🏗️ Civil Engineering

10.8 Roof Trusses

Start MCQ Practice →

10.8 Roof Trusses

Subject: Civil Engineering Chapter: Steel Structures Topic: 10.8 Roof Trusses

1. Introduction

A roof truss is a triangular framework of steel members used to support the roof of a building over large spans without intermediate columns. Trusses are used in factories, warehouses, railway stations, auditoriums, sports halls and hangars, where the span is too large for a beam or where a flat ceiling is not required. The truss is formed by joining straight members at their ends to form a series of triangles, and because a triangle is the only stable geometric shape, a triangular framework does not change its shape when loaded, provided the joints are treated as pin joints. In a properly designed truss, all the members carry either pure tension or pure compression, and there is no bending, which makes the truss an extremely efficient structure.

The top chord of the truss, also called the principal rafter, carries the load from the roof covering, which is transferred through the purlins placed along the top chord. The bottom chord, also called the main tie, carries the tension at the bottom, and the internal web members, called struts and ties, transfer the load between the chords. The two main trusses of a building are connected by longitudinal members called purlins at the top and the bottom chord bracing, and the wind loads are resisted by the bracing systems. For competitive examinations, the important topics are the types of roof trusses, the loads on the truss, the analysis of truss members by the method of joints, and the design of the individual members and connections.

In this chapter we will study the types of roof trusses such as the fan truss, the Fink truss, the Howe truss, the Pratt truss and the Warren truss, the different types of loads that act on a roof truss, the calculation of the wind load, the analysis of the truss by the method of joints, the design of the purlins and the members, and the various types of supports and connections. We will also solve a worked example on the analysis of a simple truss by the method of joints. The concepts of tension members and compression members developed in the earlier chapters are applied directly here to the design of truss members.

2. Types of Roof Trusses

Roof trusses are classified according to the shape of their outline and the arrangement of their web members. The principal types are the north light truss, the saw tooth truss, the fan truss, the Fink truss, the Howe truss, the Pratt truss, the Warren truss and the scissors truss. The Fink truss, also called the Belgian truss, has the bottom chord horizontal and the top chord inclined, with inclined web members, and it is used for spans up to about 12 metres. The fan truss has the web members radiating from a point on the bottom chord like the ribs of a fan, and it is used for spans up to about 15 metres.

The Howe truss has vertical members in compression and inclined members in tension, while the Pratt truss has vertical members in tension and inclined members in compression, and both are used for spans of about 15 to 25 metres where a flat roof is required. The Warren truss, which has only inclined members arranged in a zigzag pattern, is used for spans of about 20 to 60 metres and is very economical. The north light truss is used for factory roofs where natural lighting is required, since one slope is steeper than the other and the steeper slope can be glazed. The choice of the truss type depends on the span, the roof slope, the loads and the architectural requirements.

The members of a truss are connected at their ends by gusset plates, which are flat plates to which the members are riveted, bolted or welded. The joints of a truss are assumed to be frictionless pin joints for the purpose of analysis, which means that only axial forces act in the members and there is no bending moment. The distance between the joints is the effective length of the member for design purposes, and the members are designed as tension or compression members as discussed in the earlier chapters. The truss is supported at its ends on columns or walls, and the supports are usually designed so that one support allows free movement to accommodate thermal expansion.

3. Loads on a Roof Truss

The loads acting on a roof truss are the dead loads, the live loads and the wind loads. The dead load consists of the self weight of the truss, the weight of the roof covering such as AC sheets or GCI sheets, the purlins, the bracing and any suspended ceilings or services. The dead load is computed from the weights per unit area of the various components and the spacing of the trusses. The live load or imposed load accounts for the weight of workmen, equipment and stored materials during construction and maintenance, and IS 875 specifies the minimum live load for roofs, which for an accessible flat roof is about 1.5 kN/m2.

