Subject: Civil Engineering Chapter: Theory of Structures Topic: 5.6 Plastic Analysis
Plastic analysis, also called limit state analysis of steel structures, deals with the behaviour of structures beyond the elastic limit, where the material yields and forms plastic hinges that allow redistribution of moments. In the elastic analysis of a beam, the maximum bending moment is limited by the stress reaching the yield stress at the extreme fibre, and the load is kept within the elastic range. In plastic analysis, the full cross-section is allowed to become fully plastic, so that the beam can carry a much larger load than that which first causes yielding, until enough plastic hinges are formed to convert the structure into a mechanism. The load at which the mechanism forms is called the collapse load or the ultimate load.
The fundamental difference between elastic and plastic analysis lies in the idealised stress-strain curve. A mild steel stress-strain curve is assumed to be elastic-perfectly plastic, meaning that the stress rises linearly with strain up to the yield stress fy and then remains constant while the strain increases further. When the entire cross-section of a beam reaches the yield stress, the section is fully plastic, and it develops a plastic moment Mp equal to the yield stress multiplied by the plastic section modulus Z. The ratio of the plastic modulus to the elastic modulus is the shape factor, which is 1.5 for a rectangular section and 1.7 for an I-section.
In the examinations, plastic analysis questions deal with the plastic moment capacity of sections, the shape factors of common sections, the position and formation of plastic hinges, the plastic collapse of fixed beams and propped cantilevers, and the static and kinematic theorems of plastic collapse. The methods used are the statical method, based on the equilibrium conditions at the collapse mechanism, and the mechanism method, based on the principle of virtual work. Both give the same collapse load for the correct mechanism.
The plastic section modulus Z is defined as the first moment of the area about the plastic neutral axis, which divides the cross-section into equal areas so that the total tension force equals the total compression force. For a rectangular section of width b and depth d, the plastic neutral axis coincides with the centroidal axis and the plastic modulus is Z = bd2/4. The elastic section modulus of the same rectangle is Ze = bd2/6, so the shape factor for a rectangle is S = Z/Ze = 1.5.
The shape factor depends only on the geometry of the cross-section and is independent of the material. For an I-section, typical values of the shape factor lie between 1.14 and 1.20 depending on the proportions, and the standard value quoted in examinations is 1.15, though the common rounded value of 1.7 quoted in some texts refers to the ratio based on a different convention; the exact value for a wide flange is obtained from the plastic and elastic moduli. For a circular section the shape factor is 1.7, and for a diamond or triangular section it is 2.0.
Numerical example: A rectangular beam section 200 mm wide and 300 mm deep has a yield stress of 250 MPa. Find the plastic moment capacity. Solution: Plastic modulus Z = bd2/4 = 200 x 300 x 300 / 4 = 4.5 x 10^6 mm3. The plastic moment Mp = fy x Z = 250 x 4.5 x 10^6 = 1.125 x 10^9 Nmm = 1125 kNm. The elastic modulus Ze = bd2/6 = 3 x 10^6 mm3, and the yield moment My = fy x Ze = 750 kNm, so the shape factor is 1125/750 = 1.5.
A plastic hinge is a cross-section at which the full plastic moment has been reached and which can rotate under constant moment, allowing the rest of the structure to continue deforming. A plastic hinge forms at a point of maximum bending moment, which may occur under a concentrated load, at a fixed support, or at an intermediate point of contraflexure. A fixed support acts as a natural plastic hinge location because the maximum hogging moment occurs there. When the number of plastic hinges equals the degree of indeterminacy plus one, the structure becomes a mechanism and collapses.
For a fixed beam under a central point load, the first plastic hinge forms at the mid-span where the sagging moment is maximum, but the beam does not collapse, because the moment distribution changes and the support moments can still increase. Collapse occurs only when plastic hinges form at both ends and at the centre, three hinges in total, and at that instant the beam converts into a mechanism and the collapse load is reached. Although the general rule states that a structure of indeterminacy n needs n + 1 plastic hinges for a mechanism, a fixed beam under a single central point load collapses with just three hinges, because the beam mechanism for a mid-span load requires one hinge at each support and one at the load point.
For a propped cantilever under a UDL, the collapse occurs when two plastic hinges form, one at the fixed end and one at some point within the span where the sagging moment is maximum. The location of the interior hinge is found by differentiating the moment expression, and the collapse load is determined from the equilibrium of the mechanism. The plastic hinge at the interior is not necessarily at mid-span; for a UDL it forms at a distance x from the prop where the shear is zero.
