Subject: ICSE Class 10 Chemistry Chapter: Hall Heroult Process Topic: 7.7 Hall Heroult Process – Understand electrolytic extraction of aluminium
After the bauxite has been purified by the Baeyer process, the next task is to obtain the aluminium metal from the pure alumina. Since aluminium is a highly reactive metal, it cannot be reduced by carbon or hydrogen, and it must be extracted by electrolysis. The electrolytic method used to extract aluminium from alumina is called the Hall Heroult process, named after the two scientists who independently discovered it at about the same time.
The biggest difficulty in extracting aluminium is that pure alumina has a very high melting point of about 2050 degrees Celsius. Melting alumina alone would require an enormous amount of energy and would make the process very expensive. To overcome this problem, the purified alumina is dissolved in molten cryolite (Na3AlF6), which lowers the melting point and also makes the mixture conduct electricity. The molten mixture is then electrolysed in a special cell.
In this chapter we will study the construction of the electrolytic cell used in the Hall Heroult process, the reactions that take place at the cathode and the anode, and the reasons for adding cryolite and fluorspar. We will also learn about the reactions of the carbon anodes with the oxygen produced, and the properties and uses of the aluminium metal obtained.
The electrolytic cell used in the Hall Heroult process is a steel tank lined on the inside with carbon, which acts as the cathode. The carbon lining of the cell is connected to the negative terminal of the battery, and the molten aluminium collects at the bottom of the cell. The anode is made of a number of carbon blocks, called carbon rods or anodes, which are suspended into the molten mixture from the top and connected to the positive terminal.
The electrolyte consists of pure alumina dissolved in molten cryolite (Na3AlF6). A small amount of fluorspar (CaF2) is also added. The mixture is kept molten at a temperature of about 950 to 1000 degrees Celsius. At this temperature, the alumina dissolves in the molten cryolite, and the whole mixture becomes a good conductor of electricity.
The anode is made of carbon blocks, which get consumed during the process because the oxygen liberated at the anode reacts with the hot carbon to form carbon dioxide and carbon monoxide. The anodes therefore have to be replaced from time to time.
The cathode is the carbon lining of the steel tank. The molten aluminium collects at the bottom of the cell, from where it is tapped out from time to time. Because the aluminium is heavier than the molten electrolyte, it settles at the bottom and can be easily removed.
The cell operates at a temperature of about 950 to 1000 degrees Celsius, which is maintained by the heat produced by the passage of the electric current. The aluminium produced is of high purity, and it is tapped from the bottom of the cell, cast into ingots, and used for various purposes.
The electrolysis of the molten mixture of alumina in cryolite produces aluminium at the cathode and oxygen at the anode. The overall chemical reaction can be written as the decomposition of alumina into aluminium and oxygen, but the process takes place in two separate half reactions at the two electrodes.
Reaction at the cathode: At the cathode, the aluminium ions present in the molten mixture gain electrons and are reduced to aluminium metal. The reaction at the cathode is Al3+ + 3e- gives Al. The molten aluminium collects at the bottom of the cell.
Reaction at the anode: At the anode, the oxide ions lose electrons and are oxidised to oxygen gas. The reaction at the anode is 2O2- gives O2 + 4e-. The oxygen gas released at the anode reacts with the hot carbon anodes to form carbon dioxide and carbon monoxide, which escape as gases. This reaction is why the carbon anodes slowly burn away and must be replaced.
Overall reaction: The overall reaction of the Hall Heroult process is the decomposition of alumina into aluminium and oxygen: 2Al2O3 gives 4Al + 3O2. The aluminium formed at the cathode is collected, and the oxygen formed at the anode combines with the carbon of the anode and escapes.
The aluminium obtained by this process is about 99 percent pure. It can be further purified by electrolytic refining if required, but the aluminium obtained from the Hall Heroult process is pure enough for most purposes. The process is energy intensive, which is why aluminium smelters are located near cheap sources of electricity, such as hydroelectric power stations.
Cryolite (Na3AlF6) plays a very important role in the Hall Heroult process. Pure alumina melts at about 2050 degrees Celsius, which is too high for practical electrolysis. When alumina is dissolved in molten cryolite, the melting point of the mixture falls to about 950 to 1000 degrees Celsius, and the mixture becomes a good conductor of electricity. Cryolite thus acts as a solvent for alumina and lowers the temperature and energy requirement of the process.
Fluorspar (CaF2) is added in a small quantity to further reduce the melting point of the electrolyte mixture and to make it more conducting. Neither cryolite nor fluorspar is consumed during the electrolysis; they only help the process by lowering the melting point and increasing the conductivity.
Functions of cryolite and fluorspar: - They lower the melting point of the alumina from about 2050 C to about 950 C. - They make the molten mixture conduct electricity. - They are not consumed during the process. - They keep the electrolyte molten and allow smooth electrolysis.
The electrolytic extraction of aluminium is a good example of the extraction of a highly reactive metal. The key ideas to remember are that aluminium ions are reduced at the cathode to aluminium metal, oxide ions are oxidised at the anode to oxygen gas, the oxygen attacks the carbon anodes, and the cryolite lowers the melting point and aids conduction. With these ideas, the whole Hall Heroult process becomes easy to understand and reproduce in the examination.
Parts of the Hall Heroult cell and their functions:
| Part of the Cell | Material | Function |
|---|---|---|
| Anode | Carbon blocks | Positive electrode, burns away |
| Cathode | Carbon lining of steel tank | Negative electrode |
| Electrolyte | Alumina in molten cryolite | Source of aluminium ions |
| Steel tank | Steel lined with carbon | Holds the electrolyte |
Reactions and conditions in the Hall Heroult process:
| Point | Detail |
|---|---|
| Cathode reaction | Al3+ + 3e- gives Al |
| Anode reaction | 2O2- gives O2 + 4e- |
| Overall reaction | 2Al2O3 gives 4Al + 3O2 |
| Temperature | About 950 to 1000 C |
| Purpose of cryolite | Lowers melting point and increases conductivity |
| Aluminium collected at | Bottom of the cell as molten metal |
flowchart TD
A[Hall Heroult Process] --> B[Electrolytic extraction of aluminium]
B --> C[Pure alumina dissolved in molten cryolite]
C --> D[Electrolyte conducts electricity]
B --> E[Cathode carbon lining]
E --> F[Al3+ + 3e- gives Al]
B --> G[Anode carbon blocks]
G --> H[2O2- gives O2 + 4e-]
H --> I[Oxygen attacks carbon anode]
B --> J[Cryolite and fluorspar lower melting point]
F --> K[Molten aluminium tapped from bottom]
The first diagram shows the construction of the Hall Heroult electrolytic cell, and the second diagram shows the electrode reactions of the process.
The Hall Heroult process is the electrolytic method by which aluminium is extracted from pure alumina obtained through the Baeyer process. The purified alumina is dissolved in molten cryolite with a little fluorspar, which lowers the melting point and makes the mixture conduct electricity. On electrolysis, aluminium ions are reduced at the carbon-lined cathode to molten aluminium which collects at the bottom of the cell, while oxide ions are oxidised at the carbon anodes to oxygen gas, which attacks the anodes and consumes them. With a clear understanding of the cell, the electrode reactions, and the role of cryolite, we have now covered the complete extraction of aluminium, and we can move to the final chapter on alloys and amalgams, where metals are combined for special uses.