Subject: Civil Engineering Chapter: Steel Structures Topic: 10.9 Columns and Bases
A column is a vertical compression member that supports the floors and roofs of a building and transmits the loads to the foundation. Steel columns are used in framed buildings, industrial sheds, bridge piers and transmission towers, and they are the main vertical load carrying members of a steel structure. The design of a steel column involves choosing a section that can safely carry the axial load without crushing or buckling, and the column is designed as a compression member as discussed in the chapter on compression members, using the effective length, the slenderness ratio and the design compressive stress. The loads from the beams and girders are transmitted to the column through the beam column connections.
The base of a column is the connection between the column and the foundation, and it must transmit the load from the column to the concrete foundation over a sufficiently large area so that the pressure on the concrete does not exceed the safe bearing capacity. The column base consists of a base plate, which spreads the load, and the anchor bolts, which fix the column to the foundation. The base plate is connected to the column shaft by a gusset plate or by welding, and the whole assembly is grouted into the concrete foundation. The design of column bases is an important topic because it completes the load path from the structure to the ground.
In this chapter we will study the types of steel columns, the effective length of columns in frames, the design of axially loaded and eccentrically loaded columns, the different types of column bases, the design of the slab base and the gusset base, the design of base plates and anchor bolts, and the requirements of the foundation. We will also solve a worked example on the design of a slab base. The concepts of compression member design from the earlier chapter are applied here, together with the distribution of bearing pressure on the concrete foundation.
Steel columns may be of several types. The most common is the rolled I-section column, which is efficient for carrying axial load because of its large radius of gyration about both axes. For heavier loads, two channels placed back to back, or a built-up column with lacing and battens, are used. Box columns, formed by welding four plates together, are used where high strength in both directions is required, and tubular columns are used for their high torsional stiffness and clean appearance. The choice of the column section depends on the magnitude of the load, the available space and the architectural requirements.
The effective length of a column in a building frame depends on the degree of restraint provided by the beams and girders connected to it at the top and bottom, and it is calculated by considering the stiffness of the members meeting at the joints. In the elastic frame analysis, the effective length factor is obtained from charts which give the value of the effective length factor for the ratio of the stiffnesses of the columns and beams. For a simple structure, the effective length can be taken as the height of the storey, while for a column fixed at both ends it is half the height. The effective length is multiplied by the actual length to get the effective length used in the slenderness ratio.
The slenderness ratio of a column is the ratio of its effective length to its least radius of gyration, and it must not exceed the maximum value of 180 for compression members under dead and imposed loads. A column is designed by assuming a trial section, computing the slenderness ratio, reading the design compressive stress from the column curves, and checking that the design strength is greater than the design load. If the column is subjected to bending as well as axial load, it is designed as an eccentric column using the interaction formula, which combines the axial stress ratio and the bending stress ratio.
The design strength of an axially loaded column is P = fcd x A, where fcd is the design compressive stress obtained from the column buckling curves of IS 800 for the given slenderness ratio and the section class, and A is the gross area of the section. The design compressive stress fcd is calculated as the yield stress divided by gamma_m0 = 1.10, reduced by a factor which depends on the non-dimensional slenderness ratio. The section is chosen so that the design strength is at least equal to the factored axial load, and the slenderness ratio is within the prescribed limit.
When a column carries an eccentric load, or when the column is part of a rigid frame subjected to moments, the column is subjected to combined axial load and bending. Such a column is designed using the interaction relationship for beam columns, which requires that the ratio of the axial load to the axial load capacity, plus the ratio of the bending moment to the moment capacity, is less than a limiting value. The additional moment due to the axial load acting at the eccentricity, and the secondary moment due to the deflection of the column, are both taken into account. The interaction formula of IS 800 is used with the appropriate equivalent uniform moment factors.
The members of a portal frame, such as a gantry column carrying both the vertical load of the crane and the horizontal thrust, are classic examples of eccentrically loaded columns. In such columns, the compression flange of the column acts like the compression flange of a beam, and the column must be checked for the combined axial stress and bending stress. The gantry girder itself is designed as a beam with the vertical loads and the horizontal surge loads, and the column supporting it must resist both the vertical reaction and the longitudinal and transverse forces from the crane.
A column of effective length 4 m carries a factored axial load of 800 kN. A trial section ISMB 300 has gross area A = 5626 mm2 and least radius of gyration r = 33.5 mm. Estimate the slenderness ratio and the design compressive stress if the column curve gives fcd = 145 N/mm2 for this slenderness ratio.
Solution: Slenderness ratio, lambda = Le / r = 4000 / 33.5 = 119.4. Design compressive strength = fcd x A = 145 x 5626 = 815770 N = 815.8 kN. Since 815.8 kN is greater than the design load of 800 kN, the section ISMB 300 is satisfactory.
The base of a steel column transmits the column load to the foundation, and it is designed so that the bearing pressure on the concrete foundation does not exceed the safe bearing capacity of concrete, which is taken as 0.45 times the characteristic strength of concrete for the design of bases. The column base may be of three types. The slab base is used for columns carrying moderate loads, and it consists of a single base plate welded or connected to the bottom of the column shaft. The gusset base is used for columns carrying heavy loads, and it consists of a base plate stiffened by gusset plates and angles. The grillage base is used for very heavy loads, and it consists of a series of steel beams placed in layers to spread the load over a large area of soil.
