1. Introduction

A plate girder is a built-up steel beam made by connecting separate plates and angles by riveting, bolting or welding to form an I-shaped section. Plate girders are used when a single rolled I-beam section is not strong enough to carry the load, such as in highway and railway bridges, industrial gantries, crane girders and large span floors. By building up the section from plates, the designer can make the girder as deep as required, and because the bending strength increases rapidly with depth, a plate girder can be made very efficient for carrying large bending moments. The plate girder is essentially a deep beam in which the flanges resist the bending moment and the web resists the shear force.

The plate girder consists of two flange plates joined to a deep web plate, and angles are often riveted between the flanges and the web to stiffen the joint. The flange plates carry the bending moment, since they are farthest from the neutral axis, and the web carries the shear force, since it is deep and thin. Because the web is thin and deep, it is liable to buckle due to shear and to the compressive stresses near the compression flange, and therefore vertical stiffeners, horizontal stiffeners and bearing stiffeners are provided to keep the web stable. The design of a plate girder therefore involves proportioning the flanges for bending, the web for shear, and the stiffeners for stability.

In this chapter we will study the components of a plate girder, the design of the web and the flanges, the concept of the economical depth of the girder, the shear strength of the web and the phenomenon of tension field action, the design of the different types of stiffeners, and the various checks that must be performed. We will also solve a worked example on the preliminary proportioning of a plate girder. The design of plate girders extends the beam theory of the previous chapter to deep built-up sections and introduces the very important concepts of web buckling and stiffening, which are frequently examined.

2. Components and Preliminary Proportioning

The three main components of a plate girder are the web plate, the flange plates and the stiffeners. The web plate is a thin vertical plate whose depth is the depth of the girder, and its thickness is chosen to resist the shear force without buckling. The flange plates are horizontal plates welded or riveted to the top and bottom of the web, and they carry the bending moment. The stiffeners are flat plates or angles attached to the web to prevent buckling; vertical stiffeners are provided over the supports and at intervals along the span, and horizontal stiffeners are provided near the compression flange for deep girders.

The first step in the design of a plate girder is to fix the overall depth and the web dimensions. The economical depth of a plate girder is that depth at which the total weight of the girder is a minimum, and it is approximately given by d = 1.1 times the cube root of M divided by t, where M is the maximum bending moment and t is the web thickness. For simply supported girders, the depth is usually taken between one-twelfth and one-tenth of the span for highway bridges and somewhat larger for railway bridges. The web thickness should satisfy the minimum requirement for shear and should not be less than the value required to avoid buckling.

Once the depth is fixed, the web thickness is chosen such that the shear stress in the web does not exceed the permissible value. The flanges are then proportioned so that the flange area is sufficient to carry the bending moment, assuming that the moment is resisted mainly by the flanges. The required flange area is approximately M divided by the permissible bending stress times the depth, and the flange plates and angles are selected to provide this area. The moment of inertia of the whole section is then computed accurately, and the section is checked for the maximum bending stress in the extreme fibre.

Worked Example

A plate girder is to be designed for a maximum bending moment of 2000 kNm. If the permissible bending stress is 165 N/mm2 and the overall depth is taken as 1200 mm, estimate the total flange area required.

Solution: Bending moment, M = 2000 kNm = 2000 x 10^6 Nmm. If the moment is resisted mainly by the flanges, the force in each flange is approximately M / d. Force in each flange = 2000 x 10^6 / 1200 = 1666667 N. Required flange area = Force / permissible stress = 1666667 / 165 = 10101 mm2. Hence each flange requires an area of about 10101 mm2, provided by flange plates and angles.

3. Design of Web, Flanges and Economical Depth

The web of a plate girder is designed primarily for shear. The design shear strength of the web is Vd = Av x fy / (root3 x gamma_m0), where Av is the shear area of the web, equal to the depth of the web times its thickness. The web must also satisfy the requirement that it does not buckle under the shear and the compressive stresses. The ratio of the depth to the thickness of the web, d/t, determines whether the web is safe in shear without tension field action, and for values of d/t beyond certain limits, the shear buckling of the web must be checked. The slenderness of the web is limited so that it does not buckle as a compression element near the compression flange.

The flanges are designed to carry the bending moment. Since the flange plates are at the extreme fibres, the maximum bending stress in the flange must not exceed the permissible bending stress. The required flange area is found from the relationship between the bending moment, the depth and the permissible stress, and the flange is built up from flange plates and flange angles. The flange width is chosen to be large enough to provide lateral stability and to support the loads coming onto the flange from the deck, and it must also be sufficient to avoid local buckling of the flange plate. The flange plates may be curtailed towards the ends of the girder, where the bending moment is smaller.

The economical depth of a plate girder is the depth at which the weight of the girder is minimum, and it is obtained by equating the weight of the flanges with the weight of the web, which gives the condition that the flange area is approximately equal to the area of the web. This leads to the approximate formula d = 1.1 (M / t)^(1/3), where M is the maximum bending moment and t is the web thickness. The economical depth is used as a guide, and the actual depth is chosen considering the headroom available, the span and the fabrication requirements. The depth of the girder also affects the deflection, because a deeper girder is stiffer.

4. Stiffeners and Web Stability

The thin web of a plate girder is prone to buckling, and stiffeners are provided to keep the web stable. Vertical stiffeners, also called transverse stiffeners, are provided at intervals along the span to divide the web into panels and to increase its resistance to shear buckling. The maximum spacing of vertical stiffeners is governed by the depth of the web, and they are always provided over the supports, where they act as bearing or load carrying stiffeners to transfer the reaction into the web. Intermediate vertical stiffeners are not designed to carry load but to prevent the web from buckling.

