in a step-by-step manner. First, the factored design load is determined by applying the appropriate load combinations to the working loads. Second, the required gross area is estimated by dividing the design load by the permissible design strength, and a trial section is chosen from the section tables. Third, the net effective area of the chosen section is computed, allowing for the holes and for shear lag. Fourth, the design strength of the member is calculated using both the gross yielding and net rupture criteria, and the smaller value is compared with the design load. If the design strength is less than the design load, a heavier section is chosen and the process is repeated.
A lug angle is an angle section provided at a connection to reduce the effective length of the connection and to transmit the load more efficiently. When the gusset plate is attached to only one leg of a long angle, the load transfer through the outstanding leg is delayed, and a lug angle helps by picking up the load directly from the outstanding leg. A lug angle is provided when the length of the connection becomes excessive or when the load is very high. The lug angle is connected to the main angle as well as to the gusset plate, and it is designed to carry at least the share of the load corresponding to the outstanding leg.
The efficiency of a tension member is the ratio of the strength of the member to the strength of the solid section of the same material, and it is reduced by the holes and by shear lag. A well-designed tension member should have an efficiency as close to 100 percent as possible, which is achieved by choosing a compact section, by placing the holes so that they are staggered, and by connecting as many elements of the section as possible. Staggered holes, in which the holes in different rows are offset from each other, reduce the loss of area and increase the strength of the section. The net area through a staggered chain is computed by subtracting the holes and adding a term that accounts for the pitch of the stagger.
| Failure Mode | Expression | Partial Safety Factor |
|---|---|---|
| Gross section yielding | Tdg = Ag x fy / gamma_m0 | gamma_m0 = 1.10 |
| Net section rupture | Tdn = 0.9 x An x fu / gamma_m1 | gamma_m1 = 1.25 |
| Block shear | Combination of shear and tension planes | gamma_m0, gamma_m1 |
| Design strength | Min of Tdg, Tdn and block shear | - |
| Section | Use | Relative Efficiency |
|---|---|---|
| Flat bar | Light ties | Good |
| Single angle | Light truss members | Fair |
| Two angles back to back | Truss chords | Good |
| Channel section | Heavier ties | Good |
| Built-up section | Heavy bridge ties | Best |
flowchart TD
A[Tension Members] --> B[Types of sections]
A --> C[Failure modes]
A --> D[Net area and shear lag]
A --> E[Design strength]
A --> F[Slenderness and lug angles]
B --> B1[Flat bars, angles, channels]
B --> B2[Built-up sections]
C --> C1[Yielding of gross section]
C --> C2[Rupture of net section]
C --> C3[Block shear failure]
D --> D1[Net area = gross - holes]
D --> D2[Shear lag effect on angles]
E --> E1[Tdg = Ag x fy / 1.10]
E --> E2[Tdn = 0.9 x An x fu / 1.25]
F --> F1[Max slenderness ratio 400]
F --> F2[Lug angle for efficient load transfer]
The following diagrams show the net section of a tension member and a typical tension member connected to a gusset plate.
Tension members are the simplest structural members to design, because they carry their load in uniform tension without any risk of buckling, and their design reduces to the correct calculation of the net effective area and the design strength. In this chapter we have studied the various sections used as tension members, the two principal failure modes of gross section yielding and net section rupture, the additional block shear failure at the connection, and the effect of shear lag which reduces the effective area of angles and channels. We have seen the design strength expressions of IS 800:2007, with the partial safety factors 1.10 and 1.25, the limiting slenderness ratio of 400, and the use of lug angles for efficient load transfer. The worked example on net effective area showed how the holes and the shear lag are accounted for in practice. The ideas of net area, effective area and design strength that we have developed here are fundamental to the design of truss members, bracing, girders and all the other tension elements of a steel structure, and they will be used again in the chapters on roof trusses and design concepts that follow.