Subject: Civil Engineering Chapter: Steel Structures Topic: 10.10 Steel Structure Design Concepts
The design of a steel structure is not merely the application of a set of formulas; it is a systematic process in which the loads are estimated, the forces in the members are determined, the sections are proportioned and the whole structure is checked for safety and serviceability. The design must ensure that the structure is safe against all possible loads, that it does not deflect or vibrate excessively under working loads, and that it is economical and practical to fabricate and erect. In modern practice, the design of steel structures is carried out by the limit state method, which was introduced in the revised version of IS 800 in 2007, and it has replaced the older working stress method for most design work.
The limit state method is based on the concept that a structure must be checked for two categories of limit states: the limit state of strength, which ensures that the structure can carry the maximum loads without collapse, and the limit state of serviceability, which ensures that the structure remains comfortable and functional under normal working loads. For the limit state of strength, the loads are multiplied by partial safety factors to obtain the factored design loads, and the strength of the members is reduced by partial safety factors for the material. For the limit state of serviceability, the working loads are used directly and the deflection, vibration and durability are checked.
In this chapter we will study the design philosophy and the load combinations of the limit state method, the partial safety factors for loads and materials, the concept of factored loads and design strength, the working stress method and its load factor, the differences between the two methods, the analysis of steel frames, the member design philosophy, and the serviceability checks. We will also look at the design of simple steel structures such as trusses, beams and columns as a whole, and at the overall stability of the structure. This chapter ties together all the earlier chapters of the steel structures syllabus into a single coherent design philosophy.
The loads that act on a steel structure are classified as dead loads, imposed or live loads, wind loads, snow loads, earthquake loads and, for special structures, loads due to temperature, erection and dynamic effects. The dead load is the self weight of the structure and all the permanent attachments, the live load is the weight of the movable objects and the users, and the wind load is the pressure exerted by the wind on the exposed surfaces. In India, the dead and live loads are specified in IS 875 part 1 and part 2, the wind load in IS 875 part 3, and the earthquake load in IS 1893. The loads are estimated for the most critical combinations that the structure may experience.
In the limit state method, the design loads are the factored loads, which are obtained by multiplying the characteristic loads by the partial safety factors for loads, gamma_f. The partial safety factors for loads depend on the load combination: for a combination of dead and live loads, both are multiplied by 1.5; for a combination of dead and wind or earthquake loads, the dead load is multiplied by 1.5 or 0.9, whichever is critical, and the wind load by 1.5; and for the combination of dead, live and wind together, the factors are 1.2 for all three. The structure is designed for the combination that produces the most severe effect in each member.
The characteristic strength of the material is the specified yield or ultimate strength, and in the limit state method the design strength is obtained by dividing the characteristic strength by the partial safety factors for the material, gamma_m. The partial safety factor for the material is gamma_m0 = 1.10 for yielding and buckling, gamma_m1 = 1.25 for ultimate failure such as rupture and tension fracture, and gamma_mw = 1.25 for the strength of welds. These factors account for the variation in material properties, the inaccuracies in the analysis, and the consequences of failure. The design is safe if the design strength is at least equal to the design load.
The working stress method was the traditional method of design, in which the structure is designed so that the maximum stress under the working loads does not exceed the permissible stress, which is the yield stress divided by a factor of safety. The factor of safety, typically taken as 1.67 or 1.85 for steel, was applied as a single overall factor, and it did not distinguish between the uncertainties in the loads and the uncertainties in the material properties. The design was checked with the formula that the actual stress is less than or equal to the permissible stress, and the method was simple but conservative and did not give a uniform margin of safety.
The limit state method, on the other hand, applies separate partial safety factors to the loads and to the material, and it considers the actual limit states of collapse and serviceability. The factored design load is compared with the design strength, and the design is based on the actual strength properties of the material rather than on a single permissible stress. The limit state method also explicitly considers the serviceability requirements of deflection, cracking and vibration, which the working stress method treated less rigorously. The limit state method gives a more rational and economical design because it accounts for the actual uncertainties in each parameter.