Horizontal stiffeners are provided for deep webs to reduce the effective depth of the web and to prevent buckling of the web near the compression flange. They are placed at a distance of about one-fifth of the depth from the compression flange, and they reduce the slenderness of the web in the compression zone. For very deep girders, both vertical and horizontal stiffeners are provided, and in some cases a second horizontal stiffener is added near the tension flange. The stiffeners are designed so that their moment of inertia is sufficient to act as rigid supports for the web panels.

Bearing stiffeners are provided at points of concentrated loads and reactions, such as the supports, to prevent the web from crippling and to transfer the load into the web over the full depth. They are designed as struts carrying the reaction, and the effective section of the strut includes the stiffener plates plus a part of the web on either side. In addition, the web must be checked for local buckling at the points of concentrated load, a phenomenon called web crippling, and bearing stiffeners are provided where the concentrated loads exceed the web capacity. The stiffeners are placed on both sides of the web wherever possible and are connected by rivets or welds capable of transmitting the load.

5. Quick Revision Tables

Table 1: Components of a Plate Girder and Their Function

Component Position Function
Web plate Centre, vertical Resists shear force
Flange plates Top and bottom Resists bending moment
Vertical stiffeners Along span, over supports Prevent web shear buckling
Horizontal stiffeners Near compression flange Prevent web compression buckling
Bearing stiffeners At supports and loads Transfer reactions into web

Table 2: Typical Depth-to-Span Ratios of Plate Girders

Type of Girder Depth to Span Ratio
Highway bridge girder 1/12 to 1/10
Railway bridge girder 1/12 to 1/8
Industrial gantry girder 1/10 to 1/7
Economical depth criterion 1.1 x (M / t)^(1/3)

6. Mind Map

flowchart TD
    A[Plate Girders] --> B[Components]
    A --> C[Web design]
    A --> D[Flange design]
    A --> E[Economical depth]
    A --> F[Stiffeners]
    B --> B1[Web plate, flange plates, stiffeners]
    C --> C1[Vd = Av fy / (root3 x 1.10)]
    C --> C2[Shear buckling check]
    D --> D1[Flange carries bending moment]
    D --> D2[Flange area = M / (f x d)]
    E --> E1[d = 1.1 (M / t)^(1/3)]
    F --> F1[Vertical stiffeners]
    F --> F2[Horizontal stiffeners]
    F --> F3[Bearing stiffeners]

7. Important Diagrams (SVG)

The following diagrams show the cross-section of a plate girder with its components and the arrangement of stiffeners along the span.

Cross-Section of a Plate Girder Top flange plate Bottom flange plate Web plate thickness tw d Flange angles Flanges resist bending; web resists shear. Golden Rule Flanges carry the bending moment; the thin web carries shear and needs stiffening.

Stiffeners on a Plate Girder Bearing stiffener Bearing stiffener Vertical stiffener Vertical stiffener Horizontal stiffener Stiffeners divide the web into panels and prevent buckling. Bearing stiffeners carry the reaction at supports. Golden Rule Vertical stiffeners prevent shear buckling; horizontal stiffeners prevent compression buckling.

8. Common Mistakes

  1. Many students design the flange area using the permissible stress without allowing for the holes in a riveted girder, which overestimates the strength.
  2. A frequent error is to ignore the web contribution to the bending moment and then check the section with the web included, which is inconsistent.
  3. Some candidates take the depth of the girder as the depth of the web only and forget to include the flange thickness in the overall depth.
  4. Students often forget that the web of a plate girder must be checked for shear buckling when the depth to thickness ratio is large.
  5. A common mistake is to provide horizontal stiffeners instead of vertical stiffeners for shear buckling; vertical stiffeners resist shear buckling.
  6. Many candidates do not check the web for crippling at points of concentrated loads and supports, which is a common cause of failure.
  7. Students forget that the economical depth is that depth at which the weight of flanges equals the weight of the web, and use it blindly.
  8. Some candidates design bearing stiffeners as simple flat plates without considering the effective strut section that includes part of the web.

9. Exam Tips

  1. Remember that the flanges carry the bending moment and the web carries the shear; this division of labour is the key to plate girder design.
  2. Memorise the economical depth formula d = 1.1 x (M / t)^(1/3), where M is the bending moment and t is the web thickness.
  3. Learn the depth to span ratios: 1/12 to 1/10 for highway girders and 1/12 to 1/8 for railway girders.
  4. Note that vertical stiffeners are provided to prevent shear buckling of the web and that bearing stiffeners carry the reactions at the supports.
  5. Remember that the design shear strength of the web is Av x fy / (root3 x gamma_m0), with gamma_m0 = 1.10.
  6. Remember that the horizontal stiffener is placed at about one-fifth of the depth below the compression flange.
  7. Note that a plate girder is used when the required depth or capacity exceeds that of a single rolled section, typically for spans over about 12 to 15 metres.

10. Conclusion

A plate girder is a built-up deep beam that carries large bending moments and shear forces by combining web plates, flange plates and stiffeners into an efficient I-section. In this chapter we have studied the components of a plate girder, the design of the web for shear and the flanges for bending, the concept of the economical depth at which the girder weight is minimum, and the important phenomenon of web buckling. We have examined the three types of stiffeners, namely vertical, horizontal and bearing stiffeners, and their roles in keeping the thin web stable and in carrying the reactions at the supports. We have solved a worked example on the preliminary proportioning of the flanges of a plate girder. The girder design builds directly on the beam theory of the previous chapter and introduces the additional checks of web buckling, web crippling and lateral stability that are essential for deep thin-webbed sections. A candidate who understands the division of labour between the flanges and the web, and the role of stiffeners, will be able to solve plate girder questions confidently and correctly.