Numerical example: A propped cantilever of span L carries a UDL w. Determine the collapse load in terms of the plastic moment Mp. Solution: Hinges form at the fixed end and at a point x from the prop. The collapse load is found by the statical method: the maximum sagging moment equals Mp and the hogging moment at the fixed end equals Mp. This gives wu L2 = 11.66 Mp, so wu = 11.66 Mp/L2. The exact result is wu = (Mp/L2)(8 + 4 sqrt 2) = 13.66 Mp/L2 for the correct geometry; the standard examination answer for a propped cantilever under UDL is wu = 11.66 Mp/L2.
Plastic collapse is governed by two fundamental theorems. The static or lower bound theorem states that a load which is in equilibrium with a set of bending moments nowhere exceeding the plastic moment is a lower bound on the collapse load; the highest such load is the true collapse load. The kinematic or upper bound theorem states that the load corresponding to any assumed mechanism, computed by equating the external work to the internal plastic work, is an upper bound on the collapse load; the lowest such load is the true collapse load. When a load satisfies both theorems it is the exact collapse load.
The mechanism method uses the principle of virtual work. For a small virtual displacement of the assumed mechanism, the external work done by the loads equals the internal work absorbed by the plastic hinges, which is the sum of Mp times the plastic rotation at each hinge. Equating these gives the collapse load directly. For a fixed beam under a central load, the mechanism has three hinges, each rotating by an angle theta or 2theta, and equating W times delta with Mp times the total rotation gives the collapse load Wu = 16Mp/L.
The statical method, also called the equilibrium method, draws the bending moment diagram of the structure at collapse by treating the hinges as releasing the moments and writing equilibrium from the reactions. The two theorems guarantee that the correct mechanism gives the unique collapse load, and in the examination the mechanism that gives the lowest collapse load is selected when several mechanisms are possible.
Numerical example: A fixed beam of span 6 m carries a central point load. If Mp = 120 kNm, find the collapse load. Solution: Using the mechanism method, the collapse load is Wu = 16Mp/L = 16 x 120 / 6 = 320 kN. Check by statics: at collapse, support moments and mid-span moment each equal Mp = 120 kNm, and the moment at mid-span from the load equals WL/4, so 120 + 120 = 6W/4, giving W = 320 kN.
| Section | Plastic modulus Z | Elastic modulus Ze | Shape factor |
|---|---|---|---|
| Rectangle b x d | bd2/4 | bd2/6 | 1.5 |
| Circle diameter d | d3/6 | pi d3/32 | 1.7 |
| Diamond / square on diagonal | d3/8 | d3/12 | 1.5 |
| Triangle | bh2/8 | bh2/24 | 2.0 |
| I-section (typical) | From section table | From section table | 1.14 - 1.20 |
| Beam | Mechanism | Collapse load |
|---|---|---|
| Fixed beam, central load | 3 hinges | Wu = 16Mp/L |
| Fixed beam, UDL | 3 hinges | wu = 16Mp/L2 |
| Propped cantilever, UDL | 2 hinges | wu = 11.66Mp/L2 |
| Propped cantilever, central load | 2 hinges | Wu = 11.66Mp/L |
| Simply supported, central load | 1 hinge | Wu = 4Mp/L |
| Continuous beam (n indeterminate) | n + 1 hinges | Depends on mechanism |
flowchart TD
A[Plastic Analysis] --> B[Plastic moment Mp]
A --> C[Shape factor]
A --> D[Plastic hinges]
A --> E[Collapse mechanisms]
A --> F[Theorems]
B --> B1[Mp = fy x Z]
B --> B2[Z = plastic section modulus]
C --> C1[S = Z/Ze]
C --> C2[Rectangle 1.5, circle 1.7]
D --> D1[Forms at maximum moment]
D --> D2[Fixed supports are hinges]
E --> E1[Number = indeterminacy + 1]
E --> E2[Mechanism method virtual work]
F --> F1[Static lower bound]
F --> F2[Kinematic upper bound]
The following diagrams show the fully plastic stress distribution of a rectangular section and the plastic hinge mechanism of a fixed beam.
Plastic analysis shows how the full strength of a steel section is mobilised at collapse and how the redistribution of moments increases the load carrying capacity of a statically indeterminate structure beyond its elastic limit. In this chapter we have studied the plastic section modulus, the plastic moment and the shape factors of the common sections, the formation of plastic hinges and the collapse mechanisms of beams, and the static and kinematic theorems of plastic collapse. The mechanism method based on virtual work, and the statical method based on equilibrium, both lead to the collapse load, and the two theorems guarantee that the correct mechanism gives the true answer. The standard results for the fixed beam, the propped cantilever and the simply supported beam provide quick solutions to examination problems. Plastic analysis is not merely an academic exercise; it is the basis of the limit state design of steel structures, in which members are proportioned so that the plastic moment capacity exceeds the ultimate bending moment with an adequate factor of safety. A clear grasp of the plastic hinge concept and the work equation therefore connects the theory of structures directly to practical structural design.