The relationship between the two methods can be understood from the overall factor of safety. In the working stress method, the permissible stress is fy divided by the factor of safety, while in the limit state method, the design strength is fy divided by gamma_m0, and the load is multiplied by gamma_f. The overall factor of safety in the limit state method is roughly the product of the load factor and the material factor, which is about 1.5 x 1.10 = 1.65, close to the working stress factor of safety. The limit state method is the recommended method of IS 800:2007, although the working stress method is still permitted for certain structures and for the design of foundations.
The analysis of a steel frame begins with the idealization of the structure, in which the members are represented by their centre lines, the joints are idealized as pins or rigid connections, and the supports are idealized as fixed, pinned or roller supports. The frame is then analysed for the critical load combinations to determine the bending moments, shear forces and axial forces in all the members. The analysis may be carried out by the approximate methods of portal and cantilever methods for simple frames, or by the exact methods of slope deflection, moment distribution and the stiffness method for complex frames. The forces obtained from the analysis are then used for the design of the individual members.
The stability of a steel frame must be checked for two aspects: the local stability of the individual members, such as the lateral torsional buckling of beams and the buckling of columns, and the overall stability of the frame as a whole, which may fail by sidesway, that is, the lateral displacement of the frame under lateral loads. The overall stability is ensured by the stiffness of the connections and by the bracing systems. Braced frames are provided with diagonal bracing or shear walls which carry the lateral loads, while unbraced frames rely on the rigidity of the beam column connections to resist sway. The design must also ensure that the frame does not overturn under the action of wind and earthquake loads.
The members of a steel frame are designed according to the type of force they carry. The beams are designed for bending and shear, the columns for axial load and bending, the truss members for tension and compression, and the connections for the forces at the joints. The design of every member follows the same logic: compute the design forces, choose a trial section, check the strength and the stability, and refine the section until all the checks are satisfied. The design of the connections must be consistent with the assumptions of the analysis, so that a joint assumed to be pinned in the analysis is provided with a connection capable of allowing rotation without developing significant moment.
| Load Combination | Dead Load | Live Load | Wind / Earthquake |
|---|---|---|---|
| DL + LL | 1.5 | 1.5 | - |
| DL + WL / EL | 1.5 or 0.9 | - | 1.5 |
| DL + LL + WL | 1.2 | 1.2 | 1.2 |
| Limit State | Partial Safety Factor |
|---|---|
| Yielding and buckling | gamma_m0 = 1.10 |
| Rupture / tension fracture | gamma_m1 = 1.25 |
| Strength of welds | gamma_mw = 1.25 |
| Slip resistance of bolts | gamma_mf = 1.25 |
flowchart TD
A[Steel Structure Design Concepts] --> B[Design process]
A --> C[Loads]
A --> D[Limit state method]
A --> E[Working stress method]
A --> F[Frame analysis and stability]
B --> B1[Loads, analysis, member design, checks]
C --> C1[Dead, live, wind, earthquake]
C --> C2[IS 875 and IS 1893]
D --> D1[Strength limit state]
D --> D2[Serviceability limit state]
D --> D3[Partial safety factors]
E --> E1[Permissible stress = fy / FOS]
E --> E2[Single factor of safety]
F --> F1[Braced and unbraced frames]
F --> F2[Sidesway and overturning]
The following diagrams show the design process of a steel structure and the load transfer path through a braced frame.
The design of a steel structure is a complete process that begins with the estimation of the loads and ends with the safe and economical proportioning of every member and connection. In this chapter we have studied the classification of loads, the load combinations and the partial safety factors of the limit state method, and the philosophy of checking both the limit state of strength and the limit state of serviceability. We have compared the limit state method with the older working stress method, and we have seen how the analysis of steel frames is carried out and how the overall stability of the frame is ensured by bracing and by the rigidity of the connections. The design process follows a clear sequence of load estimation, structural analysis, member design and verification, and every member is designed by ensuring that its design strength equals or exceeds the factored design load. All the topics of the earlier chapters, the properties of steel, the connections, the tension and compression members, the beams, the plate girders, the roof trusses and the columns with their bases, come together in this chapter to form the single unified design methodology of IS 800:2007. A candidate who understands this design philosophy will be able to attempt the integrated design questions of the examination with confidence and will have mastered the entire steel structures portion of the civil engineering syllabus.