Subject: Civil Engineering Chapter: Structural Analysis Topic: 4.1 Types of Structures
Structural analysis is the branch of civil engineering that deals with the determination of the behaviour of structures under the action of applied loads. Every structure, whether a building, a bridge, a dam, a retaining wall or a tower, must be designed to carry its own weight, the weight of the occupants and the effects of wind, earthquake and other environmental forces. Before a single bar of reinforcement is placed or a single member is fabricated, the engineer must first decide what kind of structure is being dealt with, because this decision governs every calculation that follows. For competitive examinations such as SSC JE, RRB JE, GATE and state-level AE/JE exams, the classification of structures is a favourite one-mark topic that tests the basic understanding of a candidate.
A structure can be broadly defined as an assembly of members arranged in such a way that they can safely transfer the applied loads to the supports and, through the supports, to the ground. The members that make up a structure may be bars, beams, columns, cables or plates, and they may be connected to each other by hinges, welds, bolts or rivets. Depending on how the members are joined and how they are supported, a structure may be classified as a beam, a truss, a frame, an arch or a cable structure. Each of these types has its own method of analysis and its own characteristic behaviour under load, and the examiner expects the candidate to recognise the type quickly from a simple sketch.
In this chapter we will study the fundamental classification of structures. We will understand the difference between linear and surface structures, between beams, trusses, frames, arches and cables, and between statically determinate and indeterminate structures. We will also introduce the concepts of rigid joints and pin joints, which control how internal forces develop in the members. This knowledge forms the essential groundwork for the rest of the structural analysis syllabus, because the correct choice of the method of analysis depends entirely on the correct identification of the type of structure.
Structures may be classified into two broad groups on the basis of their geometrical shape: linear structures and surface structures. A linear structure is one in which one dimension is very large compared with the other two, so that it can be idealised as a line. Beams, columns, trusses and frames are linear structures. A surface structure is one in which two dimensions are very large compared with the third dimension, so that it behaves as a two-dimensional surface. Slabs, plates, shells and folded plates are surface structures. Shells and domes are highly efficient because their curved shapes transmit loads mainly through membrane stresses.
A beam is a horizontal member that carries transverse loads and develops bending moment and shear force. A column is a vertical compression member that carries axial load. A truss is a framework of straight members joined only at their ends by hinges, in which every member carries only axial tension or compression, so that the truss bends as a whole but the individual members do not. A frame, in contrast, is a structure in which the members are rigidly connected at their joints, so that bending moments are transmitted through the joints and the members develop bending as well as axial forces. An arch is a curved structure in which the loads are transmitted mainly through axial thrust. Cables and suspension structures carry loads in pure tension.
Consider the following solved example.
Example 1: A structural member carries only axial tension and the joint connections are pin type. Identify the type of structure.
Solution: Since the members are connected by pins and carry only axial forces, the structure is a pin-jointed truss. In a truss, no bending moment develops in the members, and the analysis is carried out by the method of joints or the method of sections.
A beam is the simplest type of structural member used to carry transverse loads. The loads acting on a beam produce internal shear forces and bending moments, and the beam must be proportioned to resist these internal actions. Beams may be simply supported, fixed, cantilever, continuous or overhanging, depending on the type of support. A simply supported beam rests on supports at its two ends and is free to rotate and deflect; a fixed beam is rigidly built into the supports at both ends; a cantilever beam is fixed at one end and free at the other; a continuous beam spans over more than two supports; and an overhanging beam projects beyond its support.
A portal frame is a structure made of columns and a beam rigidly connected to each other. The rigidity of the joints is the most important characteristic of a frame, because it allows bending moments to be transferred from one member to another. When a horizontal load acts on a portal frame, the frame resists it by a combination of bending of the columns and the beam, and this behaviour is fundamentally different from the behaviour of a pin-jointed truss, where the same load would be resisted only by axial forces. Frames are analysed by the slope-deflection method, moment distribution method, and matrix methods, whereas trusses are analysed by joint and section methods.
Let us verify the effect of support conditions with a numerical example.
Example 2: A simply supported beam of span 6 m carries a point load of 30 kN at mid-span. Compute the reactions.