The base plate of a slab base is designed by considering the column load distributed uniformly over the base plate, with the plate acting as a cantilever projecting beyond the column section. The thickness of the base plate is calculated from the bending moment developed in the projecting part of the plate, using the formula which relates the thickness to the bearing pressure, the projection of the plate beyond the column and the yield stress of the plate. The area of the base plate is found by dividing the column load by the permissible bearing pressure on the concrete, and the dimensions of the plate are chosen to provide this area while keeping the projections reasonable.
The gusset base is used when the column load is so large that a simple slab base would be too thick. In a gusset base, the column load is transmitted to the base plate through gusset plates and angles, and the base plate is designed for the bearing pressure and the bending caused by the reaction. The gusset plates are designed as cantilevers carrying the load, and they are connected to the column and to the base plate by rivets or welds. The whole assembly is embedded in concrete with the anchor bolts, which prevent the column from being displaced or overturned.
Anchor bolts are provided to fix the column base to the foundation and to resist any uplift or horizontal forces acting on the column. The anchor bolts are embedded in the concrete foundation and pass through holes in the base plate, and they are tightened with nuts after the grout has hardened. The number and size of the anchor bolts depend on the magnitude of the uplift and the horizontal forces, and they are designed so that the tensile stress in the bolts and the bearing on the grout and concrete are within the permissible limits. The base plate is provided with a clearance hole for each anchor bolt, and the hole is large enough to allow for the erection tolerance.
The foundation of a steel column is a concrete footing or a pile cap that receives the base plate and spreads the column load to the soil. The column load is transmitted to the concrete through the base plate, and the grout under the base plate ensures full contact. The design of the foundation is based on the safe bearing capacity of the soil and the permissible settlement, and the footing is proportioned so that the soil pressure is within the allowable value. For heavily loaded columns, the base plate is set on a concrete block of suitable size, and the anchor bolts are placed symmetrically so that the joint remains stable under all loading conditions.
The column base must also be designed for the moment at the base when the column is part of a rigid frame. In such cases, the base is designed as a moment base, and the anchor bolts are provided on both sides of the column to resist the tension due to the moment, while the concrete under the compression side resists the compression. The base plate is made larger and thicker, and the gusset plates transmit the moment to the base plate and the bolts. The complete design of the base ensures that the load, the moment and the horizontal forces are all safely transferred to the foundation.
| Type of Base | Used For | Load Transfer |
|---|---|---|
| Slab base | Moderate loads | Base plate to concrete |
| Gusset base | Heavy loads | Through gusset plates and angles |
| Grillage base | Very heavy loads | Layers of steel beams |
| Moment base | Rigid frames | Bolts resist tension, concrete compression |
| Quantity | Expression / Value |
|---|---|
| Area of base plate | Column load / bearing pressure |
| Safe bearing pressure on concrete | 0.45 x fck |
| Maximum slenderness ratio (column) | 180 |
| Design compressive stress | fcd from column curves |
| Design strength of column | fcd x A |
flowchart TD
A[Columns and Bases] --> B[Types of columns]
A --> C[Effective length]
A --> D[Column design]
A --> E[Column bases]
B --> B1[I-section, built-up, box, tubular]
C --> C1[End condition factors]
C --> C2[Slenderness ratio = Le / r]
D --> D1[Axial columns - fcd x A]
D --> D2[Eccentric columns - interaction formula]
E --> E1[Slab base, gusset base, grillage base]
E --> E2[Base plate and anchor bolts]
The following diagrams show the arrangement of a slab base and a gusset base for a steel column.
Columns and bases complete the vertical load path of a steel structure, carrying the loads from the floors and roofs down to the foundation. In this chapter we have studied the types of steel columns, the effective length of columns in frames, and the design of axially loaded columns using the design compressive stress from the column curves of IS 800. We have examined the design of eccentrically loaded columns using the interaction formula, which is essential for columns in rigid frames and for gantry columns. We have studied the three types of column bases, namely the slab base, the gusset base and the grillage base, the design of the base plate for bearing pressure and bending, and the role of the anchor bolts in resisting uplift and horizontal forces. We have solved a worked example on the adequacy of a column section, and we have seen that the whole assembly of the column, the base plate and the foundation must act together to transmit the loads safely. A candidate who understands the behaviour of columns under axial and eccentric load, and the distribution of pressure under the base, will be able to solve the questions on columns and bases confidently.
A clear understanding of columns and bases is essential because they form the structural link between the superstructure and the substructure. In this chapter we have studied the types of columns, the effective length and slenderness concepts, the design of axially and eccentrically loaded columns, and the three types of column bases with the design of base plates and anchor bolts. The worked example demonstrated how a trial section is checked against the design load using the design compressive stress. The interaction between the axial load and the bending moment in eccentric columns, and the safe transfer of the bearing pressure to the concrete, are the two ideas that every candidate must remember. Mastery of the column design formulas and the base plate design rules will directly translate into marks in the examination, because questions on columns and bases are among the most frequently asked in the steel structures section of civil engineering papers.