🏗️ Civil Engineering

4.5 Analysis of Frames

Start MCQ Practice →

4.5 Analysis of Frames

Subject: Civil Engineering Chapter: Structural Analysis Topic: 4.5 Analysis of Frames

1. Introduction

A frame is a structure in which the members are rigidly connected at their joints, so that the joints rotate as a unit and bending moments are transmitted from one member to another. Unlike a truss, where the joints are pins and the members carry only axial force, the rigid joints of a frame cause every member to carry bending moment, shear force and axial force simultaneously. Portal frames, multistorey building frames and bridge portal frames are the most important examples, and they are analysed by methods that recognise the continuity of the structure at the rigid joints. In competitive examinations, frame analysis is a significant topic, and questions on sway, rigid joints and the degree of indeterminacy of frames appear regularly.

The analysis of a frame is more involved than the analysis of a truss because the number of unknown internal actions is much larger. The behaviour of a frame depends on the relative stiffness of the members, because a rigid joint distributes the applied moments among the members in proportion to their stiffness. This is the reason why the analysis of an indeterminate frame requires methods such as the slope-deflection method, the moment distribution method or the stiffness (matrix) method, which take account of both equilibrium and compatibility of deformations.

In this chapter we will study the classification of frames, the concepts of rigid joints, sway and the degree of indeterminacy of frames, and the simple methods of analysing determinate and indeterminate frames. We will understand how the fixed end moments are distributed among the members at a joint, and we will work through numerical examples using the moment distribution method for a portal frame and the slope-deflection method for a continuous frame. These methods form the essential toolkit for the analysis of real building frames.

2. Types of Frames and Degree of Indeterminacy

Frames are classified as determinate or indeterminate, and as sway or non-sway frames. A sway frame is one in which the joints are free to move laterally, so that a horizontal load causes the whole frame to displace sideways; a non-sway frame is prevented from lateral movement either by its own symmetry or by external bracing. A portal frame with hinged or fixed bases is the classic sway frame, because a horizontal load at the beam level pushes the columns sideways. The analysis of a sway frame requires the consideration of the lateral displacement, which introduces an extra unknown and makes the problem more difficult.

The degree of static indeterminacy of a frame is found by counting the unknown reactions and the internal forces at the joints and subtracting the number of equilibrium equations. For a plane frame, each member contributes three internal forces, and the fixed and pinned ends add reactions. The degree of indeterminacy of a portal frame is three if both bases are fixed, and one if both bases are hinged. These values are often asked directly in one-mark questions, and they determine the type of analysis method that can be used.

Example 1: Find the degree of static indeterminacy of a portal frame with both column bases hinged.

Solution: A plane portal frame has three members. Each hinged base gives two reaction components, so total reactions = 4. Number of equilibrium equations for the whole frame = 3. Internal indeterminacy: the frame has 3 members and 4 joints. Degree of indeterminacy = 4 - 3 = 1. Hence the hinged portal frame is statically indeterminate to the first degree.

3. Moment Distribution Method

The moment distribution method, developed by Professor Hardy Cross, is a systematic iterative procedure for the analysis of indeterminate frames and continuous beams. The method starts by locking all the joints so that they cannot rotate, and computing the fixed end moments for each member under the applied loads. Then one joint is released at a time, and the unbalanced moment at that joint is distributed among the members meeting at the joint in proportion to their stiffness. The distributed moment carried over to the far end of each member is half of the distributed value, and the process is repeated until the unbalanced moments become negligible.

The distribution factor of a member at a joint equals the stiffness of that member divided by the sum of the stiffnesses of all members meeting at the joint. For a prismatic member of length L with the far end fixed, the stiffness is 4 E I/L, and with the far end pinned it is 3 E I/L. The carry-over factor is one half from the fixed end to the other fixed end, and zero from a pinned end. The final moments at the ends of the members are obtained by summing the fixed end moments and all the distributed and carried-over values.

Example 2: Two members meet at a joint. Member AB has a stiffness of 4 E I/L and member BC has a stiffness of 2 E I/L. The fixed end moments are 60 kN-m at the joint side of AB and 40 kN-m at the joint side of BC. Find the final moments using the moment distribution method.

Solution: Total stiffness at the joint = 4 + 2 = 6 units. Distribution factor for AB = 4/6 = 0.667, and for BC = 2/6 = 0.333. Unbalanced moment at the joint = 60 - 40 = 20 kN-m. Distributed to AB = 0.667 x 20 = 13.33 kN-m, and to BC = 0.333 x 20 = 6.67 kN-m. Final moment at AB end = 60 - 13.33 = 46.67 kN-m, and at BC end = 40 + 6.67 = 46.67 kN-m. Hence the joint balances at 46.67 kN-m.

4. Slope Deflection Method

The slope-deflection method is an analytical method in which the end moments of the members of a frame are expressed in terms of the joint rotations and the joint displacements. For a member AB of length L with flexural rigidity EI, the end moments are given by the slope-deflection equations: M(AB) = 2 E I/L x (2 theta-A + theta-B - 3 delta/L) + FEM(AB), and M(BA) = 2 E I/L x (theta-A + 2 theta-B - 3 delta/L) + FEM(BA), where theta-A and theta-B are the joint rotations, delta is the relative lateral displacement of the ends, and FEM are the fixed end moments. The unknowns theta and delta are found by applying the joint equilibrium conditions and the overall equilibrium of the frame.

For a frame without sway, the relative displacement delta is zero, and only the joint rotations are the unknowns. For a sway frame, the lateral displacement delta is an additional unknown, and the extra equation comes from the equilibrium of the horizontal forces. The slope-deflection method is exact, unlike the moment distribution method which is iterative, but it becomes tedious for frames with many joints. In examinations, frames with only a few joints are set, so the slope-deflection method is a very practical tool.