The wind load is the most important and often the governing load for a roof truss, because a sloping roof experiences both pressure and suction due to the wind. The wind load on a roof is calculated as per IS 875 part 3, using the basic wind speed of the location, the height and terrain factors, and the pressure coefficients for the roof. The wind acts normally to the roof surface, and the inclined surfaces may experience either positive pressure on the windward slope and suction on the leeward slope, or suction on both slopes depending on the slope angle. The wind load is the product of the wind pressure coefficient, the design wind pressure and the tributary area.

The dead load, live load and wind load are combined with the appropriate load factors as per IS 800, and the most critical combination is used for the design. The forces in the members are then found by analysing the truss under the factored loads. In addition to these loads, the truss may be subjected to loads due to the self weight of the purlins, the roof sheeting and the bracing, and in industrial buildings the loads from cranes and monorails may also be transmitted to the trusses. The analysis is simplified by treating the loads as acting at the panel points, because the purlins are placed at the panel points and the loads they carry are transmitted to the joints.

4. Analysis of Trusses by the Method of Joints

The analysis of a truss is the calculation of the forces in its members for the given loads, and the two standard methods are the method of joints and the method of sections. In the method of joints, the equilibrium of each joint of the truss is considered in turn, using the two equations of static equilibrium, sum of horizontal forces equal to zero and sum of vertical forces equal to zero. Since only two equations are available at each joint, the method starts at a joint where only two unknown member forces exist, such as a support joint, and proceeds joint by joint until all the forces are known.

The sign convention is that a member which is pulled is in tension and a member which is pushed is in compression. In the force diagram, a member force acting away from the joint indicates tension, and a force acting towards the joint indicates compression. The members of a truss must be classified as tension or compression members because their design is different: a tension member is designed for its net area while a compression member is designed for its slenderness ratio and buckling strength. The top chord and the struts are in compression, while the bottom chord and the ties are in tension, in a simply supported truss under downward loading.

Worked Example

A simply supported roof truss of span 12 m has equal vertical loads of 20 kN at each of the three panel points on the top chord, with the load at the apex and the loads at the two intermediate points. Determine the reactions at the supports.

Solution: Total load on the truss = 3 x 20 = 60 kN. By symmetry, each support reaction = 60 / 2 = 30 kN. The reaction at the left support is 30 kN acting vertically upwards, and the reaction at the right support is also 30 kN. These reactions are then used with the method of joints to find the forces in the members, starting from the support joints.

The purlins are the horizontal members placed along the top chord of the truss, spaced at regular intervals, to support the roof covering and to transfer its weight to the trusses. Purlins are usually channel sections or angle sections, and they act as beams subjected to bending due to the vertical dead and live loads and to the wind load acting normally to the roof. Since the roof is sloping, the purlin is loaded both in the direction perpendicular to the roof and along the roof, and it is designed for biaxial bending. The purlins also provide lateral support to the compression flange of the top chord.

The design of a truss member is carried out as discussed in the chapters on tension and compression members. The top chord is designed as a compression member for the maximum compressive force, using the effective length equal to the distance between the panel points in the plane of the truss and the appropriate value out of the plane of the truss. The bottom chord is designed as a tension member for the maximum tensile force, using the net effective area. The struts and ties are designed similarly, and the slenderness ratios are checked against the limits of IS 800. The connections at the gusset plates are then designed using rivets or welds.

The roof of a steel building also requires purlins, sag rods, bracing and gusset plates. Sag rods are provided between the purlins to reduce their span in the direction down the slope, and they carry the component of the load along the roof. The bracing systems, consisting of the bottom chord bracing and the top chord bracing, transmit the wind loads to the supports and keep the trusses stable. The whole roof structure is designed as a unit so that every load path from the roof covering to the foundation is complete and safe. The truss members are usually made of single or double angles, and the gusset plates are designed to connect all the members meeting at a joint.

