Subject: Civil Engineering Chapter: Steel Structures Topic: 10.5 Compression Members
A compression member is a structural member that carries a load which pushes it along its longitudinal axis, so that the internal forces developed are purely compressive. Columns, struts, top chords of trusses, the compression members of bracing systems and the struts of roof trusses are all examples of compression members. Unlike a tension member, which has no fear of buckling, a compression member may fail by buckling at a stress far below the yield stress of the material, and therefore the design of a compression member is dominated by stability considerations. The load at which a slender compression member suddenly bends sideways and loses its strength is called the critical buckling load, and it depends on the effective length, the moment of inertia and the modulus of elasticity of the member.
The behaviour of a compression member is governed by the slenderness ratio, which is the ratio of the effective length of the member to the radius of gyration of its cross-section. A short and stocky column fails by crushing when the stress reaches the yield stress, whereas a long and slender column fails by buckling at a much lower stress. Between these two extremes, columns fail by a combination of crushing and buckling, and the actual failure stress lies between the Euler buckling stress and the yield stress. In steel design, the permissible compressive stress in a column is expressed as a function of the slenderness ratio, so that the design stress reduces as the member becomes more slender.
In this chapter we will study the types of compression members, the Euler buckling theory and its limitations, the concept of effective length and slenderness ratio, the column curves of IS 800:2007, the design of columns using section tables, the allowable compressive stress in compression, the design of built-up compression members with lacing and battening, and the requirements of lateral stability. We will also solve worked examples on finding the load carrying capacity of a column. The concepts of this chapter, especially effective length and slenderness ratio, are fundamental to the design of columns, trusses and all compression elements in steel structures.
When a short column is loaded axially, it fails by crushing when the compressive stress reaches the yield stress of the material, and the failure is accompanied by bulging of the material. When a long column is loaded, it fails by buckling, in which the member bends sideways at the critical load even though the material has not reached its yield stress. The transition between crushing failure and buckling failure depends on the slenderness ratio of the member. The critical buckling load of an ideal, initially straight, pin ended column was given by the Swiss mathematician Euler as Pe = pi2 E I / Le2, where E is the modulus of elasticity, I is the minimum moment of inertia of the section and Le is the effective length of the column.
The Euler formula assumes a perfectly straight column, a perfectly central load, homogeneous material and pin ended supports, none of which is exactly true in practice. Real columns have initial crookedness, the load may be eccentric, and the material may have residual stresses. Consequently, real columns fail at loads lower than the ideal Euler load, and the failure stress is obtained by dividing the Euler load by the area. The stress corresponding to the Euler buckling load is the Euler buckling stress, and it decreases as the slenderness ratio increases. For very low slenderness ratios, the Euler stress becomes greater than the yield stress, which is not possible, and in that region the column fails by crushing.
To design a real column, the empirical design curve of IS 800:2007 is used. In the limit state method, the design compressive stress fcd is obtained by dividing the column buckling curve value by the partial safety factor gamma_m0 = 1.10, and it is a function of the non-dimensional slenderness ratio lambda, which is the square root of fy divided by the Euler buckling stress. The design compressive strength of the column is then P = fcd x A, where A is the gross area of the section. The column curves of IS 800 give different strength values for different section classes, such as rolled, welded and cold formed sections, because the residual stresses and imperfections differ between them.
The effective length of a compression member is the length between the points of contraflexure, that is, the length of an equivalent pin ended column that has the same buckling load as the actual column. The effective length depends on the degree of end restraint of the column. For a column with both ends pinned, the effective length is equal to the actual length; for both ends fixed, the effective length is half the actual length; for one end fixed and the other free, the effective length is twice the actual length; and for one end fixed and the other pinned, the effective length is 0.7 times the actual length. In frames, the effective length is found by considering the stiffness of the members meeting at the joints.
The slenderness ratio is defined as the ratio of the effective length Le to the least radius of gyration r of the cross-section, that is, lambda = Le / r. The radius of gyration is given by r = square root of (I / A), where I is the moment of inertia and A is the area of the section. For buckling, the least radius of gyration governs, because the column buckles about the axis with the smallest moment of inertia. For columns of equal area, the section with the larger radius of gyration has a higher buckling resistance, which is why wide-flanged sections are preferred over narrow sections for columns.