Example 3: For a member of a frame with both ends fixed, E I/L = 1000 kN-m, theta-A = 0.002 radians, theta-B = -0.001 radians, no sway, and no fixed end moments. Compute the end moments.

Solution: M(AB) = 2 E I/L x (2 theta-A + theta-B) = 2 x 1000 x (2 x 0.002 - 0.001) = 2000 x (0.004 - 0.001) = 2000 x 0.003 = 6 kN-m. M(BA) = 2 x 1000 x (theta-A + 2 theta-B) = 2000 x (0.002 - 0.002) = 0 kN-m. Hence M(AB) = 6 kN-m and M(BA) = 0 kN-m.

5. Quick Revision Tables

Table 1: Distribution Factors and Stiffness

Member end condition Stiffness Distribution factor at joint Carry-over factor
Far end fixed 4 E I/L k/sum of k 1/2
Far end pinned 3 E I/L k/sum of k 0
Sway member 6 E I/L for shear - -
Both ends fixed 4 E I/L k/sum of k 1/2

Table 2: Frame Types and Indeterminacy

Frame type Base condition Degree of indeterminacy Analysis method
Portal frame Both bases fixed 3 Moment distribution
Portal frame Both bases hinged 1 Slope deflection
Portal frame One fixed, one hinged 2 Moment distribution
Single bay multistorey Fixed bases 3 x number of stories Matrix method
Gable frame Hinged bases 1 (with symmetry 0) Slope deflection

6. Mind Map

flowchart TD
    A[Analysis of Frames] --> B[Rigid joints]
    A --> C[Sway frames]
    A --> D[Moment distribution]
    A --> E[Slope deflection]
    B --> B1[Rotation continuity]
    B --> B2[Moment transfer]
    C --> C1[Lateral displacement]
    C --> C2[Extra equilibrium equation]
    D --> D1[Fixed end moments]
    D --> D2[Distribution factors]
    D --> D3[Carry-over]
    E --> E1[M = 2EI/L(2 theta + ...)]
    E --> E2[Joint equilibrium]
    E --> E3[No sway: delta = 0]

7. Important Diagrams (SVG)

The following diagrams show a portal frame with its members and the distribution of moments at a rigid joint, and the slope-deflection variables for a typical frame member.

Portal Frame with Rigid Joints Fixed base Fixed base Rigid joint B Rigid joint C Horizontal load H Rigid joints rotate together Moments are transferred through joints Columns resist bending and axial force Sway: horizontal load pushes the frame sideways Golden Rule At a rigid joint the sum of the end moments of all members is zero.

Slope Deflection Variables of a Member theta-A theta-B A B delta M(AB) = 2EI/L (2 theta-A + theta-B - 3 delta/L) + FEM(AB) M(BA) = 2EI/L (theta-A + 2 theta-B - 3 delta/L) + FEM(BA) For non-sway frames, delta = 0 and only joint rotations are unknown. Golden Rule The slope-deflection equation links end moments to joint rotations and sway.

8. Common Mistakes

  1. Students often treat frame joints as pin joints and ignore the moment transfer, which completely changes the frame behaviour.
  2. A frequent error is to use a carry-over factor of one half from a pinned end; the carry-over to a pinned end is zero.
  3. Some candidates forget to compute the distribution factors with the correct stiffness values, using 3 E I/L instead of 4 E I/L for a member with a fixed far end.
  4. Many students ignore the sway of the frame and analyse a sway frame as a non-sway frame, giving incorrect results.
  5. A common mistake is to balance the joint moments without using the carry-over factor, so the far end moments are wrong.
  6. Candidates often forget to apply the joint equilibrium condition that the algebraic sum of the end moments at a joint is zero.
  7. Some students apply the slope-deflection equation without the fixed end moments, omitting the load terms completely.
  8. Another recurring error is to count the degree of indeterminacy of a hinged portal frame as three instead of one, confusing it with a fixed portal frame.

9. Exam Tips

  1. Memorise the stiffness values: 4 E I/L for a fixed far end and 3 E I/L for a pinned far end, because distribution factors depend directly on them.
  2. Remember that the distribution factor is the ratio of the member stiffness to the total stiffness at the joint.
  3. Use the rule that the unbalanced moment is distributed in the opposite sense, and half is carried over to the far fixed end.
  4. Check the degree of indeterminacy of a frame before choosing the method; a hinged portal frame has degree one and a fixed portal frame has degree three.
  5. For sway frames, always introduce the extra lateral displacement unknown and write the horizontal equilibrium equation.
  6. In the slope-deflection method, set delta = 0 for non-sway frames and solve for the joint rotations first.
  7. Verify the final moments by checking that the sum of moments at each rigid joint is zero.
  8. Practise the analysis of a hinged portal frame under a horizontal load, because this standard problem appears repeatedly in examinations.

10. Conclusion

The analysis of frames is a step beyond the analysis of beams and trusses, because the rigid joints of a frame transmit bending moments and make the structure statically indeterminate. In this chapter we have studied the classification of frames as sway and non-sway types, the concept of the degree of indeterminacy, and the two most important analysis methods. The moment distribution method, which works by locking and successively releasing the joints, distributes the unbalanced moments in proportion to the member stiffnesses and uses the carry-over factor to transfer moments to the far ends. The slope-deflection method expresses the end moments analytically in terms of the joint rotations and the sway displacement, and solves them with the joint equilibrium equations. Together these methods enable the analysis of portal frames, continuous frames and multistorey building frames, and they form the foundation for modern computer-based matrix methods of structural analysis. A candidate who understands how a rigid joint distributes moments will find the design of reinforced concrete and steel frames a natural extension of this chapter.