5. Quick Revision Tables

Table 1: Types of Roof Trusses and Their Spans

Type of Truss Arrangement Approximate Span
Fink (Belgian) truss Inclined chords, inclined web Up to 12 m
Fan truss Web radiating from bottom chord Up to 15 m
Howe truss Verticals in compression 15 to 25 m
Pratt truss Verticals in tension 15 to 25 m
Warren truss Only inclined members 20 to 60 m

Table 2: Loads on a Roof Truss

Load Type Source Acted By
Dead load Roofing, purlins, self weight Vertical, at panel points
Live load Workmen, maintenance Vertical, at panel points
Wind load Wind pressure (IS 875-3) Normal to roof surface
Snow load Snow accumulation Vertical, on roof

6. Mind Map

flowchart TD
    A[Roof Trusses] --> B[Types of trusses]
    A --> C[Loads on truss]
    A --> D[Analysis methods]
    A --> E[Purlin and member design]
    B --> B1[Fink, fan, Howe, Pratt, Warren]
    C --> C1[Dead, live, wind, snow]
    D --> D1[Method of joints]
    D --> D2[Method of sections]
    E --> E1[Purlins - biaxial bending]
    E --> E2[Top chord compression, bottom chord tension]
    E --> E3[Sag rods and bracing]

7. Important Diagrams (SVG)

The following diagrams show the layout of a typical roof truss and the arrangement of the purlins and roof covering.

Fan Type Roof Truss Top chord (rafter) Bottom chord (tie) Strut (compression) Web (tension) Members carry only axial forces; joints are assumed to be pins. Golden Rule Top chord and struts are in compression; bottom chord and ties are in tension.

Roof Covering and Purlins on a Truss Purlin Purlin AC sheeting AC sheeting Sag rod down the slope Purlins act as beams carrying the roof load to the truss joints. Golden Rule Purlin loads act at panel points; wind load acts normal to the roof surface.

8. Common Mistakes

  1. Many students forget that a truss with pin joints carries only axial forces, and they wrongly apply bending theory to the members.
  2. A frequent error is to combine wind pressure on one slope and suction on the other wrongly; the wind coefficients must be applied with their signs.
  3. Some candidates add the dead, live and wind loads without considering the load combinations and partial safety factors of IS 800.
  4. Students often forget that the live load on a roof may be reduced for slopes, and they use the full flat roof value.
  5. A common mistake is to treat all the web members as struts; some web members are ties and must be designed in tension.
  6. Many candidates forget the sag rods and the bracing in the load path, so their estimates of member forces are incomplete.
  7. Students forget that the purlin is subjected to biaxial bending because it is on a slope, and they design it for uniaxial bending only.
  8. Some candidates do not provide a support that permits thermal movement, leading to the development of unwanted stresses in the truss.

9. Exam Tips

  1. Remember the types of trusses and their spans: Fink up to 12 m, fan up to 15 m, Howe and Pratt 15 to 25 m, Warren 20 to 60 m.
  2. Memorise that the top chord is in compression and the bottom chord is in tension for a simply supported truss under downward load.
  3. Learn the method of joints: start at a joint with only two unknown forces and proceed joint by joint.
  4. Remember that the wind load acts normal to the roof surface and can be both pressure and suction, as per IS 875 part 3.
  5. Note that purlins are designed for biaxial bending, and sag rods reduce their span along the slope.
  6. Remember the load combinations of IS 800, where the dead load, live load and wind load are factored and combined to find the critical case.
  7. Know that the effective length of a truss member is the distance between joints, with different values in and out of the plane of the truss.

10. Conclusion

Roof trusses are the triangular frameworks that economically support the roofs of large span buildings, and their design combines the analysis of pin jointed structures with the design of tension and compression members studied in the earlier chapters. In this chapter we have studied the various types of roof trusses, namely the Fink, fan, Howe, Pratt and Warren trusses, and their typical spans. We have examined the three categories of loads acting on a truss, the dead load, the live load and the wind load, and the manner in which they are combined and applied at the panel points. We have analysed a simple truss to determine the support reactions, and we have studied the design of the purlins, the truss members and the connections at the gusset plates. The bracing systems and sag rods complete the roof structure so that every load finds a safe path to the foundation. A candidate who can identify the members in tension and compression and apply the method of joints correctly will find roof truss questions in the examination straightforward and scoring.