⚡ ICSE Class 9 Physics

Vernier Callipers

Start MCQ Practice →

Vernier Callipers

Subject: ICSE Class 9 Physics Chapter: Measurements and Experimentation Topic: 1.4 Vernier Callipers – Measure length using vernier callipers correctly

1. Introduction

The vernier callipers is a precision instrument used to measure the diameter of small objects, the thickness of sheets and the dimensions of tubes, with an accuracy of one tenth of a millimetre. It was invented by the French mathematician Pierre Vernier, and it uses the principle of the vernier scale, which is an auxiliary scale attached to the main scale to measure fractions of a division that the main scale alone cannot read. For an ICSE Class 9 student, the vernier callipers is one of the most important instruments in the chapter on measurements, because its reading is a compulsory part of the physics practical examination.

The instrument consists of a main scale graduated in centimetres and millimetres, a vernier scale that slides along the main scale, two fixed jaws and two movable jaws, and a thin metallic strip called the tail used for measuring the depth of a vessel. The upper jaws are used to measure the internal diameter of tubes and hollow objects, the lower jaws are used to measure the external diameter and thickness, and the tail is used to measure the depth of small vessels. The vernier scale can be locked in position with the help of a screw so that the jaws remain fixed while the reading is noted.

In this section we will study the parts of vernier callipers, the meaning of the vernier constant or least count, the correct method of taking a reading, and the calculation of the total reading from the main scale and vernier scale. We will also practise numerical examples in which the observed reading is calculated from the coinciding vernier division. This knowledge is essential for both the theory paper and the practical examination, since the vernier callipers is the instrument most frequently tested in the ICSE practical syllabus.

2. Parts of Vernier Callipers and the Vernier Constant

The main parts of vernier callipers are the main scale, the vernier scale, the fixed jaws, the movable jaws, the strip for measuring depth, and the locking screw. The main scale is fixed and is graduated in centimetres and millimetres, while the vernier scale slides along it. The lower jaws are used to measure the external diameter of a cylinder or the thickness of a sheet, the upper jaws are used to measure the internal diameter of a hollow tube, and the tail is used to measure the depth of a small vessel. The locking screw fixes the position of the jaws after the object has been gripped so that the reading can be taken conveniently.

The vernier constant, also called the least count of the vernier callipers, is the difference between one main scale division and one vernier scale division. In the common instrument, 1 main scale division is 1 mm and 10 vernier scale divisions are equal to 9 main scale divisions, so 1 vernier division is equal to 9/10 mm or 0.9 mm. The vernier constant is therefore 1 mm - 0.9 mm = 0.1 mm. The formula for the vernier constant is: Vernier constant = value of 1 main scale division divided by the number of divisions on the vernier scale, that is, 1 mm divided by 10 equals 0.1 mm.

The main scale division immediately to the left of the zero of the vernier scale gives the main scale reading, and the division of the vernier scale that exactly coincides with any division of the main scale gives the vernier scale reading. The total reading is obtained by the formula: Total reading = main scale reading + (vernier scale reading x vernier constant). This method allows the measurement of a length correct up to 0.1 mm, which is ten times more accurate than a metre rule.

3. Method of Measuring with Vernier Callipers

To measure the diameter of a small cylinder, the object is placed gently between the two lower jaws, and the jaws are tightened until they just touch the object without pressing it too hard. The locking screw is then tightened so that the position of the jaws does not change while the reading is being noted. The main scale reading is the reading of the main scale just to the left of the zero of the vernier scale, and the vernier scale reading is the number of the vernier division that coincides exactly with a division of the main scale.

The observed reading is calculated as the main scale reading plus the product of the vernier scale reading and the vernier constant. Before recording the final reading, the zero error of the instrument must be checked and applied, a concept that is studied in detail in a later section of this chapter. When the jaws are in contact and the zero of the vernier scale coincides exactly with the zero of the main scale, the instrument has no zero error and the observed reading is the true reading.

The measurement should be repeated at least three times, keeping the object at slightly different positions in the jaws, and the average of the readings is taken as the best value of the diameter. This averaging reduces the random errors caused by the observer. It is also important to hold the instrument in a vertical position while measuring the height of a block, and to measure the internal diameter of a tube with the upper jaws inserted properly inside the tube, so that the jaws touch the inner walls of the tube.

4. Numerical Examples on Vernier Callipers

Example 1: The main scale of vernier callipers has 10 divisions per centimetre. The vernier scale has 10 divisions that coincide with 9 divisions of the main scale. Find the least count.

Solution: Value of 1 main scale division = 1 cm / 10 = 0.1 cm = 1 mm. Least count = value of 1 MSD / number of vernier divisions = 1 mm / 10 = 0.1 mm = 0.01 cm. (Ans)

Example 2: While measuring the diameter of a small cylinder, the main scale reading is 2.5 cm and the 6th vernier division coincides with a main scale division. Find the observed reading if the least count is 0.01 cm.

Solution: Observed reading = MSR + (vernier division x least count) = 2.5 cm + (6 x 0.01 cm) = 2.5 cm + 0.06 cm = 2.56 cm. (Ans)

Example 3: The vernier scale of an instrument has 20 divisions equal to 19 main scale divisions, each main scale division being 1 mm. Find the least count and the observed reading when the main scale reading is 1.2 cm and the 15th vernier division coincides.