Solution: Total load = 30 kN. By symmetry, the reactions are equal. R(A) = R(B) = 30/2 = 15 kN. The maximum bending moment occurs at the load point and equals (W L)/4 = (30 x 6)/4 = 45 kN-m. Thus the support reactions are 15 kN each and the maximum bending moment is 45 kN-m.
A statically determinate structure is one in which all the reactions and internal forces can be found by using only the equations of static equilibrium, that is, sum of horizontal forces, sum of vertical forces and sum of moments equal to zero. For a planar structure three independent equilibrium equations are available. A simply supported beam, a cantilever beam and a simple pin-jointed truss are examples of statically determinate structures. Their analysis is simple and the results do not depend on the size of the members or the material of which they are made.
A statically indeterminate structure has more unknown reactions or internal forces than the number of independent equilibrium equations available. The excess is called the degree of indeterminacy. Such structures cannot be analysed by equilibrium alone; additional equations must be written from the conditions of compatibility of displacements, which relate the deformations of the members. Fixed beams, continuous beams, portal frames and most real-world building frames are indeterminate. The degree of static indeterminacy for a beam is the number of unknown reactions minus the number of available equilibrium equations.
Example 3: A fixed beam carries a central point load. Find the degree of static indeterminacy.
Solution: A fixed beam has six unknown reactions at the two fixed ends, but for a planar beam only three equilibrium equations are available. Hence the degree of indeterminacy = 6 - 3 = 3. Equivalently, for a fixed-fixed beam of span L under a central load W, the fixed end moments are each W L/8, and the reactions are W/2 each.
| Type of structure | Nature of internal forces | Joint type | Example |
|---|---|---|---|
| Beam | Bending moment and shear force | Support determines type | Simply supported beam |
| Column | Axial compression | Top usually free or hinged | Building column |
| Truss | Pure axial tension or compression | Pin joint | Roof truss, bridge truss |
| Frame | Bending plus axial forces | Rigid joint | Portal frame |
| Arch | Mainly axial thrust with small bending | Hinges at supports/crown | Three-hinged arch |
| Cable | Pure tension | End anchors | Suspension bridge cable |
| Feature | Statically determinate | Statically indeterminate |
|---|---|---|
| Equilibrium equations | Sufficient for solution | Insufficient |
| Degree of redundancy | Zero | One or more |
| Analysis method | Equilibrium only | Compatibility plus equilibrium |
| Effect of member stiffness | No effect on forces | Directly affects forces |
| Deflection | Larger for same section | Smaller for same section |
| Example | Simply supported beam | Fixed beam |
flowchart TD
A[Types of Structures] --> B[Linear structures]
A --> C[Surface structures]
A --> D[Classification by function]
B --> B1[Beam]
B --> B2[Column]
B --> B3[Truss]
B --> B4[Frame]
D --> D1[Determinate]
D --> D2[Indeterminate]
B1 --> B1a[Bending + shear]
B2 --> B2a[Axial compression]
B3 --> B3a[Axial forces only]
B3 --> B3b[Pin joints]
B4 --> B4a[Axial + bending]
B4 --> B4b[Rigid joints]
D1 --> D1a[Solve by equilibrium]
D2 --> D2a[Compatibility equations needed]
The following diagrams show the basic types of linear structures and the difference between determinate and indeterminate supports.
The classification of structures is the first and most important step in structural analysis, because the entire procedure of analysis is dictated by the type of structure being considered. In this chapter we have seen that structures may be classified as linear or surface structures, and that beams, columns, trusses, frames, arches and cables each have a distinct structural behaviour. We have understood that the pin joint of a truss transmits no moment while the rigid joint of a frame transmits full moment, and we have learned how to distinguish determinate structures, which can be solved by equilibrium alone, from indeterminate structures, which require compatibility conditions. Every subsequent chapter, whether it deals with the analysis of beams, trusses, frames or arches, will rely on these fundamental ideas. A candidate who can quickly classify a structure and correctly count its supports and joints will find every later problem much easier, because the type of structure directly tells us which method of analysis to use and how many equations must be written.