IS 800:2007 specifies the maximum slenderness ratio for compression members as 180 for members carrying compression due to dead and imposed loads, 250 for members carrying compression due to wind and earthquake loads only, and 350 for members subjected to reversal of stress. These limits ensure that the members are not too slender to handle safely. The design compressive stress fcd reduces as the slenderness ratio increases, and for very slender columns the design stress is governed purely by buckling. The allowable compressive stress for the working stress design of columns is given by the Rankine-Gordon and Euler type formulas, but in the limit state method the column buckling curve is used directly.
A pin ended column of effective length 3 m has an ISMB 200 section with area A = 3083 mm2 and least radius of gyration r = 22.3 mm. If the Euler buckling load formula is applied, estimate the critical buckling load. Take E = 2 x 10^5 N/mm2.
Solution: Least moment of inertia, I = A x r2 = 3083 x (22.3)2 = 1533139 mm4. Euler buckling load, Pe = pi2 E I / Le2 = 9.8696 x 200000 x 1533139 / (3000)2. Pe = 9.8696 x 200000 x 1533139 / 9000000 = 336210 N, about 336 kN. Hence the critical buckling load of the pin ended column is about 336 kN.
The design of an axially loaded column proceeds as follows. First, the factored design load is determined. Second, the required area is estimated by dividing the load by an assumed design compressive stress, and a trial section is chosen. Third, the slenderness ratio of the trial section is computed using the effective length and the least radius of gyration, and the design compressive stress fcd is read from the column curve. Fourth, the design compressive strength is found as fcd x A, and if it is greater than the design load, the section is satisfactory; otherwise a heavier section is tried. The section is also checked for the maximum slenderness ratio limit.
For heavy loads, a single rolled section may not provide the required area and radius of gyration, and built-up columns are used. A built-up column consists of two or more rolled sections connected by lacing or battening, so that they act as a single integral member. The rolled sections are spaced apart to increase the moment of inertia and the radius of gyration about the weak axis, and lacing or battens hold them together and prevent local buckling of the individual sections. Lacing consists of flat bars or angles inclined to the axis of the column, arranged in single lacing, double lacing or diamond lacing patterns, while battens are flat plates placed perpendicular to the axis at intervals along the length.
Lacing and battens are designed to carry the transverse shear which is assumed to act on the column, taken as 2.5 percent of the axial load as per IS 800. The lacing is designed for the compression and tension in the lacing bars, and the battens are designed for the shear and bending moment developed between the two channels. The lacing should be so arranged that the effective length of the individual channel between the lacing connections is small, to prevent local buckling. The spacing between the lacing connections must satisfy the requirement that the slenderness ratio of the individual components between the connections does not exceed the specified limit, which is normally kept less than the slenderness ratio of the whole column.
| End Condition | Effective Length |
|---|---|
| Both ends pinned | L |
| Both ends fixed | L / 2 |
| One end fixed, other free | 2 L |
| One end fixed, other pinned | 0.7 L |
| Type of Member | Maximum Slenderness Ratio |
|---|---|
| Compression member, dead + imposed load | 180 |
| Compression member, wind/earthquake only | 250 |
| Member with reversal of stress | 350 |
| Tension member (no buckling) | 400 |
flowchart TD
A[Compression Members] --> B[Failure modes]
A --> C[Euler theory]
A --> D[Effective length]
A --> E[Design strength]
A --> F[Built-up columns]
B --> B1[Crushing of short columns]
B --> B2[Buckling of long columns]
C --> C1[Pe = pi2 E I / Le2]
C --> C2[Limitations of Euler formula]
D --> D1[End condition factors]
D --> D2[Slenderness ratio = Le / r]
E --> E1[Column curves of IS 800]
E --> E2[fcd x A with gamma_m0 = 1.10]
F --> F1[Lacing bars]
F --> F2[Batten plates]
The following diagrams show the buckling shapes of columns under different end conditions and a built-up column with lacing.
Compression members are fundamentally different from tension members because they are governed by stability and buckling rather than by simple strength. In this chapter we have studied the crushing failure of short columns and the buckling failure of long columns, the Euler critical buckling load and its limitations, the concept of effective length for different end conditions, and the slenderness ratio which links the geometry of the member to its buckling strength. We have seen that IS 800:2007 provides column curves from which the design compressive stress fcd is read for a given non-dimensional slenderness ratio, and that the design strength is fcd times the gross area. We have solved a worked example on the Euler buckling load of a column, and we have examined the design of built-up columns with lacing and battens, which are used when a single rolled section is insufficient. The principles of effective length, slenderness ratio and buckling strength developed in this chapter are applied directly to the design of columns and bases, roof truss struts and every compression element in a steel structure, making this one of the most important chapters in the steel structures syllabus.