Solution: Least count = 1 mm / 20 = 0.05 mm = 0.005 cm. Observed reading = 1.2 cm + (15 x 0.005 cm) = 1.2 cm + 0.075 cm = 1.275 cm. (Ans)

5. Quick Revision Tables

Table 1: Parts of Vernier Callipers and Their Uses

Part Function
Main scale Graduated in cm and mm; gives the main scale reading
Vernier scale Sliding auxiliary scale; gives the fractional part
Lower jaws Measure external diameter and thickness
Upper jaws Measure internal diameter of hollow tubes
Tail strip Measure the depth of small vessels
Locking screw Locks the jaws so the reading does not change

Table 2: Steps in Reading Vernier Callipers

Step Procedure
1 Place the object gently between the lower jaws
2 Tighten the jaws till they just touch the object
3 Lock the jaws with the locking screw
4 Note the main scale reading left of the vernier zero
5 Note the coinciding vernier division
6 Total reading = MSR + (vernier division x least count)
7 Apply the zero error if present
8 Repeat and take the average of the readings

6. Mind Map

flowchart TD
    A[Vernier Callipers] --> B[Parts]
    A --> C[Least count]
    A --> D[Method of measurement]
    A --> E[Reading calculation]
    B --> B1[Main scale]
    B --> B2[Vernier scale]
    B --> B3[Jaws upper and lower]
    B --> B4[Tail for depth]
    C --> C1[1 MSD / No. of vernier divisions]
    C --> C2[Usually 0.1 mm]
    D --> D1[Grip object gently]
    D --> D2[Lock the jaws]
    D --> D3[Note MSR and vernier division]
    E --> E1[MSR + vernier division x LC]
    E --> E2[Apply zero error]

7. Important Diagrams (SVG)

The following diagrams show the parts of vernier callipers and the method of taking a reading.

Parts of Vernier Callipers MAIN SCALE graduated in cm and mm VERNIER SCALE slides along main scale LOWER JAWS UPPER JAWS External diameter, thickness Internal diameter of tube TAIL for depth LOCKING SCREW Least count = 1 MSD / number of vernier divisions Standard value = 0.1 mm = 0.01 cm Golden Rule The vernier scale measures the fraction of the main scale division that lies left of its zero.

Reading Vernier Callipers Main scale (cm) 1 cm 2 3 4 5 6 VERNIER SCALE (10 divisions) coinciding division 6 Main scale reading = 3.5 cm Vernier reading = 6 x 0.01 cm = 0.06 cm Observed reading = 3.5 + 0.06 = 3.56 cm Golden Rule Find the one vernier division that exactly coincides with any main scale division; that is the vernier reading.

8. Common Mistakes

  1. Many students record the main scale reading to the right of the vernier zero instead of the left, which changes the reading by a full division.
  2. A frequent error is to multiply the vernier scale reading by the least count in millimetres and add it to a main scale reading in centimetres, mixing up the units.
  3. Students often take the first vernier division that is near a main scale line rather than the one that exactly coincides, giving a wrong vernier reading.
  4. Some students press the object too hard between the jaws, which deforms the object and gives a reading smaller than the true value.
  5. A common mistake is to forget to check the zero error of the instrument before use, so the final reading contains an error of up to the least count.
  6. Many students measure the external diameter with the upper jaws instead of the lower jaws, or fail to insert the upper jaws properly when measuring internal diameter.
  7. Students often neglect to take repeated readings and the average, so their single reading is affected by random error.
  8. Some students forget that the tail measures depth and not length, and misuse it while measuring the height of a block.

9. Exam Tips

  1. Learn to state the least count of vernier callipers both as 0.1 mm and as 0.01 cm, because either form may be required in the answer.
  2. Follow the reading formula strictly: total reading = main scale reading + (vernier division x least count), and then apply the zero error.
  3. Practise the calculation of the least count from data such as 10 vernier divisions equal to 9 main scale divisions, a favourite numerical in the paper.
  4. Remember that the internal diameter is measured with the upper jaws and the external diameter with the lower jaws, a point frequently asked in one-mark questions.
  5. While drawing the labelled diagram of vernier callipers in the practical copy, mark the main scale, vernier scale, both jaws, tail and locking screw.
  6. In numericals, always check whether the least count is to be taken in millimetres or centimetres before multiplying with the vernier division.
  7. Revise the coincidence rule: only one vernier division coincides exactly with a main scale division at any position of the jaws.

10. Conclusion

The vernier callipers is the classic example of how a simple auxiliary scale can increase the accuracy of a measuring instrument tenfold. In this section we have studied the parts of vernier callipers, the meaning of the vernier constant, the correct method of gripping the object and locking the jaws, and the formula for calculating the total reading. We have also practised numerical problems involving the least count and the observed reading, and understood why the vernier division that exactly coincides with a main scale division gives the fractional part of the reading. The vernier callipers is directly used in the ICSE practical examination to measure the diameter of a cylinder and the thickness of a sheet, and it forms the basis of the concept of zero error studied in the next section. By memorising the parts, the least count and the reading formula, and by practising the numericals, a student can perform the vernier callipers experiment confidently and score full marks in both theory and practical examinations.